Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 15(13)2022 Jul 04.
Article in English | MEDLINE | ID: mdl-35806804

ABSTRACT

The article presents research on using the adsorption process of aldrin (a chloro-organic pesticide that most often occurs in the environment near expired pesticide burials). The research used three sorbents: two activated carbons and compost from sewage sludge as a low-cost sorbent. Obtained adsorption isotherms belong to the L group according to the Giles classification. The test results and their analysis confirm that the IZO application facilitates the analysis of the adsorption process. The study results also confirm that compost can be a cost-effective alternative to commercial activated carbons to build barriers protecting the environment against existing leaking expired pesticide burials.

2.
Sensors (Basel) ; 22(8)2022 Apr 18.
Article in English | MEDLINE | ID: mdl-35459082

ABSTRACT

Static and dynamic methods can be used to assess the way a foot is loaded. The research question is how the pressure on the feet would vary depending on walking/running speed. This study involved 20 healthy volunteers. Dynamic measurement of foot pressure was performed using the Ortopiezometr at normal, slow, and fast paces of walking. Obtained data underwent analysis in a "Steps" program. Based on the median, the power generated by the sensors during the entire stride period is the highest during a fast walk, whereas based on the average; a walk or slow walk prevails. During a fast walk, the difference between the mean and the median of the stride period is the smallest. Regardless of the pace of gait, the energy released per unit time does not depend on the paces of the volunteers' gaits. Conclusions: Ortopiezometr is a feasible tool for the dynamic measurement of foot pressure. For investigations on walking motions, the plantar pressure analysis system, which uses the power generated on sensors installed in the insoles of shoes, is an alternative to force or energy measurements. Regardless of the pace of the walk, the amounts of pressure applied to the foot during step are similar among healthy volunteers.


Subject(s)
Foot , Walking Speed , Biomechanical Phenomena , Gait , Healthy Volunteers , Humans , Shoes , Walking
3.
Materials (Basel) ; 14(15)2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34361386

ABSTRACT

The purpose of this paper is to present the IZO application that calculates and visualizes coefficients of adsorption isotherms according to Freundlich, Langmuir, and BET in a classic and linear system, in a simple communicative way. The application also calculates the working time of the adsorption bed based on the transformation of the mass balance equation, and according to the Zuchowicki, Zabiezinski, Tichonow, and the Bohart-Adams equations. The laboratory tests of the adsorption process of leachate from a municipal landfill on selected active coals ORGANOSORB 10, DESOTEK, and BA-10, were conducted to check the program for accuracy. Results of tests confirm that the linearization method of the calculation of adsorption isotherms coefficients, used in the IZO application, gives sufficient accuracy and may be used as an alternative of, e.g., the nonlinear estimation method.

4.
Med Sci Monit ; 25: 4916-4922, 2019 Jul 03.
Article in English | MEDLINE | ID: mdl-31266932

ABSTRACT

BACKGROUND There are many methods of dynamic analysis of foot loading, however, we still need a simple, easily applicable system for foot plantar pressure analysis. In this study we asked the question: "Can a new system for foot evaluation, the ITE System, provide a good quantitative dynamic foot pressure analysis? Can it be used in clinical practice?". MATERIAL AND METHODS Twenty healthy volunteers, 8 females and 12 males, aged 20 to 25 years old took part in this study. Normal static foot loading was tested using a typical pedobarographic platform, followed by a dynamic analysis using the foot-pressure ITE System. A new algorithm for data analysis (from 8 sensors) was proposed. RESULTS The sum of all maximal values from sensors was 11.71 N mean, with relatively low standard deviation (SD) of 1.81. Loading of sensor 1 (heel) was the highest - on average 29.84%. Sensor 2 (medial midfoot) received the lowest loading - normal range for this segment would be 0-4%. The manner of loading heel/toes, dynamics of changes in loading during gait was quite diverse; when analyzing courses of changes on sensors, 4 gait patterns were observed. CONCLUSIONS Use of the ITE System creates a new possibility for dynamic foot evaluation, drawing from pedobarography and methods of gait analysis. The proposed data analysis algorithm is simple and can be applied in all cases. Normally, 30% of the sum of all pressures during stance phase falls on the rearfoot; 39% falls on forefoot.


Subject(s)
Fasciitis, Plantar/physiopathology , Gait Analysis/methods , Walking/physiology , Adult , Algorithms , Biomechanical Phenomena , Female , Foot , Gait , Gait Analysis/instrumentation , Heel , Humans , Male , Pressure , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL
...