Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 83
Filter
1.
Insights Imaging ; 15(1): 131, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38816526

ABSTRACT

OBJECTIVE: To evaluate the diagnostic accuracy of supplemental 3D automated breast ultrasound (ABUS) in the diagnostic work-up of BI-RADS 0 recalls. We hypothesized that 3D ABUS may reduce the benign biopsy rate. MATERIALS AND METHODS: In this prospective multicenter diagnostic study, screening participants recalled after a BI-RADS 0 result underwent bilateral 3D ABUS supplemental to usual care: digital breast tomosynthesis (DBT) and targeted hand-held ultrasound (HHUS). Sensitivity, specificity, positive predictive value, and negative predictive value of 3D ABUS, and DBT plus HHUS, were calculated. New 3D ABUS findings and changes of management (biopsy or additional imaging) were recorded. RESULTS: A total of 501 women (median age 55 years, IQR [51-64]) with 525 BI-RADS 0 lesions were included between April 2018 and March 2020. Cancer was diagnosed in 45 patients. 3D ABUS sensitivity was 72.1% (95% CI [57.2-83.4%]), specificity 84.4% (95% CI [80.8-87.4%]), PPV 29.2% (95% CI [21.4-38.5%]), and NPV 97.1% 95.0-98.4%). Sensitivity of DBT plus HHUS was 100% (95% CI [90.2-100%]), specificity 71.4% (95% CI [67.2-75.2%]), PPV 23.8% (95% CI [18.1-30.5%]) and NPV 100% (95% CI [98.7-100%]). Twelve out of 43 (27.9%) malignancies in BI-RADS 0 lesions were missed on 3D ABUS, despite being detected on DBT and/or HHUS. Supplemental 3D ABUS resulted in the detection of 57 new lesions and six extra biopsy procedures, all were benign. CONCLUSION: 3D ABUS in the diagnostic work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with HHUS and/or DBT and should not be used to omit biopsy. Supplemental 3D ABUS increases the benign biopsy rate. TRIAL REGISTRATION: Dutch Trial Register, available via https://www.onderzoekmetmensen.nl/en/trial/29659 CRITICAL RELEVANCE STATEMENT: Supplemental 3D automated breast ultrasound in the work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with other methods and should not be used to omit biopsy; ABUS findings did increase benign biopsy rate. KEY POINTS: Automated breast ultrasound (ABUS) may miss over 25% of cancers detectable by alternative methods. Don't rely solely on 3D ABUS to assess indication for biopsy. New findings with supplemental 3D ABUS increase the benign biopsy rate.

2.
Eur J Radiol ; 175: 111442, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38583349

ABSTRACT

OBJECTIVES: Background parenchymal enhancement (BPE) on dynamic contrast-enhanced MRI (DCE-MRI) as rated by radiologists is subject to inter- and intrareader variability. We aim to automate BPE category from DCE-MRI. METHODS: This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial. 4553 women with extremely dense breasts who received supplemental breast MRI screening in eight hospitals were included. Minimal, mild, moderate and marked BPE rated by radiologists were used as reference. Fifteen quantitative MRI features of the fibroglandular tissue were extracted to predict BPE using Random Forest, Naïve Bayes, and KNN classifiers. Majority voting was used to combine the predictions. Internal-external validation was used for training and validation. The inverse-variance weighted mean accuracy was used to express mean performance across the eight hospitals. Cox regression was used to verify non inferiority of the association between automated rating and breast cancer occurrence compared to the association for manual rating. RESULTS: The accuracy of majority voting ranged between 0.56 and 0.84 across the eight hospitals. The weighted mean prediction accuracy for the four BPE categories was 0.76. The hazard ratio (HR) of BPE for breast cancer occurrence was comparable between automated rating and manual rating (HR = 2.12 versus HR = 1.97, P = 0.65 for mild/moderate/marked BPE relative to minimal BPE). CONCLUSION: It is feasible to rate BPE automatically in DCE-MRI of women with extremely dense breasts without compromising the underlying association between BPE and breast cancer occurrence. The accuracy for minimal BPE is superior to that for other BPE categories.


Subject(s)
Breast Density , Breast Neoplasms , Contrast Media , Magnetic Resonance Imaging , Humans , Female , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Middle Aged , Reproducibility of Results , Image Enhancement/methods , Early Detection of Cancer/methods , Aged , Breast/diagnostic imaging , Image Interpretation, Computer-Assisted/methods
3.
Eur Radiol ; 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38639912

ABSTRACT

OBJECTIVES: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion. METHODS: We calculated the re-attendance rates of the second and third MRI screening rounds of the DENSE trial. Moreover, we calculated age-adjusted odds ratios (ORs) to study the association between characteristics and re-attendance. Women who discontinued MRI screening were asked to provide one or more reasons for this. RESULTS: The re-attendance rates were 81.3% (3458/4252) and 85.2% (2693/3160) in the second and third MRI screening round, respectively. A high age (> 65 years), a very low BMI, lower education, not being employed, smoking, and no alcohol consumption were correlated with lower re-attendance rates. Moderate or high levels of pain, discomfort, or anxiety experienced during the previous MRI screening round were correlated with lower re-attendance rates. Finally, a plurality of women mentioned an examination-related inconvenience as a reason to discontinue screening (39.1% and 34.8% in the second and third screening round, respectively). CONCLUSIONS: The willingness of women with dense breasts to re-attend an ongoing MRI screening study is high. However, emphasis should be placed on improving the MRI experience to increase the re-attendance rate if widespread supplemental MRI screening is implemented. CLINICAL RELEVANCE STATEMENT: For many women, MRI is an acceptable screening method, as re-attendance rates were high - even for screening in a clinical trial setting. To further enhance the (re-)attendance rate, one possible approach could be improving the overall MRI experience. KEY POINTS: • The willingness to re-attend in an ongoing MRI screening study is high. • Pain, discomfort, and anxiety in the previous MRI screening round were related to lower re-attendance rates. • Emphasis should be placed on improving MRI experience to increase the re-attendance rate in supplemental MRI screening.

4.
Eur Radiol ; 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38488968

ABSTRACT

Women with a personal history of breast cancer (PHBC) are at an increased risk of either a local recurrence or a new primary breast cancer. Thus, surveillance is essential for the detection of recurrent disease at the earliest possible stage, allowing for prompt treatment, and potentially improving overall survival. Nowadays, mammography follow-up is the only surveillance imaging technique recommended by international guidelines. Nevertheless, sensitivity of mammography is lower after breast cancer treatment, particularly during the first 5 years, due to increased density or post-treatment changes. Contrast-enhanced breast imaging techniques, such as MRI or contrast-enhanced mammography (CEM), are very sensitive to detect malignant enhancement, especially in dense breasts. This Special Report will provide arguments in favor of and against breast cancer follow-up with MRI or CEM, in a debate style between experts in Breast Imaging. Finally, the scientific points of pros and cons arguments will be summarized to help objectively decide the best follow-up strategy for women with a personal history of breast cancer. CLINICAL RELEVANCE STATEMENT: A personalized approach to follow-up imaging after conservative breast cancer treatment could optimize patient outcomes, using mammography as a baseline for most patients, and MRI or CEM selectively in patients with higher risks for a recurrence. KEY POINTS: • Women with a personal history of breast cancer are at an increased risk of either a local recurrence or a new primary breast cancer. • Breast cancer survivors may benefit from additional imaging with MRI/CEM, in case of increased risk of a second breast cancer, with dense breasts or a cancer diagnosis before age 50 years. • As survival after local recurrence seems to depend on the initial stage at diagnosis, imaging should be more focused on detecting tumors in the earliest stages.

5.
Eur Radiol ; 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38227202

ABSTRACT

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.

6.
Eur J Cancer ; 198: 113500, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38199146

ABSTRACT

INTRODUCTION: Quality care in breast cancer is higher if patients are treated in a Breast Center with a dedicated and specialized multidisciplinary team. Quality control is an essential activity to ensure quality care, which has to be based on the monitoring of specific quality indicators. Eusoma has proceeded with the up-dating of the 2017 Quality indicators for non-metastatic breast cancer based on the new diagnostic, locoregional and systemic treatment modalities. METHODS: To proceed with the updating, EUSOMA setup a multidisciplinary working group of BC experts and patients' representatives. It is a comprehensive set of QIs for early breast cancer care, which are classified as mandatory, recommended, or observational. For the first time patient reported outcomes (PROMs) have been included. As used in the 2017 EUSOMA QIs, evidence levels were based on the short version of the US Agency for Healthcare Research and Quality. RESULTS: This is a set of quality indicators representative for the different steps of the patient pathway in non-metastatic setting, which allow Breast Centres to monitor their performance with referring standards, i.e minimum standard and target. CONCLUSIONS: Monitoring these Quality Indicators, within the Eusoma datacentre will allow to have a state of the art picture at European Breast Centres level and the development of challenging research projects.


Subject(s)
Breast Neoplasms , Quality Indicators, Health Care , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/therapy , Quality of Health Care
7.
Eur Radiol ; 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38008743

ABSTRACT

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

8.
Cancer Epidemiol ; 87: 102481, 2023 12.
Article in English | MEDLINE | ID: mdl-37897970

ABSTRACT

BACKGROUND: Comparing the impact of the COVID-19 pandemic on the incidence of newly diagnosed breast tumors and their tumor stage between the Netherlands and Norway will help us understand the effect of differences in governmental and social reactions towards the pandemic. METHODS: Women newly diagnosed with breast cancer in 2017-2021 were selected from the Netherlands Cancer Registry and the Cancer Registry of Norway. The crude breast cancer incidence rate (tumors per 100,000 women) during the first (March-September 2020), second (October 2020-April 2021), and Delta COVID-19 wave (May-December 2021) was compared with the incidence rate in the corresponding periods in 2017, 2018, and 2019. Incidence rates were stratified by age group, method of detection, and clinical tumor stage. RESULTS: During the first wave breast cancer incidence declined to a larger extent in the Netherlands than in Norway (27.7% vs. 17.2% decrease, respectively). In both countries, incidence decreased in women eligible for screening. In the Netherlands, incidence also decreased in women not eligible for screening. During the second wave an increase in the incidence of stage IV tumors in women aged 50-69 years was seen in the Netherlands. During the Delta wave an increase in overall incidence and incidence of stage I tumors was seen in Norway. CONCLUSION: Alterations in breast cancer incidence and tumor stage seem related to a combined effect of the suspension of the screening program, health care avoidance due to the severity of the pandemic, and other unknown factors.


Subject(s)
Breast Neoplasms , COVID-19 , Female , Humans , Breast Neoplasms/pathology , Incidence , Pandemics , Netherlands/epidemiology , Neoplasm Staging , Mass Screening/methods , COVID-19/epidemiology , COVID-19/pathology , Norway/epidemiology
9.
Radiology ; 308(2): e222841, 2023 08.
Article in English | MEDLINE | ID: mdl-37552061

ABSTRACT

Background Automated identification of quantitative breast parenchymal enhancement features on dynamic contrast-enhanced (DCE) MRI scans could provide added value in assessment of breast cancer risk in women with extremely dense breasts. Purpose To automatically identify quantitative properties of the breast parenchyma on baseline DCE MRI scans and assess their association with breast cancer occurrence in women with extremely dense breasts. Materials and Methods This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial. MRI was performed in eight hospitals between December 2011 and January 2016. After segmentation of fibroglandular tissue, quantitative features (including volumetric density, volumetric morphology, and enhancement characteristics) of the parenchyma were extracted from baseline MRI scans. Principal component analysis was used to identify parenchymal measures with the greatest variance. Multivariable Cox proportional hazards regression was applied to assess the association between breast cancer occurrence and quantitative parenchymal features, followed by stratification of significant features into tertiles. Results A total of 4553 women (mean age, 55.7 years ± 6 [SD]) with extremely dense breasts were included; of these women, 122 (3%) were diagnosed with breast cancer. Five principal components representing 96% of the variance were identified, and the component explaining the greatest independent variance (42%) consisted of MRI features relating to volume of enhancing parenchyma. Multivariable analysis showed that volume of enhancing parenchyma was associated with breast cancer occurrence (hazard ratio [HR], 1.09; 95% CI: 1.01, 1.18; P = .02). Additionally, women in the high tertile of volume of enhancing parenchyma showed a breast cancer occurrence twice that of women in the low tertile (HR, 2.09; 95% CI: 1.25, 3.61; P = .005). Conclusion In women with extremely dense breasts, a high volume of enhancing parenchyma on baseline DCE MRI scans was associated with increased occurrence of breast cancer as compared with a low volume of enhancing parenchyma. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Grimm in this issue.


Subject(s)
Breast Neoplasms , Female , Humans , Middle Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Breast Density , Mammography/methods , Breast/diagnostic imaging , Magnetic Resonance Imaging/methods
10.
Eur Radiol ; 33(11): 8103-8111, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37481690

ABSTRACT

OBJECTIVES: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS: An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS: In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION: QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT: Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS: The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.


Subject(s)
Breast Neoplasms , Radiologists , Humans , Female , Mammography/methods , Breast , Surveys and Questionnaires , Europe , Breast Neoplasms/diagnostic imaging , Mass Screening
11.
Insights Imaging ; 14(1): 126, 2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37466753

ABSTRACT

Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.

12.
Breast Cancer Res Treat ; 201(1): 67-75, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37322358

ABSTRACT

PURPOSE: In breast conserving surgery, accurate lesion localization is essential for obtaining adequate surgical margins. Preoperative wire localization (WL) and radioactive seed localization (RSL) are widely accepted methods to guide surgical excision of nonpalpable breast lesions but are limited by logistical challenges, migration issues, and legislative complexities. Radiofrequency identification (RFID) technology may offer a viable alternative. The purpose of this study was to evaluate the feasibility, clinical acceptability, and safety of RFID surgical guidance for localization of nonpalpable breast cancer. METHODS: In a prospective multicentre cohort study, the first 100 RFID localization procedures were included. The primary outcome was the percentage of clear resection margins and re-excision rate. Secondary outcomes included procedure details, user experience, learningcurve, and adverse events. RESULTS: Between April 2019 and May 2021, 100 women underwent RFID guided breast conserving surgery. Clear resection margins were obtained in 89 out of 96 included patients (92.7%), re-excision was indicated in three patients (3.1%). Radiologists reported difficulties with the placement of the RFID tag, partially related to the relatively large needle-applicator (12-gauge). This led to the premature termination of the study in the hospital using RSL as regular care. The radiologist experience was improved after a manufacturer modification of the needle-applicator. Surgical localization involved a low learning curve. Adverse events (n = 33) included dislocation of the marker during insertion (8%) and hematomas (9%). The majority of adverse events (85%) occurred using the first-generation needle-applicator. CONCLUSION: RFID technology is a potential alternative for non-radioactive and non-wire localization of nonpalpable breast lesions.


Subject(s)
Breast Neoplasms , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Prospective Studies , Margins of Excision , Cohort Studies , Feasibility Studies , Mastectomy, Segmental/methods
13.
J Am Coll Radiol ; 20(7): 671-684, 2023 07.
Article in English | MEDLINE | ID: mdl-37127220

ABSTRACT

PURPOSE: The aim of this study was to determine variability in visually assessed mammographic breast density categorization among radiologists practicing in Indonesia, the Netherlands, South Africa, and the United States. METHODS: Two hundred consecutive 2-D full-field digital screening mammograms obtained from September to December 2017 were selected and retrospectively reviewed from four global locations, for a total of 800 mammograms. Three breast radiologists in each location (team) provided consensus density assessments of all 800 mammograms using BI-RADS® density categorization. Interreader agreement was compared using Gwet's AC2 with quadratic weighting across all four density categories and Gwet's AC1 for binary comparison of combined not dense versus dense categories. Variability of distribution among teams was calculated using the Stuart-Maxwell test of marginal homogeneity across all four categories and using the McNemar test for not dense versus dense categories. To compare readers from a particular country on their own 200 mammograms versus the other three teams, density distribution was calculated using conditional logistic regression. RESULTS: For all 800 mammograms, interreader weighted agreement for distribution among four density categories was 0.86 (Gwet's AC2 with quadratic weighting; 95% confidence interval, 0.85-0.88), and for not dense versus dense categories, it was 0.66 (Gwet's AC1; 95% confidence interval, 0.63-0.70). Density distribution across four density categories was significantly different when teams were compared with one another and one team versus the other three teams combined (P < .001). Overall, all readers placed the largest number of mammograms in the scattered and heterogeneous categories. CONCLUSIONS: Although reader teams from four different global locations had almost perfect interreader agreement in BI-RADS density categorization, variability in density distribution across four categories remained statistically significant.


Subject(s)
Breast Density , Breast Neoplasms , Humans , Female , Observer Variation , Retrospective Studies , Mammography , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging
14.
Breast ; 69: 431-440, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37169601

ABSTRACT

BACKGROUND: In Dutch breast cancer screening, solitary, new or growing well-circumscribed masses should be recalled for further assessment. This results in cancers detected but also in false positive recalls, especially at initial screening. The aim of this study was to determine characteristics of well-circumscribed masses at mammography and identify potential methods to improve the recall strategy. METHODS: A systematic literature search was performed using PubMed. In addition, follow-up data were retrieved on all 8860 recalled women in a Dutch screening region from 2014 to 2019. RESULTS: Based on 15 articles identified in the literature search, we found that probably benign well-circumscribed masses that were kept under surveillance had a positive predictive value (PPV) of 0-2%. New or enlarging solitary well-circumscribed masses had a PPV of 10-12%. In general the detected carcinomas had a favorable prognosis. In our exploration of screening practice, 25% of recalls (2133/8860) were triggered by a well-circumscribed mass. Those recalls had a PPV of 2.0% for initial and 10.6% for subsequent screening. Most detected carcinomas had a favorable prognosis as well. CONCLUSION: To recognize malignancies presenting as well-circumscribed masses, identifying solitary, new or growing lesions is key. This information is missing at initial screening since prior examinations are not available, leading to a low PPV. Access to prior clinical examinations may therefore improve this PPV. In addition, given the generally favorable prognosis of screen-detected malignant well-circumscribed masses, one may opt to recall these lesions at subsequent screening, if grown, rather than at initial screening.


Subject(s)
Breast Neoplasms , Carcinoma , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Mass Screening , Mammography/methods , Predictive Value of Tests
15.
Radiology ; 307(4): e221922, 2023 05.
Article in English | MEDLINE | ID: mdl-36975820

ABSTRACT

Background Several single-center studies found that high contralateral parenchymal enhancement (CPE) at breast MRI was associated with improved long-term survival in patients with estrogen receptor (ER)-positive and human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Due to varying sample sizes, population characteristics, and follow-up times, consensus of the association is currently lacking. Purpose To confirm whether CPE is associated with long-term survival in a large multicenter retrospective cohort, and to investigate if CPE is associated with endocrine therapy effectiveness. Materials and Methods This multicenter observational cohort included women with unilateral ER-positive HER2-negative breast cancer (tumor size ≤50 mm and ≤three positive lymph nodes) who underwent MRI from January 2005 to December 2010. Overall survival (OS), recurrence-free survival (RFS), and distant RFS (DRFS) were assessed. Kaplan-Meier analysis was performed to investigate differences in absolute risk after 10 years, stratified according to CPE tertile. Multivariable Cox proportional hazards regression analysis was performed to investigate whether CPE was associated with prognosis and endocrine therapy effectiveness. Results Overall, 1432 women (median age, 54 years [IQR, 47-63 years]) were included from 10 centers. Differences in absolute OS after 10 years were stratified according to CPE tertile as follows: 88.5% (95% CI: 88.1, 89.1) in tertile 1, 85.8% (95% CI: 85.2, 86.3) in tertile 2, and 85.9% (95% CI: 85.4, 86.4) in tertile 3. CPE was independently associated with OS, with a hazard ratio (HR) of 1.17 (95% CI: 1.0, 1.36; P = .047), but was not associated with RFS (HR, 1.11; P = .16) or DRFS (HR, 1.11; P = .19). The effect of endocrine therapy on survival could not be accurately assessed; therefore, the association between endocrine therapy efficacy and CPE could not reliably be estimated. Conclusion High contralateral parenchymal enhancement was associated with a marginally decreased overall survival in patients with estrogen receptor-positive and human epidermal growth factor receptor 2-negative breast cancer, but was not associated with recurrence-free survival (RFS) or distant RFS. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Subject(s)
Breast Neoplasms , Triple Negative Breast Neoplasms , Humans , Female , Middle Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/metabolism , Receptors, Estrogen , Retrospective Studies , Triple Negative Breast Neoplasms/pathology , Breast/diagnostic imaging , Breast/metabolism , Prognosis , Receptor, ErbB-2/metabolism , Magnetic Resonance Imaging/methods , Disease-Free Survival , Neoplasm Recurrence, Local/pathology
16.
Invest Radiol ; 58(4): 293-298, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36256783

ABSTRACT

OBJECTIVES: Computer-aided triaging (CAT) and computer-aided diagnosis (CAD) of screening breast magnetic resonance imaging have shown potential to reduce the workload of radiologists in the context of dismissing normal breast scans and dismissing benign disease in women with extremely dense breasts. The aim of this study was to validate the potential of integrating CAT and CAD to reduce workload and workup on benign lesions in the second screening round of the DENSE trial, without missing cancer. METHODS: We included 2901 breast magnetic resonance imaging scans, obtained from 8 hospitals in the Netherlands. Computer-aided triaging and CAD were previously developed on data from the first screening round. Computer-aided triaging dismissed examinations without lesions. Magnetic resonance imaging examinations triaged to radiological reading were counted and subsequently processed by CAD. The number of benign lesions correctly classified by CAD was recorded. The false-positive fraction of the CAD was compared with that of unassisted radiological reading in the second screening round. Receiver operating characteristics (ROC) analysis was performed and the generalizability of CAT and CAD was assessed by comparing results from first and second screening rounds. RESULTS: Computer-aided triaging dismissed 950 of 2901 (32.7%) examinations with 49 lesions in total; none were malignant. Subsequent CAD classified 132 of 285 (46.3%) lesions as benign without misclassifying any malignant lesion. Together, CAT and CAD yielded significantly fewer false-positive lesions, 53 of 109 (48.6%) and 89 of 109 (78.9%), respectively ( P = 0.001), than radiological reading alone. Computer-aided triaging had a smaller area under the ROC curve in the second screening round compared with the first, 0.83 versus 0.76 ( P = 0.001), but this did not affect the negative predictive value at the 100% sensitivity operating threshold. Computer-aided diagnosis was not associated with significant differences in area under the ROC curve (0.857 vs 0.753, P = 0.08). At the operating thresholds, the specificities of CAT (39.7% vs 41.0%, P = 0.70) and CAD (41.0% vs 38.2%, P = 0.62) were successfully reproduced in the second round. CONCLUSION: The combined application of CAT and CAD showed potential to reduce workload of radiologists and to reduce number of biopsies on benign lesions. Computer-aided triaging (CAT) correctly dismissed 950 of 2901 (32.7%) examinations with 49 lesions in total; none were malignant. Subsequent computer-aided diagnosis (CAD) classified 132 of 285 (46.3%) lesions as benign without misclassifying any malignant lesion. Together, CAT and CAD yielded significantly fewer false-positive lesions, 53 of 109 (48.6%) and 89 of 109 (78.9%), respectively ( P = 0.001), than radiological reading alone.


Subject(s)
Deep Learning , Neoplasms , Female , Animals , Sensitivity and Specificity , Diagnosis, Computer-Assisted , Magnetic Resonance Imaging/methods , Mammography/methods
17.
Lancet Oncol ; 23(9): 1201-1210, 2022 09.
Article in English | MEDLINE | ID: mdl-35952707

ABSTRACT

BACKGROUND: Primary chemotherapy in breast cancer poses a dilemma with regard to adjuvant locoregional radiotherapy, as guidelines for locoregional radiotherapy were originally based on pathology results of primary surgery. We aimed to evaluate the oncological safety of de-escalated locoregional radiotherapy in patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to a predefined, consensus-based study guideline. METHODS: In this prospective registry study (RAPCHEM, BOOG 2010-03), patients referred to one of 17 participating radiation oncology centres in the Netherlands between Jan 1, 2011, and Jan 1, 2015, with cT1-2N1 breast cancer (one to three suspicious nodes on imaging before primary chemotherapy, of which at least one had been pathologically confirmed), and who were treated with primary chemotherapy and surgery of the breast and axilla were included in the study. The study guideline comprised three risk groups for locoregional recurrence, with corresponding locoregional radiotherapy recommendations: no chest wall radiotherapy and no regional radiotherapy in the low-risk group, only local radiotherapy in the intermediate-risk group, and locoregional radiotherapy in the high-risk group. Radiotherapy consisted of a biologically equivalent dose of 25 fractions of 2 Gy, with or without a boost. During the study period, the generally applied radiotherapy technique in the Netherlands was forward-planned or inverse-planned intensity modulated radiotherapy. 5-year follow-up was assessed, taking into account adherence to the study guideline, with locoregional recurrence rate as primary endpoint. We hypothesised that 5-year locoregional recurrence rate would be less than 4% (upper-limit 95% CI 7·8%). This study was registered at ClinicalTrials.gov, NCT01279304, and is completed. FINDINGS: 838 patients were eligible for 5-year follow-up analyses: 291 in the low-risk group, 370 in the intermediate-risk group, and 177 in the high-risk group. The 5-year locoregional recurrence rate in all patients was 2·2% (95% CI 1·4-3·4). The 5-year locoregional recurrence rate was 2·1% (0·9-4·3) in the low-risk group, 2·2% (1·0-4·1) in the intermediate-risk group, and 2·3% (0·8-5·5) in the high-risk group. If the study guideline was followed, the locoregional recurrence rate was 2·3% (0·8-5·3) for the low-risk group, 1·0% (0·2-3·4) for the intermediate-risk group, and 1·4% (0·3-4·5) for the high-risk group. INTERPRETATION: In this study, the 5-year locoregional recurrence rate was less than 4%, which supports our hypothesis that it is oncologically safe to de-escalate locoregional radiotherapy based on locoregional recurrence risk, in selected patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to this predefined, consensus-based study guideline. FUNDING: Dutch Cancer Society. TRANSLATION: For the Dutch translation of the abstract see Supplementary Materials section.


Subject(s)
Breast Neoplasms , Radiation Oncology , Breast Neoplasms/drug therapy , Breast Neoplasms/radiotherapy , Female , Follow-Up Studies , Humans , Mastectomy , Neoplasm Recurrence, Local/pathology , Radiotherapy, Adjuvant , Registries
18.
Eur Radiol ; 32(11): 7463-7469, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35482123

ABSTRACT

The magnitude of the tradeoff between recall rate (RR) and cancer detection rate (CDR) in breast-cancer screening is not clear, and it is expected to depend on target population and screening program characteristics. Multi-reader multi-case research studies, which may be used to estimate this tradeoff, rely on enriched datasets with artificially high prevalence rates, which may bias the results. Furthermore, readers participating in research studies are subject to "laboratory" effects, which can alter their performance relative to actual practice. The Recall and detection Of breast Cancer in Screening (ROCS) trial uses a novel data acquisition system that minimizes these limitations while obtaining an estimate of the RR-CDR curve during actual practice in the Dutch National Breast Cancer Screening Program. ROCS involves collection of at least 40,000 probability-of-malignancy ratings from at least 20 radiologists during interpretation of approximately 2,000 digital mammography screening cases each. With the use of custom-built software on a tablet, and a webcam, this data was obtained in the usual reading environment with minimal workflow disruption and without electronic access to the review workstation software. Comparison of the results to short- and medium-term follow-up allows for estimation of the RR-CDR and receiver operating characteristics curves, respectively. The anticipated result of the study is that performance-based evidence from practice will be available to determine the optimal operating point for breast-cancer screening. In addition, this data will be useful as a benchmark when evaluating the impact of potential new screening technologies, such as digital breast tomosynthesis or artificial intelligence. KEY POINTS: • The ROCS trial aims to estimate the recall rate-cancer detection rate curve during actual screening practice in the Dutch National Breast Cancer Screening Program. • The study design is aimed at avoiding the influence of the "laboratory effect" in usual observer performance studies. • The use of a tablet and a webcam allows for the acquisition of probability of malignancy ratings without access to the review workstation software.


Subject(s)
Breast Neoplasms , Early Detection of Cancer , Female , Humans , Artificial Intelligence , Breast Neoplasms/pathology , Early Detection of Cancer/methods , Mammography/methods , Mass Screening/methods
19.
BMC Cancer ; 22(1): 305, 2022 Mar 22.
Article in English | MEDLINE | ID: mdl-35317766

ABSTRACT

BACKGROUND: Breast cancer screening and improving imaging techniques have led to an increase in the detection rate of early, nonpalpable breast cancers. For early breast cancer, breast conserving surgery is an effective and safe treatment. Accurate intraoperative lesion localization during breast conserving surgery is essential for adequate surgical margins while sparing surrounding healthy tissue to achieve optimal cosmesis. Preoperative wire localization and radioactive seed localization are accepted standard methods to guide surgical excision of nonpalpable breast lesions. However, these techniques present significant limitations. Radiofrequency identification (RFID) technology offers a new, nonradioactive method for localizing nonpalpable breast lesions in patients undergoing breast conserving surgery. This study aims to evaluate the feasibility of RFID surgical guidance for nonpalpable breast lesions. METHODS: This multicenter prospective cohort study was approved by the Institutional Review Board of the University Medical Center Utrecht. Written informed consent is obtained from all participants. Women with nonpalpable, histologically proven in situ or invasive breast cancer, who can undergo breast conserving surgery with RFID localization are considered eligible for participation. An RFID tag is placed under ultrasound guidance, up to 30 days preoperatively. The surgeon localizes the RFID tag with a radiofrequency reader that provides audible and visual real-time surgical guidance. The primary study outcome is the percentage of irradical excisions and reexcision rate, which will be compared to standards of the National Breast Cancer Organisation Netherlands (NABON)(≤ 15% irradical excisions of invasive carcinomas). Secondary outcomes include user acceptability/experiences, learning curve, duration and ease of the placement- and surgical procedure and adverse events. DISCUSSION: This study evaluates the feasibility of RFID surgical guidance for nonpalpable breast lesions. Results may have implications for the future localization techniques in women with nonpalpable breast cancer undergoing breast conserving surgery. TRIAL REGISTRATION: Netherlands National Trial Register, NL8019 , registered on September 12th 2019.


Subject(s)
Breast Neoplasms/surgery , Mastectomy, Segmental/methods , Radio Frequency Identification Device , Adolescent , Adult , Breast Neoplasms/diagnosis , Feasibility Studies , Female , Humans , Margins of Excision , Prospective Studies , Young Adult
20.
Eur Radiol ; 32(6): 4036-4045, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35258677

ABSTRACT

Breast density is an independent risk factor for the development of breast cancer and also decreases the sensitivity of mammography for screening. Consequently, women with extremely dense breasts face an increased risk of late diagnosis of breast cancer. These women are, therefore, underserved with current mammographic screening programs. The results of recent studies reporting on contrast-enhanced breast MRI as a screening method in women with extremely dense breasts provide compelling evidence that this approach can enable an important reduction in breast cancer mortality for these women and is cost-effective. Because there is now a valid option to improve breast cancer screening, the European Society of Breast Imaging (EUSOBI) recommends that women should be informed about their breast density. EUSOBI thus calls on all providers of mammography screening to share density information with the women being screened. In light of the available evidence, in women aged 50 to 70 years with extremely dense breasts, the EUSOBI now recommends offering screening breast MRI every 2 to 4 years. The EUSOBI acknowledges that it may currently not be possible to offer breast MRI immediately and everywhere and underscores that quality assurance procedures need to be established, but urges radiological societies and policymakers to act on this now. Since the wishes and values of individual women differ, in screening the principles of shared decision-making should be embraced. In particular, women should be counselled on the benefits and risks of mammography and MRI-based screening, so that they are capable of making an informed choice about their preferred screening method. KEY POINTS: • The recommendations in Figure 1 summarize the key points of the manuscript.


Subject(s)
Breast Density , Breast Neoplasms , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Female , Humans , Mammography/methods , Mass Screening/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...