Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Animals (Basel) ; 14(10)2024 May 08.
Article in English | MEDLINE | ID: mdl-38791627

ABSTRACT

(1) Background: the erythrocyte sedimentation rate (ESR) has been reported to increase in some infectious or inflammatory diseases in dogs, but no information on the frequency of increases in a routine clinical setting exists. The aim of this study was to assess the frequency of an increased ESR in dogs and to investigate its possible association with hematologic changes; (2) Methods: A total of 295 EDTA blood samples were randomly selected from the routine caseload of the Veterinary Teaching Hospital. Samples were grouped in controls and in pathologic groups based on the clinical presentation. A routine hemogram was performed, then the ESR was measured using the instrument MINI-PET; (3) Results: compared with controls, the ESR was significantly higher in all the pathologic groups, except for the hematological disorders group. The highest ESR was found in samples from dogs with chronic kidney disease or inflammation, followed by those from dogs with mild chronic disorders, severe/acute diseases, tumors and urinary disorders. The ESR negatively correlated with hematocrit and positively with neutrophil counts. (4) Conclusions: The ESR increases more frequently in dogs with clinically evident inflammation or CKD, but also in several other conditions, likely as a consequence of anemia and acute phase response.

2.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38473029

ABSTRACT

The Erythrocyte Sedimentation Rate (ESR) is a diagnostic estimator of systemic inflammation as a reflection of acute phase proteins circulating in the blood. The purpose of this manuscript is to evaluate the blood stability at room temperature (RT) and at 4 °C to avoid ESR diagnostic errors, as well as the accuracy of the VES-MATIC 5 analyzer. The ESR stability evaluation at RT for 24 h (4 h "T1", 6 h "T2", 8 h "T3", 10 h "T4", 24 h "T5") and at 4 °C (24 h, 36 h, 48 h) was carried out using 635 total samples, starting with T0 (2 h of venipuncture). For method comparison, 164 patients were analyzed using VES-MATIC 5 and then the Westergren reference method. The sample at RT is established by a significant gradual decrease in correlation R = 0.99 (T0 vs. T1), R = 0.97 (T0 vs. T2), R = 0.92 (T0 vs. T3), R = 0.87 (T0 vs. T4), and R = 0.40 (T0 vs. T5). The stability at 4 °C after 24 h, 36 h, and 48 h showed a regression of R = 0.99, R = 0.97, and R = 0.95, respectively. Therefore, ESR measurements on RT samples beyond 6 h after collection cannot be carried out, but the ESR can be measured until 36 h for samples stored at 4 °C. Moreover, the VES-MATIC 5 accuracy performance compared to the Westergren method (R = 0.96) is confirmed.

3.
Vet Med Int ; 2023: 9965095, 2023.
Article in English | MEDLINE | ID: mdl-38023429

ABSTRACT

The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR values are associated with various disorders, including infections, rheumatoid arthritis, oncologic diseases, and other inflammatory conditions. The ESR can also be influenced by some factors such as age and gender. In veterinary medicine, the ESR with the Westergren manual method was almost forgotten over the years due to blood consumption and long turn-around time. The instrument MINI-PET, using a modified Westergren method, does not require blood consumption or release waste product and recently has been applied in canine medicine. The aims of the study in the horse were as follows: to establish the appropriate time to read the ESR with the Westergren reference method; to compare the MINI-PET ESR results with the reference technique; to assess the ESR reference intervals with MINI-PET; and to establish the ESR stability from collection at different time points by MINI-PET. Using 150 horses, we established 60 minutes as the appropriate time for ESR reading with the Westergren method. Moreover, ESR results obtained in 8 minutes with MINI-PET showed a good correlation with the Westergren ESR. Reference intervals (RIs) with MINI-PET were established in mm/h for the healthy horses (geldings 18.6-100.1; stallions, 13.8-55.7; and mares 1-73.7) according to the American Society of Veterinary Clinical Pathology guidelines. In addition, the ESR stability from the blood collection time was evaluated in the MINI-PET on 15 horses: at room temperature, ESR is stable up to 8 hours and at 4°C up to 24 hours. In conclusion, MINI-PET represents a rapid and reliable tool for measuring ESR in horses, offering a valid option to replace the traditional manual technique.

4.
Acta Cir Bras ; 36(6): e360608, 2021.
Article in English | MEDLINE | ID: mdl-34231654

ABSTRACT

PURPOSE: To reduce false-negative rates (FNR) in sentinel lymph node biopsy (SLNB) of clinically positive (cN+) axilla in patients undergoing neoadjuvant chemotherapy (NAC). The removal of three or more lymph nodes with dual-tracer mapping including a radioisotope was used. However, in the Brazilian Unified Health System, the radioisotope tracer is not feasible in some hospitals. We conducted a cross-sectional study to evaluate the detection rate of sentinel lymph node (SLN) in patients who converted from cN+ to ycN0 after NAC using blue dye as a single-agent mapping tracer. METHODS: During the period of March 2018 to September 2019, 34 patients who underwent NAC with cN+ who converted to ycN0 were enrolled in the study. The SLNB was performed using blue dye as a single-agent mapping followed by axillary lymph node dissection (ALND). RESULTS: The detection rate of sentinel lymph node was of 85.3%, being SLNB not possible for five patients (14.7%), due to fibrosis. The mean number of removed SLN was 2.5. CONCLUSIONS: The use of blue dye as a single-agent mapping tracer demonstrated an acceptable detection rate of 85.3%. Although the FNR was possible to be determined, the small sample size might overestimate this rate. The removal of three or more lymph nodes with single-agent mapping tracer might be indicated for breast cancer patients who converted to ycN0 after NAC in the Brazilian health public services, in which radioisotope tracer is not suitable.


Subject(s)
Breast Neoplasms , Sentinel Lymph Node Biopsy , Axilla , Brazil , Breast Neoplasms/drug therapy , Breast Neoplasms/surgery , Cross-Sectional Studies , Female , Humans , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis , Neoadjuvant Therapy
5.
Acta cir. bras ; 36(6): e360608, 2021. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1278115

ABSTRACT

ABSTRACT Purpose To reduce false-negative rates (FNR) in sentinel lymph node biopsy (SLNB) of clinically positive (cN+) axilla in patients undergoing neoadjuvant chemotherapy (NAC). The removal of three or more lymph nodes with dual-tracer mapping including a radioisotope was used. However, in the Brazilian Unified Health System, the radioisotope tracer is not feasible in some hospitals. We conducted a cross-sectional study to evaluate the detection rate of sentinel lymph node (SLN) in patients who converted from cN+ to ycN0 after NAC using blue dye as a single-agent mapping tracer. Methods During the period of March 2018 to September 2019, 34 patients who underwent NAC with cN+ who converted to ycN0 were enrolled in the study. The SLNB was performed using blue dye as a single-agent mapping followed by axillary lymph node dissection (ALND). Results The detection rate of sentinel lymph node was of 85.3%, being SLNB not possible for five patients (14.7%), due to fibrosis. The mean number of removed SLN was 2.5. Conclusions The use of blue dye as a single-agent mapping tracer demonstrated an acceptable detection rate of 85.3%. Although the FNR was possible to be determined, the small sample size might overestimate this rate. The removal of three or more lymph nodes with single-agent mapping tracer might be indicated for breast cancer patients who converted to ycN0 after NAC in the Brazilian health public services, in which radioisotope tracer is not suitable.


Subject(s)
Humans , Female , Breast Neoplasms/surgery , Breast Neoplasms/drug therapy , Sentinel Lymph Node Biopsy , Axilla , Brazil , Cross-Sectional Studies , Neoadjuvant Therapy , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis
SELECTION OF CITATIONS
SEARCH DETAIL
...