1.
Dent J (Basel) ; 12(2)2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38392246

ABSTRACT

This exploratory case series clinically and histologically investigated the performance of allogeneic cancellous freeze-dried bone allograft (FDBA) bone blocks (Maxgraft®) for the lateral augmentation of local alveolar defects in the posterior maxilla as part of two-staged implant therapy. Five patients receiving eight implants 5 months after block augmentation with a follow-up period of up to 3 years were documented and analyzed. Horizontal alveolar dimensions before and 5 months after block augmentation were quantified using CBCT. Radiographic marginal bone level changes were quantified at implant placement, loading, and 1 year post-placement. Graft integration and resorption were histologically qualitatively evaluated from core biopsies retrieved at implant placement. Block augmentations resulted in a pronounced horizontal median bone gain of 7.0 (5.5 to 7.8) mm. Marginal implant bone levels in block-augmented bone remained constant over the 1 year follow-up period. Block grafts appeared histologically well integrated. Histologic analysis also revealed signs of progressive resorption and new bone formation at the lateral aspects of the grafts. The results of this case series support using Maxgraft® cancellous FDBA blocks as suitable materials for the lateral augmentation of local alveolar defects.

2.
J Adv Prosthodont ; 15(2): 55-62, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37153006

ABSTRACT

PURPOSE: The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS: 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS: The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson's Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION: All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision.

SELECTION OF CITATIONS
SEARCH DETAIL
...