ABSTRACT

Purpose: To document the effect of the temporarily implanted nitinol device (iTind; Medi-Tate Ltd, Israel) on sexual function from a multicenter, randomized, single-blinded, sham-controlled trial. Materials and Methods: Men were randomized 2:1 between iTind and sham procedure arms. The iTind was placed for 5-7 days and an 18F Foley catheter was inserted and removed for the iTind and sham group, respectively. Patients were assessed at baseline, 3, and 12 months postoperatively using the Sexual Health Inventory for Men (SHIM) and International Index of Erectile Function (IIEF). Unblinding occurred at 3 months. Results: We studied 185 men with a mean age of 61.1 ± 6.5 years. There was no difference in SHIM or total IIEF between iTind and sham at 3 months or in the iTind arm at 12 months compared with baseline. Men in the iTind arm without erectile dysfunction at baseline showed an improvement in total IIEF score of +6.07 ± 21.17 points (p = 0.034) at 12 months, in addition to an improvement in ejaculatory function. SHIM scores remained unchanged in all groups, regardless of age, prostate volume, or baseline erectile function. Conclusion: No changes were observed in sexual and ejaculatory function of patients with iTind regardless of a man's age, prostate volume, and baseline sexual function. Clinicaltrials.gov: NCT02506465.


Subject(s)
Erectile Dysfunction , Lower Urinary Tract Symptoms , Prostatic Hyperplasia , Aged , Humans , Male , Middle Aged , Erectile Dysfunction/etiology , Lower Urinary Tract Symptoms/surgery , Prostatic Hyperplasia/complications , Prostatic Hyperplasia/surgery , Treatment Outcome
2.
Urology ; 153: 270-276, 2021 07.
Article in English | MEDLINE | ID: mdl-33373708

ABSTRACT

OBJECTIVE: To report the results of a multicenter, randomized, controlled trial with a temporarily implanted nitinol device (iTind; Medi-Tate Ltd, Hadera, Israel) compared to sham for the treatment of lower urinary tract symptoms secondary to benign prostatic hyperplasia. MATERIALS AND METHODS: Men 50 years or older were randomized 2:1 between iTind and sham procedure arms. A self-expanding, temporary nitinol device was placed for 5-7 days and an 18F Foley catheter was inserted and removed for the iTind and sham group, respectively. Patients were assessed at baseline, 1.5, 3, and 12 months postoperatively using the IPSS, peak urinary flow rate, residual urine, quality of life, and the International Index of Erectile Function. Unblinding occurred at 3 months. RESULTS: A total of 175 men (mean age 61.1 ± 6.5) participated (118 iTind vs 57 sham). A total of 78.6% of patients in the iTind arm showed a reduction of ≥3 points in IPSS, vs 60% of patients in the control arm at 3 months. At 12 months, the iTind group reported a 9.25 decrease in IPSS (P< .0001), a 3.52ml/s increase in peak urinary flow rate (P < .0001) and a 1.9-point reduction in quality of life (P < .0001). Adverse events were typically mild and transient, most Clavien-Dindo grade I or II, in 38.1% of patients in the iTind arm and 17.5% in the control arm. No de novo ejaculatory or erectile dysfunction occurred. CONCLUSION: Treatment with the second-generation iTind provided rapid and sustained improvement in lower urinary tract symptoms for the study period while preserving sexual function.


Subject(s)
Alloys , Lower Urinary Tract Symptoms/surgery , Prostatic Hyperplasia/complications , Prostheses and Implants , Humans , Lower Urinary Tract Symptoms/etiology , Male , Middle Aged , Prospective Studies , Single-Blind Method