Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Diabetes Sci Technol ; 14(6): 1095-1103, 2020 11.
Article in English | MEDLINE | ID: mdl-31640411

ABSTRACT

BACKGROUND: We evaluated the reproducibility of office-based flicker electroretinography (ERG) in patients with nonproliferative diabetic retinopathy (NPDR). METHODS: An observational study was conducted in which ultra-widefield fluorescein angiography (UWF-FA) was performed on 20 patients with mild-to-moderate NPDR; images were graded by the Fundus Photography Reading Center (Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, WI, USA). Fixed- and multi-luminance flicker ERG was repeated four times (greater than or equal to seven days apart). Recording consistency was assessed using intra-class correlation coefficients (ICCs), coefficients of variation, and Pearson correlations. RESULTS: 82.5% and 17.5% of eyes had mild and moderate NPDR using UWF-FA; 90% of the angiograms were given a high confidence grade. Fixed-luminance phase values were highly reproducible (ICC: 0.949; P < .001). There was a significant negative correlation between fixed-luminance phase and log-corrected ischemic index values (-0.426; P = .015). CONCLUSIONS: Office-based, fixed-luminance phase values are highly reproducible and negatively correlate with retinal ischemia in NPDR, suggesting that global retinal dysfunction may be reliably quantified early in patients with diabetes.


Subject(s)
Diabetic Retinopathy/diagnosis , Electroretinography , Retina/physiopathology , Adult , Aged , Diabetic Retinopathy/physiopathology , Female , Fluorescein Angiography , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index
2.
Doc Ophthalmol ; 139(3): 185-195, 2019 12.
Article in English | MEDLINE | ID: mdl-31312944

ABSTRACT

PURPOSE: To evaluate the repeatability of the steady-state pattern electroretinogram (PERG) and full-field flicker electroretinogram (Flicker ERG) protocols, delivered by the office-based Neuro Optic Vision Assessment (NOVA)™ testing platform, in healthy subjects. METHODS: Healthy individuals underwent PERG (16° and 24°) and Flicker ERG [fixed luminance (FL) and multi-luminance (ML)] testing protocols. Test-retest repeatability of protocols was calculated using intra-class correlation coefficients (ICC). Reference values of the parameters of the aforementioned tests were also calculated. RESULTS: The ICCs for the PERG parameters ranged from 0.793 to 0.911 (p < 0.001). The ICCs for the Flicker ERG parameters ranged from 0.968 to 0.994 (p < 0.001). A linear regression analysis was applied to assess the impact of age on ERG responses. Age had a significant impact on all PERG parameters (16° or 24°). The phase response of the FL Flicker ERG significantly decreased with age (ß = - 0.837, p ≤ 0.001). The FL Flicker ERG Magnitude was also impacted with a significant quadratic effect of age (ß = - 0.0047, p = 0.0004). Similarly, the Phase Area Under the Curve (Phase AUC) of the ML Flicker ERG significantly declined with age (ß = - 0.007, p = 0.009), and the impact on the Magnitude AUC was significant as well, with a negative quadratic age effect. CONCLUSIONS: The PERG and Flicker ERG protocols, delivered by an office-based testing platform, were shown to have good-to-excellent test-retest repeatability when tests were performed in the same order and in immediate succession.


Subject(s)
Electroretinography/standards , Retina/physiology , Adult , Aged , Aged, 80 and over , Aging/physiology , Cross-Sectional Studies , Electroretinography/methods , Female , Healthy Volunteers , Humans , Male , Middle Aged , Prospective Studies , Reference Values , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...