Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Med (Hagerstown) ; 24(9): 625-630, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37605954

ABSTRACT

AIMS: In Italy, 12-month survival in the general population between 90 and 94 years old is 26%. In very old patients, the benefit of pacemaker implantation in terms of quality and duration of life is unclear. The aim of our study was to analyse clinical characteristics, outcome and factors associated with survival in patients at least 90 years old at the time of the first pacemaker implant. METHODS: Clinical parameters, device characteristics, survival and predictors of outcome in patients at least 90 years old treated with a pacemaker in our centre in 2019-2020 were evaluated. RESULTS: Among the 554 patients undergoing pacemaker implantation in our centre during the study interval, 69 (12%) were at least 90 years old; a complete/advanced atrioventricular block was present in 65%. A cardiological comorbidity (excluding atrial fibrillation) was present in 22 patients (32%). Oncological, pulmonary and neurological comorbidities were present in 12 (17%), 19 (28%) and 32 (46%), respectively. Renal impairment was present in 25 patients (36%). After pacemaker implantation, a pneumothorax developed in two patients and lead dislodgment in one. During follow-up (median 17 months, interquartile range: 13-24), 32 patients died (46%), with a 12-month mortality probability of 24.6%. At multivariate analysis, the presence of oncological (hazard ratio (HR) 5.31; P < 0.001) and neurological (HR 6.44; P < 0.001) comorbidities was associated with mortality. Truncating the outcome at 6 months, renal impairment (HR 8.01; P = 0.003), anticoagulant therapy (HR 8.14; P = 0.003), oncological comorbidities (HR 14.1; P < 0.001) and left ventricular function (5% increase of left ventricular ejection fraction: HR 0.66; P < 0.001) were significantly associated with outcome. CONCLUSION: At our centre, patients at least 90 years old underwent pacemaker implantation mainly for advanced atrioventricular block. One-year survival was excellent, even better than expected in the general population.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Cardiology , Pacemaker, Artificial , Humans , Aged, 80 and over , Atrioventricular Block/therapy , Italy/epidemiology , Pacemaker, Artificial/adverse effects
2.
Eur J Intern Med ; 115: 1-9, 2023 09.
Article in English | MEDLINE | ID: mdl-37076404

ABSTRACT

In this review we focus on heart failure (HF) which, as known, is associated with a substantial risk of hospitalizations and adverse cardiovascular outcomes, including death. In recent years, systems to monitor cardiac function and patient parameters have been developed with the aim to detect subclinical pathophysiological changes that precede worsening HF. Several patient-specific parameters can be remotely monitored through cardiac implantable electronic devices (CIED) and can be combined in multiparametric scores predicting patients' risk of worsening HF with good sensitivity and moderate specificity. Early patient management at the time of pre-clinical alerts remotely transmitted by CIEDs to physicians might prevent hospitalizations. However, it is not clear yet which is the best diagnostic pathway for HF patients after a CIED alert, which kind of medications should be changed or escalated, and in which case in-hospital visits or in-hospital admissions are required. Finally, the specific role of healthcare professionals involved in HF patient management under remote monitoring is still matter of definition. We analyzed recent data on multiparametric monitoring of patients with HF through CIEDs. We provided practical insights on how to timely manage CIED alarms with the aim to prevent worsening HF. We also discussed the role of biomarkers and thoracic echo in this context, and potential organizational models including multidisciplinary teams for remote care of HF patients with CIEDs.


Subject(s)
Defibrillators, Implantable , Heart Failure , Humans , Heart Failure/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...