Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
1.
Mayo Clin Proc ; 99(5): 754-765, 2024 May.
Article in English | MEDLINE | ID: mdl-38180394

ABSTRACT

OBJECTIVE: To compare outcomes after left atrial appendage occlusion (LAAO) via implanted device vs no LAAO in a matched cohort of patients with atrial fibrillation (AF). METHODS: This longitudinal retrospective cohort study was based on the national database covering hospital care for the entire French population. Adults (≥18 years of age) who had been hospitalized with AF (January 1, 2015, to January 1, 2020) who underwent LAAO were identified. Propensity score matching was used to control for potential confounders of the treatment-outcome relationship. The primary outcome was a composite of ischemic stroke, major bleeding, or all-cause death during follow-up. RESULTS: After propensity score matching, 1216 patients with AF who were treated with LAAO were matched with 1216 controls (patients AF who were not treated with LAAO). Mean follow-up was 14.5 months (median, 13 months; IQR, 7-21 months). Patients with LAAO had a lower risk of the composite outcome (HR, 0.48; 95% CI, 0.42 to 0.55). Total events (309 for LAAO vs 640 for controls) and event rates (23.3% vs 44.0%/year, respectively) were lower for LAAO, driven primarily by a decreased risk of all-cause death (HR, 0.39; 95% CI, 0.33 to 0.46; P<.0001), whereas ischemic stroke risk was higher (HR, 1.75; 95% CI, 1.17 to 2.64). Significant interactions were observed in subgroups with a history of ischemic stroke (P<.001) and of bleeding (P=.002). CONCLUSION: Among AF patients at high bleeding risk, our nationwide study highlights a high risk of clinical events during follow-up. LAAO appeared less effective than no LAAO in preventing stroke but more effective in preventing death. Left atrial appendage occlusion is particularly effective in patients with previous ischemic stroke or any episode of bleeding.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Fibrillation/surgery , Atrial Appendage/surgery , Male , Female , Aged , Retrospective Studies , Propensity Score , Longitudinal Studies , Middle Aged , Treatment Outcome , Septal Occluder Device , Ischemic Stroke/prevention & control , Ischemic Stroke/etiology , Ischemic Stroke/epidemiology , Aged, 80 and over , France/epidemiology
2.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38234123

ABSTRACT

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Subject(s)
Heart Failure , Quality of Life , Humans , Cohort Studies , Stroke Volume , Prospective Studies , Biological Specimen Banks , Ventricular Function, Left , Algorithms
3.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Article in English | MEDLINE | ID: mdl-37634520

ABSTRACT

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Male , Female , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Prospective Studies , Treatment Outcome , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Stroke Volume , Electrocardiography
4.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37558371

ABSTRACT

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Transposition of Great Vessels , Humans , Female , Young Adult , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Cohort Studies , Treatment Outcome , Retrospective Studies , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy
5.
Front Cardiovasc Med ; 10: 1148052, 2023.
Article in English | MEDLINE | ID: mdl-37025684

ABSTRACT

Background: Fat layers in obese patients can impair R-wave detection and diagnostic performance of a subcutaneous insertable cardiac monitor (ICM). We compared safety and ICM sensing quality between obese patients [body mass index (BMI) ≥ 30 kg/m2] and normal-weight controls (BMI <30 kg/m2) in terms of R-wave amplitude and time in noise mode (noise burden) detected by a long-sensing-vector ICM. Materials and methods: Patients from two multicentre, non-randomized clinical registries are included in the present analysis on January 31, 2022 (data freeze), if the follow-up period was at least 90 days after ICM insertion, including daily remote monitoring. The R-wave amplitudes and daily noise burden averaged intraindividually for days 61-90 and days 1-90, respectively, were compared between obese patients (n = 104) and unmatched (n = 268) and a nearest-neighbour propensity score (PS) matched (n = 69) normal-weight controls. Results: The average R-wave amplitude was significantly lower in obese (median 0.46 mV) than in normal-weight unmatched (0.70 mV, P < 0.0001) or PS-matched (0.60 mV, P = 0.003) patients. The median noise burden was 1.0% in obese patients, which was not significantly higher than in unmatched (0.7%; P = 0.056) or PS-matched (0.8%; P = 0.133) controls. The rate of adverse device effects during the first 90 days did not differ significantly between groups. Conclusion: Although increased BMI was associated with reduced signal amplitude, also in obese patients the median R-wave amplitude was >0.3 mV, a value which is generally accepted as the minimum level for adequate R-wave detection. The noise burden and adverse event rates did not differ significantly between obese and normal-weight patients.Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04075084 and NCT04198220.

6.
Heart Rhythm O2 ; 4(2): 97-102, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36873314

ABSTRACT

Background: Insertable cardiac monitors (ICMs) are increasingly used for cardiac rhythm diagnosis with expanding indications. Little has been reported about their use and efficacy. Objective: The study sought to evaluate the clinical utility of a novel ICM (Biotronik BIOMONITOR III) including the time to diagnosis in unselected patients with different ICM indications. Methods: Patients from 2 prospective clinical studies were included to determine the diagnostic yield of the ICM. The primary endpoint was time to clinical diagnosis per implant indication or to the first change in atrial fibrillation (AF) therapy. Results: A total of 632 patients were included with a mean follow-up of 233 ± 168 days. Of 384 patients with (pre)syncope, 34.2% had a diagnosis at 1 year. The most frequent therapy was permanent pacemaker implantation. Of 133 patients with cryptogenic stroke, 16.6% had an AF diagnosis at 1 year, resulting in oral anticoagulation. Of 49 patients with an indication for AF monitoring, 41.0% had a relevant change in AF therapy based on ICM data at 1 year. Of 66 patients with other indications, 35.4% received a rhythm diagnosis at 1 year. Moreover, 6.5% of the cohort had additional diagnoses: 26 of 384 patients with syncope, 8 of 133 patients with cryptogenic stroke, and 7 of 49 patients with AF monitoring. Conclusion: In a large unselected patient population with heterogeneous ICM indications, the primary endpoint of rhythm diagnosis was achieved in ∼1 in 4, and additional clinically relevant findings was achieved in 6.5% of patients at short-term follow-up.

7.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Article in English | MEDLINE | ID: mdl-36309156

ABSTRACT

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Tetralogy of Fallot , Male , Humans , Adult , Middle Aged , Female , Stroke Volume , Tetralogy of Fallot/complications , Tetralogy of Fallot/surgery , Follow-Up Studies , Ventricular Function, Right , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation
8.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Article in English | MEDLINE | ID: mdl-36266008

ABSTRACT

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Tetralogy of Fallot , Humans , Female , Male , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Tetralogy of Fallot/complications , Cohort Studies , Sex Characteristics , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Heart Defects, Congenital/complications
9.
J Am Heart Assoc ; 11(16): e025339, 2022 08 16.
Article in English | MEDLINE | ID: mdl-35929449

ABSTRACT

Background Leadless ventricular permanent pacemakers (leadless VVI or LPM) were designed to reduce lead-related complications of conventional VVI pacemakers (CPM). The aim of our study was to assess and compare real-life clinical outcomes within the first 30 days and during a midterm follow-up with the 2 techniques. Methods and Results This French longitudinal cohort study was based on the national hospitalization database. All adults (age ≥18 years) hospitalized in French hospitals from January 1, 2017 to September 1, 2020, who underwent a first LPM or CPM were included. The study included 40 828 patients with CPM and 1487 with LPM. After propensity score matching 1344 patients with CPM were matched 1:1 with patients treated with LPM. Patients with LPM had a lower rate of all-cause and cardiovascular death within the 30 days after implantation. During subsequent follow-up (mean: 8.6±10.5 months), risk of all-cause death in the unmatched population was significantly higher in the LPM group than in the CPM group, whereas risk of cardiovascular death and of endocarditis was not significantly different. After matching on all baseline characteristics including comorbidities (mean follow-up 6.2±8.7 months), all-cause death, cardiovascular death, and infective endocarditis were not statistically different in the 2 groups. Conclusions Patients treated with leadless VVI pacemakers had better clinical outcomes in the first month compared with the patients treated with conventional VVI pacing. During a midterm follow-up, risk of all-cause death, cardiovascular death, and endocarditis in patients treated with leadless VVI pacemaker was not statistically different after propensity score matching.


Subject(s)
Arrhythmias, Cardiac , Pacemaker, Artificial , Adolescent , Cardiac Pacing, Artificial/methods , Equipment Design , Heart Ventricles , Humans , Longitudinal Studies , Pacemaker, Artificial/adverse effects , Treatment Outcome
10.
Heart Rhythm O2 ; 3(2): 152-159, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35496450

ABSTRACT

Background: Insertable cardiac monitors (ICMs) require an invasive procedure and are used for purely diagnostic purposes. Therefore, simplicity of the insertion procedure, low complication rate, long-term patient acceptance, sensing quality, and reliable remote monitoring are of great importance. Objective: To evaluate a novel ICM (BIOMONITOR III) regarding all these aspects. Methods: BIOMONITOR III has a miniaturized profile, long sensing vector (≈70 mm), a fast insertion tool for pocket formation and ICM placement in 1 step, and daily automatic Home Monitoring (HM) function. We evaluated the insertion procedure, complication rate, patient acceptance, sensing quality, and HM performance in 653 patients with BIOMONITOR III inserted for any ICM indication within 2 ongoing studies involving 51 sites in 11 countries. Results: The median time from skin incision to wound closure was 4.0 minutes (interquartile range, 2.3-6.2 minutes). Median follow-up period was 274 days (interquartile range, 175-342 days). Serious adverse device-related events occurred in 6 patients (0.9%). No deep infections were reported in 334 patients without antibiotic prophylaxis. The wearing comfort was good or excellent in ≈95%. The mean R-wave amplitude (0.73 mV) and HM transmission rate (≈94% of days) were stable over 1.5 years. R-wave amplitudes were larger (mean 0.80 vs 0.62 mV, P < .001) and noise burden was lower (median 3.7 vs 14.5 minutes/day, P < .001) for ICM insertions parallel to the heart's long axis (54.2%) vs parasternal (41.3%). A gross visibility of P waves was 95.1%. Conclusion: The study demonstrated fast insertion times, low complication rate, high patient acceptance, and favorable long-term sensing and HM performance of the ICM.

11.
Heart ; 108(15): 1186-1193, 2022 07 13.
Article in English | MEDLINE | ID: mdl-35410895

ABSTRACT

BACKGROUND: Risk-benefit for cardiac resynchronisation therapy (CRT) defibrillator (CRT-D) over CRT pacemaker remains a matter of debate. We aimed to identify patients with a poor outcome within 1 year of CRT-D implantation, and to develop a CRT-D Futility score. METHODS: Based on an administrative hospital-discharge database, all consecutive patients treated with prophylactic CRT-D implantation in France (2010-2019) were included. A prediction model was derived and validated for 1-year all-cause death after CRT-D implantation (considered as futility) by using split-sample validation. RESULTS: Among 23 029 patients (mean age 68±10 years; 4873 (21.2%) women), 7016 deaths were recorded (yearly incidence rate 7.2%), of which 1604 (22.8%) occurred within 1 year of CRT-D implantation. In the derivation cohort (n=11 514), the final logistic regression model included-as main predictors of futility-older age, diabetes, mitral regurgitation, aortic stenosis, history of hospitalisation with heart failure, history of pulmonary oedema, atrial fibrillation, renal disease, liver disease, undernutrition and anaemia. Area under the curve for the CRT-D Futility score was 0.716 (95% CI: 0.698 to 0.734) in the derivation cohort and 0.692 (0.673 to 0.710) in the validation cohort. The Hosmer-Lemeshow test had a p-value of 0.57 suggesting accurate calibration. The CRT-D Futility score outperformed the Goldenberg and EAARN scores for identifying futility. Based on the CRT-D Futility score, 15.9% of these patients were categorised at high risk (predicted futility of 16.6%). CONCLUSIONS: The CRT-D Futility score, established from a large nationwide cohort of patients treated with CRT-D, may be a relevant tool for optimising healthcare decision-making.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Pacemaker, Artificial , Aged , Cardiac Resynchronization Therapy/adverse effects , Female , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/therapy , Humans , Male , Medical Futility , Middle Aged , Risk Factors , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 33(4): 731-737, 2022 04.
Article in English | MEDLINE | ID: mdl-35138039

ABSTRACT

INTRODUCTION: The aim of this study was to assess the safety and efficacy of the TightRail™ sheath for pacemaker/defibrillator transvenous lead extraction (TLE). METHODS: Multicenter observational study including patients who underwent a TLE with the TightRail™ sheath in five French university hospitals from September 2014 to January 2020. RESULTS: Two hundred and twenty-five patients (76% males, 71 ± 12 years) underwent a TLE procedure with the TightRail™. A total of 438 leads were extracted using the TightRail™, and the mean age of the extracted leads was 128 ± 85 months; of these, 344 (79%) were pacing leads and 94 (21%) were implantable cardioverter defibrillator leads. The overall clinical success of the extraction procedures was 93%. Overall, 410 of the 438 leads (95%) were extracted (complete or incomplete removal). After multilevel mixed-effects logistic regression model, we found that lead age (odds ratio [OR], 95% confidence interval [CI] for a 1 year increase: 1.11 [1.07-1.15], p < .001) and number of leads extracted (OR, 95% CI: 2.09 [1.50-2.96], p < .001) were the two independent factors associated with complete lead removal failure. Finally, there were 7 (3%) cases of major complications but no per-procedural death. CONCLUSION: This is the first large-scale survey assessing the efficacy and safety profile of the Tightrail™ mechanical sheath. The clinical success rate was 93%, and the lead removal failure was dependent on the age and number of leads. We show a satisfactory safety profile in this cohort of patients from primarily low-volume centers with older leads.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Device Removal/adverse effects , Female , Humans , Male , Retrospective Studies , Treatment Outcome
13.
Stroke ; 53(2): 497-504, 2022 02.
Article in English | MEDLINE | ID: mdl-34601900

ABSTRACT

BACKGROUND AND PURPOSE: Patients with hypertrophic cardiomyopathy (HCM) have high risk of ischemic stroke (IS), especially if atrial fibrillation (AF) is present. Improvements in risk stratification are needed to help identify those patients with HCM at higher risk of stroke, whether AF is present or not. METHODS: This French longitudinal cohort study from the database covering hospital care from 2010 to 2019 analyzed adults hospitalized with isolated HCM. A logistic regression model was used to construct a French HCM score, which was compared with the HCM Risk-CVA and CHA2DS2-VASc scores using c-indexes and calibration analysis. RESULTS: In 32 206 patients with isolated HCM, 12 498 (38.8%) had AF, and 2489 (7.7%) sustained an IS during follow-up. AF in patients with HCM was independently associated with a higher risk for death (hazard ratio, 1.129 [95% CI, 1.088-1.172]), cardiovascular death (hazard ratio, 1.254 [95% CI, 1.177-1.337]), IS (hazard ratio, 1.210 [95% CI, 1.111-1.317]), and other major cardiovascular events. Independent predictors of IS in HCM were older age, heart failure, AF, prior IS, smoking and poor nutrition (all P<0.05). For the HCM Risk-CVA score, CHA2DS2-VASc score and a French HCM score, all c-indexes were 0.65 to 0.70, with good calibration. Among patients with AF, the CHA2DS2-VASc score had marginal improvement over the HCM Risk-CVA score but was less predictive compared with the French HCM score (P=0.001). In patients without AF, both HCM Risk-CVA score and the French HCM score had significantly better prediction compared with CHA2DS2-VASc (both P<0.0001). Decision curve analysis demonstrated that the French HCM score had the best clinical usefulness of the 3 tested risk scores. CONCLUSIONS: Patients with HCM have a high prevalence of AF and a significant risk of IS, and the presence of AF in patients with HCM was independently associated with worse outcomes. A simple French HCM score shows good prediction of IS in patients with HCM and clinical usefulness, with good calibration.


Subject(s)
Atrial Fibrillation/complications , Cardiomyopathy, Hypertrophic/complications , Ischemic Stroke/complications , Adult , Age Factors , Aged , Aged, 80 and over , Atrial Fibrillation/epidemiology , Cardiomyopathy, Hypertrophic/epidemiology , Cohort Studies , Female , Follow-Up Studies , France/epidemiology , Heart Failure/complications , Humans , Ischemic Stroke/epidemiology , Longitudinal Studies , Male , Middle Aged , Nutritional Status , Predictive Value of Tests , Risk Assessment , Risk Factors , Smoking/adverse effects , Smoking/epidemiology , Treatment Outcome
14.
Europace ; 24(2): 285-295, 2022 02 02.
Article in English | MEDLINE | ID: mdl-34491328

ABSTRACT

AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.


Subject(s)
Cardiomyopathies , Tachycardia, Ventricular , Bundle-Branch Block/diagnosis , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Cardiomyopathies/complications , Cardiomyopathies/epidemiology , Cardiomyopathies/genetics , Electrocardiography , Female , Humans , Male , Prevalence , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/genetics
15.
Heart Rhythm ; 18(12): 2027-2032, 2021 12.
Article in English | MEDLINE | ID: mdl-34147701

ABSTRACT

BACKGROUND: Conduction abnormalities following transcatheter aortic valve replacement (TAVR) often may require permanent pacemaker implantation (PPM). OBJECTIVE: The purpose of this study was to evaluate outcomes associated with PPM after a TAVR procedure in a large, nationwide-level population. METHODS: Based on the administrative hospital discharge database, the incidence of all-cause death, cardiovascular death, and hospitalization for heart failure (HF) were retrospectively collected, based on the presence or absence of PPM, in the first 30 days following all TAVRs in France from 2010 to 2019. RESULTS: Among 520,662 patients hospitalized for aortic stenosis, 49,201 were treated with TAVR. A total of 29,422 patients had follow-up ≥6 months (median 1.7 years), 22% already had PPM at baseline, and 22% underwent PPM within the first 30 days post-TAVR. Adjusted hazard ratios for the combined risk of all-cause death and hospitalization for HF, during the whole follow-up, were higher in both patients with a previous PPM and in those implanted within 30 days (hazard ratio [95% confidence interval] 1.12 [1.07-1.17] and 1.11 [1.06-1.16], respectively). CONCLUSION: PPM at baseline and within 30 days post-TAVR are independently associated with higher mortality and HF hospitalization during follow-up.


Subject(s)
Aortic Valve Stenosis/surgery , Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Heart Valve Prosthesis/adverse effects , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Female , Follow-Up Studies , France/epidemiology , Humans , Incidence , Male , Patient Readmission , Postoperative Complications/etiology , Retrospective Studies , Risk Factors
16.
JACC Clin Electrophysiol ; 7(10): 1285-1293, 2021 10.
Article in English | MEDLINE | ID: mdl-33933408

ABSTRACT

OBJECTIVES: This study aimed to assess the impact of pulmonary valve replacement (PVR) on ventricular arrhythmias burden in a population of tetralogy of Fallot (TOF) patients with continuous cardiac monitoring by implantable cardioverter-defibrillators (ICDs). BACKGROUND: Sudden cardiac death is a major cause of death in TOF, and right ventricular overload is commonly considered to be a potential trigger for ventricular arrhythmias. METHODS: Data were analyzed from a nationwide French ongoing study (DAI-T4F) including all TOF patients with an ICD since 2000. Survival data with recurrent events were used to compare the burden of appropriate ICD therapies before and after PVR in patients who underwent PVR over the study period. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years, 70.1% male) were included from 40 centers. Over a median follow-up period of 6.8 (interquartile range: 2.5 to 11.4) years, 26 patients (15.8%) underwent PVR. Among those patients, 18 (69.2%) experienced at least 1 appropriate ICD therapy. When considering all ICD therapies delivered before (n = 62) and after (n = 16) PVR, the burden of appropriate ICD therapies was significantly lower after PVR (HR: 0.21; 95% confidence interval [CI]: 0.08 to 0.56; p = 0.002). Respective appropriate ICD therapies rates per 100 person-years were 44.0 (95% CI: 35.7 to 52.5) before and 13.2 (95% CI: 7.7 to 20.5) after PVR (p < 0.001). In the overall cohort, PVR before ICD implantation was also independently associated with a lower risk of appropriate ICD therapy in primary prevention patients (HR: 0.29 [95% CI: 0.10 to 0.89]; p = 0.031). CONCLUSIONS: In this cohort of high-risk TOF patients implanted with an ICD, the burden of appropriate ICD therapies was significantly reduced after PVR. While optimal indications and timing for PVR are debated, these findings suggest the importance of considering ventricular arrhythmias in the overall decision-making process. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Subject(s)
Cardiac Surgical Procedures , Defibrillators, Implantable , Pulmonary Valve , Tetralogy of Fallot , Adult , Arrhythmias, Cardiac/therapy , Female , Humans , Male , Middle Aged , Pulmonary Valve/surgery , Tetralogy of Fallot/surgery
17.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Article in English | MEDLINE | ID: mdl-32998542

ABSTRACT

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Subject(s)
Defibrillators, Implantable/trends , Tetralogy of Fallot/epidemiology , Tetralogy of Fallot/therapy , Adult , Female , Follow-Up Studies , Humans , Male , Registries
19.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Article in English | MEDLINE | ID: mdl-32627211

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Subject(s)
Defibrillators, Implantable/adverse effects , Electrodes, Implanted/adverse effects , Heart-Assist Devices , Aged , France , Humans , Male , Middle Aged , Prosthesis Failure
20.
Europace ; 22(8): 1224-1233, 2020 08 01.
Article in English | MEDLINE | ID: mdl-32594143

ABSTRACT

AIMS: Cardiac resynchronization therapy with (CRTD) or without (CRTP) defibrillator is recommended in selected patient with systolic chronic heart failure and wide QRS. There is no guideline firmly indicating choice between CRTP and CRTD in primary prevention, particularly in older patients. METHODS AND RESULTS: Based on the French administrative hospital-discharge database, information was collected from 2010 to 2017 for all patients implanted with CRTP or CRTD in primary prevention. Outcome analyses were undertaken in the total study population and in propensity-matched samples. During follow-up (913 days, SD 841, median 701, IQR 151-1493), 45 697 patients were analysed (CRTP 19 266 and CRTD 26 431). Incidence rate (%patient/year) of all-cause mortality was higher in CRTP patients (11.6%) than in CRTD patients (6.8%) [hazard ratio (HR) 1.70, 95% confidence interval (CI) 1.63-1.76, P < 0.001]. After propensity-matched analyses, mortality of patients over 75 years old with non-ischaemic cardiomyopathy (NICM) was not different with CRTP and CRTD (HR 0.93, 95% CI 0.80-1.09, P = 0.39). The CRTP patients under 75 years old with NICM had a higher mortality than CRTD patients (HR 1.22, 95% CI 1.03-1.45, P = 0.02). Mortality rate was also higher with CRTP than with CRTD irrespectively of age in patients with ischaemic cardiomyopathy (ICM) (<75 years old: HR 1.22, 95% CI 1.08-1.37, P = 0.01; ≥75 years old: HR 1.13, 95% CI 1.04-1.22, P = 0.003). CONCLUSION: In this real-life study, CRTD was associated with a significantly lower all-cause mortality than CRTP in patients with ICM and in patients with NICM under 75 years old. Patients over 75 years old with NICM did not have lower mortality with primary prevention CRTD implantation.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Myocardial Ischemia , Aged , Cardiac Resynchronization Therapy Devices , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Primary Prevention , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...