J Ultrasound ; 24(4): 411-416, 2021 Dec.
Article in English | MEDLINE | ID: mdl-32358646

ABSTRACT

PURPOSE: We have focused on the two-dimensional (B-mode) and the time-motion (M-mode) analysis of the zone of apposition to determine the reliability of diaphragm ultrasonography in the clinical environment. METHODS: Ten healthy volunteers were enrolled and studied by three operators with different skills in ultrasonography. For every volunteer, each operator acquired three images of the diaphragm for each side, both in B-mode and in M-mode. Then a fourth operator calculated the thickening fraction (TF), by means of the formula TF = (TEI - TEE)/TEE (TEI is the thickness at end inspiration and TEE the thickness at end expiration). Afterwards, intraclass correlation coefficients (ICCs) were computed on TF to establish reproducibility and repeatability both in the B- and M-modes. A Coefficient of Repeatability or repeatability (CR) ≤ 0.3 was considered acceptable. RESULTS: Both B-mode (CRs 0.16-0.26) and M-mode (CRs 0.10-0.15) were sufficiently repeatable to assess TF, except for the less experienced operator (CRs B-Mode 0.20-0.32). Reproducibility was moderate to good between operators with CRs much narrower for the M-Mode (0.13-0.14). CONCLUSIONS: The results of our study have shown that diaphragm ultrasound is repeatable and reproducible when carried out by a radiologist or an intensivist with a basic curriculum in ultrasonography. The method is more accurate when using the M-mode for less experienced operators, and in this case, repeatability and reproducibility are not sufficient to make clinical decisions. No TF value lower than 36% was obtained using both techniques. This suggests the existence of a cut-off value that could be used as an initial tool to discriminate healthy subjects from those affected by diaphragmatic dysfunction. CLINICAL TRIAL REGISTRATION: EUDRACT 2015-004635-12.


Subject(s)
Diaphragm , Diaphragm/diagnostic imaging , Healthy Volunteers , Humans , Reproducibility of Results , Ultrasonography
2.
Trials ; 19(1): 135, 2018 Feb 21.
Article in English | MEDLINE | ID: mdl-29467022

ABSTRACT

BACKGROUND: The extensive use of neuromuscular blocking agents (NMBAs) during surgical procedures still leads to potential residual paralyzing effects in the postoperative period. Indeed, neuromuscular monitoring in an intra-operative setting is strongly advocated. Acetylcholinesterase inhibitors can reverse muscle block, but their short half-life may lead to residual curarization in the ward, especially when intermediate or long-acting NMBAs have been administered. Sugammadex is the first selective reversal drug for steroidal NMBAs; it has been shown to give full and rapid recovery of muscle strength, thus minimizing the occurrence of residual curarization. Acceleromyography of the adductor pollicis is the gold standard for detecting residual curarization, but it cannot be carried out on conscious patients. Ultrasonography of diaphragm thickness may reveal residual effects of NMBAs in conscious patients. METHODS/DESIGN: This prospective, double-blind, single-center randomized controlled study will enroll patients (of American Society of Anesthesiologists physical status I-II, aged 18-80 years) who will be scheduled to undergo deep neuromuscular block with rocuronium for ear, nose, or throat surgery. The study's primary objective will be to compare the effects of neostigmine and sugammadex on postoperative residual curarization using two different tools: diaphragm ultrasonography and acceleromyography of the adductor pollicis. Patients will be extubated when the train-of-four ratio is > 0.9. Diaphragm ultrasonography will be used to evaluate the thickening fraction, which is the difference between the end expiratory thickness and the end inspiratory thickness, normalized to the end expiratory thickness. Ultrasonography will be performed before the initiation of general anesthesia, before extubation, and 10 and 30 min after discharging patients from the operating room. The secondary objective will be to compare the incidence of postoperative complications due to residual neuromuscular block between patients who receive neostigmine and those who receive sugammadex. DISCUSSION: Postoperative residual curarization is a topic of paramount importance, because its occurrence can cause complications and increase the length of stay in hospital and the related costs. Diaphragm ultrasound assessment may become a bedside integrative tool in the neuromuscular monitoring field to detect concealed residual curarization in surgical patients who have received paralyzing agents. TRIAL REGISTRATION: EudraCT, 2013-004787-62. Registered on 18 June 2014, as "Evaluation of muscle function recovery after deep neuromuscular blockade by acceleromyography of the adductor pollicis or diaphragmatic echography: comparison between sugammadex and neostigmine." ClinicalTrials.gov, NCT02698969 . Registered on 15 February 2016, as "Recovery of Muscle Function After Deep Neuromuscular Block by Means of Diaphragm Ultrasonography and Adductor Pollicis Acceleromyography: Comparison of Neostigmine vs. Sugammadex as Reversal Drugs."


Subject(s)
Cholinesterase Inhibitors/therapeutic use , Delayed Emergence from Anesthesia/diagnostic imaging , Delayed Emergence from Anesthesia/drug therapy , Diaphragm/drug effects , Diaphragm/diagnostic imaging , Myography/methods , Neostigmine/therapeutic use , Neuromuscular Blockade/methods , Sugammadex/therapeutic use , Ultrasonography/methods , Adolescent , Adult , Aged , Aged, 80 and over , Cholinesterase Inhibitors/adverse effects , Delayed Emergence from Anesthesia/physiopathology , Double-Blind Method , Female , Humans , Italy , Male , Middle Aged , Neostigmine/adverse effects , Neuromuscular Blockade/adverse effects , Predictive Value of Tests , Prospective Studies , Randomized Controlled Trials as Topic , Recovery of Function , Sugammadex/adverse effects , Time Factors , Treatment Outcome , Young Adult
3.
ASAIO J ; 64(2): 175-182, 2018.
Article in English | MEDLINE | ID: mdl-28777134

ABSTRACT

Transcranial Doppler (TCD) is able to detect cerebral hemodynamic changes in real-time. Impairment of cerebral blood flow during veno-arterial (VA) extracorporeal membrane oxygenation (ECMO) treatment is referred to in the literature. Several cerebrovascular complications can affect VA ECMO patients, eventually leading to brain death (BD). Transcranial Doppler is a worldwide accepted technique for cerebral circulatory arrest (CCA) diagnosis for BD confirmation, and in Italy, it is mandatory in certain clinical conditions. Nowadays, no data have been published on the use of TCD as a confirmation test in VA ECMO patients evolved to BD. The aim of our study was to investigate the feasibility of TCD in CCA diagnosis during VA ECMO treatment. Thirty-two TCD examinations, performed in 25 patients on VA ECMO, were retrospectively analyzed, and factors that could be responsible for TCD waveforms abnormalities were reviewed. Differences in TCD patterns were detected depending on values of left ventricular ejection fraction and the absence or presence of intraaortic balloon pump (IABP). Four categories of different TCD patterns were then identified. In five BD patients, diagnostic CCA patterns in all cerebral arteries were identified by TCD. Our data suggest that cerebral hemodynamic changes due to both residual cardiac function and the effects of IABP can be detected by TCD in VA ECMO patients. In the case of BD, TCD seems to be a reliable instrumental test for CCA diagnosis in patients on VA ECMO when a pulsatile flow is maintained (native or IABP support).


Subject(s)
Brain Death/diagnostic imaging , Extracorporeal Membrane Oxygenation , Ultrasonography, Doppler, Transcranial/methods , Adult , Brain/blood supply , Brain/diagnostic imaging , Cerebrovascular Circulation/physiology , Female , Humans , Male , Middle Aged , Retrospective Studies