Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Appl Lab Med ; 5(2): 290-299, 2020 03 01.
Article in English | MEDLINE | ID: mdl-32445383

ABSTRACT

BACKGROUND: Asfotase alfa (STRENSIQ®, Alexion Pharmaceuticals, Inc.) is the only approved treatment for patients with pediatric-onset hypophosphatasia, a disease caused by a mutation in the tissue-nonspecific alkaline phosphatase (TNSALP) gene. ALP is often used as signaling system in routine immunoassays. Because asfotase alfa contains the active site of the full ALP enzyme, it can catalyze the substrate as the antibody-conjugated ALP would within an assay. Therefore, its presence in a treated patient's sample may generate false positive or false negative results. We investigated whether the presence of asfotase alfa within a sample induced interference in immunoassays that utilize ALP or alternative detection systems. METHODS: Asfotase alfa was added to samples at concentrations from 0.08-5 µg/mL and analysed on various immunoassays following manufacturer's instructions. RESULTS: Asfotase alfa was detected in all ALP assays but ALKP1 (RayBiotech). We observed no changes in normetanephrine and noradrenaline (IBL) at any asfotase alfa concentration. However, asfotase alfa notably interfered in an oxytocin (ENZO) assay in nonextracted samples. Extraction using a C18 column eliminated the interference. No interference was observed on automated analyzers using alternative detection system (COBAS fT4 and TSH; Advia Centaur FSH, fT4; Architect LH; FSH). Immulite 2000 fT4, TSH, testosterone and hCG (ALP-based) showed no interference. However, the presence of asfotase alfa resulted in a dose-dependent increase of Troponin I signal. CONCLUSION: The presence of asfotase alfa must be taken into consideration when analyzing blood samples in treated patients to avoid any risk of misinterpretation of false positive/negative results. It is essential that assays be tested for this possible interference.


Subject(s)
Alkaline Phosphatase/blood , Hypophosphatasia/blood , Hypophosphatasia/diagnosis , Immunoassay/methods , Immunoassay/standards , Immunoglobulin G/adverse effects , Recombinant Fusion Proteins/adverse effects , Alkaline Phosphatase/adverse effects , Alkaline Phosphatase/pharmacokinetics , Analysis of Variance , Biomarkers/blood , Enzyme Activation , False Positive Reactions , Humans , Hypophosphatasia/etiology , Recombinant Fusion Proteins/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...