Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiothorac Vasc Anesth ; 26(3): 381-6, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22459928

ABSTRACT

OBJECTIVE: The authors hypothesized that variations in electrocardiographically derived R-wave amplitude might be correlated with mechanical ventilation-induced variations in stroke volume as determined by transesophageal echocardiography. DESIGN: Observational prospective study. SETTING: Single university hospital. PARTICIPANTS: Thirty-four patients undergoing coronary artery bypass surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Respiratory R-wave variations in lead II (ΔRII) were correlated with aortic velocity time integral variations (r = 0.82, p < 0.0001). Respiratory R-wave variations in leads III and aVF and pulse pressure variation also were correlated with aortic velocity time integral variations (r = 0.49, p = 0.015; r = 0.61, p = 0.0016; and r = 0.72, p < 0.0001, respectively). R-wave respiratory variations in lead V(5) were not correlated with aortic velocity time integral variations. ΔRII was correlated with pulse pressure variation (r = 0.71, p < 0.0001). A ΔRII cutoff value of 15% accurately predicted stroke volume variations >15%, with a specificity of 92%, a sensitivity of 86%, a positive likelihood ratio of 11.1, a negative likelihood ratio of 0.15, a positive predictive value of 95%, and a negative predictive value of 80%. CONCLUSIONS: ΔRII is correlated with stroke volume variations as determined by transesophageal echocardiography in mechanically ventilated patients and can identify the stroke volume variation cutoff of 15%, previously determined to be the cutoff for volume responsiveness.


Subject(s)
Coronary Artery Bypass , Monitoring, Intraoperative/methods , Respiratory Mechanics/physiology , Stroke Volume/physiology , Adult , Aged , Aged, 80 and over , Aorta/physiopathology , Blood Flow Velocity/physiology , Blood Pressure/physiology , Echocardiography, Transesophageal/methods , Electrocardiography/methods , Female , Hemodynamics/physiology , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Respiration, Artificial
2.
Crit Care Med ; 37(9): 2570-5, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19623051

ABSTRACT

OBJECTIVES: To determine whether peak systolic velocity of tricuspid annular motion assessed by tissue Doppler echocardiography (Sta), a right ventricular function parameter, can discriminate patients with true- and false-positive pulse pressure variation. Pulse pressure variation is used to predict fluid responsiveness in mechanically ventilated patients. However, this parameter has been reported to be falsely positive, especially in patients with right ventricular dysfunction. DESIGN: A prospective study. SETTING: Medical and surgical intensive care unit of a university hospital. PATIENTS: Thirty- five mechanically ventilated patients hospitalized for >24 hrs with a pulse pressure variation of >12%. INTERVENTIONS: Doppler echocardiography (including measurement of Sta and stroke volume) was performed before and after infusion of 500 mL of colloid solution. Patients were classified into two groups according to their response to fluid infusion: responders (at least 15% increase in stroke volume) and nonresponders. MEASUREMENTS AND MAIN RESULTS: Twenty-three patients (66%) were responders (true-positive group) and 12 (34%) were nonresponders (false-positive group). Before volume expansion, Sta was statistically lower in the nonresponder group (0.13 [0.04] vs. 0.20 [0.05], p = .0004). The area under the curve of the receiver operating characteristic curve was 0.87 (95% confidence interval, 0.74-1). In patients with pulse pressure variation of >12%, a Sta cutoff value of 0.15 m/s discriminated between responders and nonresponders with a sensitivity of 91% (80-100) and a specificity of 83% (62-100). CONCLUSIONS: A Sta value of <0.15 m/s seems to be an accurate parameter to detect false-positive pulse pressure variation. Echocardiography should therefore be performed before fluid infusion in patients with pulse pressure variation of >12%.


Subject(s)
Echocardiography, Doppler , Pulse , Ventricular Function, Right , Aged , Critical Illness , False Positive Reactions , Female , Fluid Therapy , Humans , Male , Middle Aged , Prospective Studies , Systole
SELECTION OF CITATIONS
SEARCH DETAIL
...