Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35564426

ABSTRACT

Certified disposable respirators afford important protection from hazardous aerosols but lose performance as they are worn. This study examines the effect of wear time on filtration efficiency. Disposable respirators were worn by CSIRO staff over a period of 4 weeks in early 2020. Participants wore the respirator masks for given times up to eight hours whilst working in laboratory/office environments. At that time COVID-19 precautions required staff to wear surgical (or other) masks and increase use of hand sanitizer from dispenser stations. Results obtained from a test group of ten individuals without health preconditions show an increasing number of masks failing with wear time, while the remainder continue to perform nearly unaffected for up to 8 h. Some masks were found to retain filtration performance better than others, possibly due to the type of challenge they were subjected to by the wearer. However, the rate and extent of decay are expected to differ between environments since there are many contributing factors and properties of the aerosol challenge cannot be controlled in a live trial. Penetration and variability increased during wear; the longer the wear time, the more deleterious to particle removal, particularly after approximately 2 h of wear. This behavior is captured in a descriptive statistical model based on results from a trial with this test group. The effectiveness of the masks in preventing the penetration of KCl particles was determined before and after wearing, with the analysis focusing on the most penetrating particles in a size range of 0.3-0.5 µm diameter where respirator masks are most vulnerable. The basic elements of the study, including the approach to filter testing and sample sanitization, are broadly applicable. Conclusions also have applicability to typical commercially available single-use respirator masks manufactured from melt blown polypropylene as they are reliant on the same physical principles for particle capture and electrostatic enhancement was comparable for the particle size range used for detection.


Subject(s)
COVID-19 , Respiratory Protective Devices , Aerosols/analysis , COVID-19/prevention & control , Filtration , Humans , Masks , Particle Size , Static Electricity
2.
Article in English | MEDLINE | ID: mdl-35055461

ABSTRACT

The potential for alcoholic vapors emitted by common sanitizing treatments to deteriorate the (electrostatic) filtration performance of disposable respirator masks has been investigated. Reports in the literature and some standard test methods provide a confusing and ambiguous picture concerning the relevance of this effect. Four different types of exposure were investigated in this study to clarify the effect of alcoholic vapor emissions on respirator masks. These included exposure to saturated vapors, use of hand sanitizers, cleaning of table surfaces and sanitization of masks by spraying them with alcohol-containing solutions. Methods employed were designed to be as real-world oriented as possible while remaining reproducible. Filtration performance and deterioration effects on exposure to the different treatments were determined on three different types of certified commercial respirator masks-a P2 and two KN95 masks. This study provides substantial evidence that disposable respirator masks with an accepted performance rating are seriously compromised from an exposure to saturated alcoholic vapors, can tolerate a one-off spray treatment with an alcoholic solution and retain their attested protection under the influence of alcoholic vapors from the use of hand sanitizer or spray sanitizer. Considering the range of vastly different outcomes obtained from the four treatments investigated, it seems prudent to assess in each case the specific effects of alcoholic solution treatments and vapors on respirator masks before use.


Subject(s)
Occupational Exposure , Respiratory Protective Devices , Filtration , Masks , Ventilators, Mechanical
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 117: 598-603, 2014 Jan 03.
Article in English | MEDLINE | ID: mdl-24103230

ABSTRACT

The realized mechanical properties of CNT macrostructures such as webs and yarns remain significantly lower than those of the individual CNTs. Structural changes induced by thermal annealing under inert atmosphere were assessed using Raman spectroscopy. Annealing above 1000 °C resulted in a marked decrease in the D/G ratio which can be attributed to an increase in the crystallite size or the distance between defects. The band component parameters obtained by spectral deconvolution reveal that the D band peak maximum shifts to slightly higher energy with increased annealing temperature. In contrast, the energy of the G band did not change. The full widths at half height (FWHH) of the D and G bands are seen to decrease with increasing annealing temperature. The tensile properties of the yarns have been investigated and it was found that the yarn tenacity did not improve with these structural changes. The effect of impurities in the annealing system such as oxygen, adsorbed water or organic surface contamination was also investigated.


Subject(s)
Nanotechnology , Nanotubes, Carbon/chemistry , Spectrum Analysis, Raman , Temperature , Adsorption , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL