Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-29660664

ABSTRACT

Hepcidin-25 peptide is a biomarker which is known to have considerable clinical potential for diagnosing iron-related diseases. Developing analytical methods for the absolute quantification of hepcidin is still a real challenge, however, due to the sensitivity, specificity and reproducibility issues involved. In this study, we compare and discuss two MS-based assays for quantifying hepcidin, which differ only in terms of the type of liquid chromatography (nano LC/MS versus standard LC/MS) involved. The same sample preparation, the same internal standards and the same MS analyzer were used with both approaches. In the field of proteomics, nano LC chromatography is generally known to be more sensitive and less robust than standard LC methods. In this study, we established that the performances of the standard LC method are equivalent to those of our previously developed nano LC method. Although the analytical performances were very similar in both cases. The standard-flow platform therefore provides the more suitable alternative for accurately determining hepcidin in clinical settings.


Subject(s)
Chromatography, High Pressure Liquid/methods , Hepcidins/blood , Mass Spectrometry/methods , Nanotechnology/methods , Female , Hepcidins/isolation & purification , Humans , Limit of Detection , Linear Models , Male , Middle Aged , Reproducibility of Results
2.
Crit Rev Clin Lab Sci ; 54(3): 173-184, 2017 05.
Article in English | MEDLINE | ID: mdl-28393579

ABSTRACT

Although dried blood spot (DBS) sampling methods have been used since the 1960s, they have recently attracted renewed interest because of the development of new clinical applications. In addition to their other advantages, DBS methods can now be used to quantify many blood proteins using the latest highly sensitive and robust, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) approaches such as multiple reaction monitoring. The DBS blood sampling approach could provide a useful alternative means of conducting blood sampling for routine clinical purposes and patients' follow-up. In this review, we examine the current use of DBS for LC-MS/MS protein quantification in clinical settings and discuss potential clinical applications.


Subject(s)
Dried Blood Spot Testing , Mass Spectrometry , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...