Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Cancers (Basel) ; 14(14)2022 Jul 21.
Article in English | MEDLINE | ID: mdl-35884606

ABSTRACT

Endoscopic ultrasound-guided tissue acquisition (EUS-TA) of solid pancreatic tumors shows optimal specificity despite fair sensitivity, with an overall suboptimal diagnostic yield. We aim to quantify the adequacy and accuracy of EUS-TA and assess predictive factors for success, focusing on the presence and degree of specimen fibrosis. All consecutive EUS-TA procedures were retrieved, and the specimens were graded for sample adequacy and fibrosis. The results were evaluated according to patients' and tumor characteristics and the EUS-TA technique. In total, 407 patients (59% male, 70 [63-77] year old) were included; sample adequacy and diagnostic accuracy were 90.2% and 94.7%, respectively. Fibrosis was significantly more represented in tumors located in the head/uncinate process (p = 0.001). Tumor location in the head/uncinate (OR 0.37 [0.14-0.99]), number of needle passes ≥ 3 (OR 4.53 [2.22-9.28]), and the use of cell block (OR 8.82 [3.23-23.8]) were independently related to adequacy. Severe fibrosis was independently related to false negative results (OR 8.37 [2.33-30.0]). Pancreatic tumors located in the head/uncinate process showed higher fibrosis, resulting in EUS-TA with lower sample adequacy and diagnostic accuracy. We maintain that three or more needle passes and cell block should be done to increase the diagnostic yield.

3.
Dig Endosc ; 33(1): 118-124, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32333617

ABSTRACT

BACKGROUND AND AIM: In presence of malignant dysphagia, in patients unfit for surgery, the placement of a self-expandable metal stent (SEMS) represents a safe and effective palliative treatment. Esophageal stents (ES) present an over-the-wire mechanism where the stent is deployed under X-ray control. Recently a through-the-scope (TTS) ES was launched. The aim of our retrospective study is to assess the technical and clinical success of the new TTS-ES. MATERIALS AND METHODS: Patients with malignant dysphagia caused by esophageal cancer or ab-extrinsic compression, who underwent TTS esophageal stent in six Italian endoscopic referral centers, were retrospectively reviewed. RESULTS: A total of 40 patients were enrolled. TTS stent placement was successful in 39/40 patients (97.5%). 31 patients had an Ogilvie score of 4, nine an Ogilvie 3. After 2 weeks from stent placement 29 reported Ogilvie score of 0, eight a score of 1. None of the patients developed retrosternal pain requiring drugs. No patient experienced perforation, bleeding or migration. A total of seven patients (18%) developed dysphagia as late adverse event (AE). CONCLUSION: Through-the-scope ES presented less AEs, in terms of bleeding and perforation, if compared to the previous published data. An anti-migration system could be helpful, especially when the stent is placed for "ab-extrinseco" malignant dysphagia.


Subject(s)
Deglutition Disorders , Esophageal Neoplasms , Deglutition Disorders/etiology , Deglutition Disorders/surgery , Esophageal Neoplasms/complications , Esophageal Neoplasms/surgery , Humans , Palliative Care , Retrospective Studies , Stents , Treatment Outcome
4.
J Clin Gastroenterol ; 55(10): e87-e91, 2021.
Article in English | MEDLINE | ID: mdl-33060438

ABSTRACT

GOALS: The present survey from the Italian Society of Digestive Endoscopy (SIED-Società Italiana di Endoscopia Digestiva) was aimed at reporting infection control practice and outcomes at Digestive Endoscopy Units in a high-incidence area. BACKGROUND: Lombardy was the Italian region with the highest coronavirus disease-2019 (COVID-19) prevalence, at the end of March 2020 accounting for 20% of all worldwide deaths. Joint Gastro-Intestinal societies released recommendations for Endoscopy Units to reduce the risk of the contagion. However, there are few data from high-prevalence areas on adherence to these recommendations and on their efficacy. METHODS: A survey was designed by the Lombardy section of SIED to analyze (a) changes in activity and organization, (b) adherence to recommendations, (c) rate of health care professionals' (HCP) infection during the COVID-19 outbreak. RESULTS: In total, 35/61 invited centers (57.4%) participated; most modified activities were according to recommendations and had filtering face piece 2/filtering face piece 3 and water-repellent gowns available, but few had negative-pressure rooms or provided telephonic follow-up; 15% of HCPs called in sick and 6% had confirmed COVID-19. There was a trend (P=0.07) toward different confirmed COVID-19 rates among endoscopists (7.9%), nurses (6.6%), intermediate-care technicians (3.4%), and administrative personnel (2.2%). There was no correlation between the rate of sick HCPs and COVID-19 incidence in the provinces and personal protective equipment availability and use, whereas an inverse correlation with hospital volume was found. CONCLUSIONS: Adherence to recommendations was rather good, though a minority were able to follow all recommendations. Confirmed COVID-19 seemed higher among endoscopists and nurses, suggesting that activities in the endoscopy rooms are at considerable viral spread risk.


Subject(s)
COVID-19 , Endoscopy, Gastrointestinal , Humans , Infection Control , Italy/epidemiology , SARS-CoV-2
5.
Abdom Radiol (NY) ; 43(11): 2987-2990, 2018 11.
Article in English | MEDLINE | ID: mdl-29600432

ABSTRACT

PURPOSE: Post-surgical upper gastrointestinal anatomy may hamper a complete bilio-pancreatic evaluation with a standard echoendoscope. The aim of this study was to assess the role of catheter probe extraductal ultrasound (EDUS) for the evaluation of the common bile duct (CBD) in patients who are status post-gastric surgery and who are suspected of having choledocholithiasis. METHODS: We retrospectively analyzed patients with a prior history of gastric surgery, who underwent EDUS for a suspicion of CBD obstruction. For each patient, technical success, accuracy, and safety were recorded. In case of a positive finding of CBD stones, endoscopic retrograde cholangiopancreatography (ERCP) was performed. In case of other findings or a negative EDUS, computed tomography or magnetic resonance cholangiopancreatography (MRCP) was performed as appropriate. RESULTS: EDUS was technically successful in all the 11 patients with a Billroth II gastrectomy, while it failed in all the 5 patients with Roux-en-Y gastric surgery. EDUS accuracy was 100% (3 true-positive and 8 true-negative cases). CBD stones, confirmed and successfully extracted at ERCP, were found in two patients, while in one patient EDUS showed a CBD stenosis that was treated with a plastic stent during ERCP; computed tomography at follow-up was negative for cancer. EDUS was correctly negative in 8 patients, as confirmed by MRCP. CONCLUSIONS: EDUS may represent an accurate and safe alternative to standard endoscopic ultrasonography and MRCP for the detection of CBD stones in elderly patients who are status post-Billroth II gastric surgery.


Subject(s)
Choledocholithiasis/diagnostic imaging , Common Bile Duct/diagnostic imaging , Gastrectomy , Postoperative Complications/diagnostic imaging , Ultrasonography/methods , Aged , Aged, 80 and over , Cholangiopancreatography, Endoscopic Retrograde , Cholangiopancreatography, Magnetic Resonance , Female , Humans , Male , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed
7.
Chir Ital ; 59(5): 755-7, 2007.
Article in English | MEDLINE | ID: mdl-18019651

ABSTRACT

Rupture of the spleen after colonoscopy is a rare but dangerous complication; up to now only a few cases have been reported in the literature. This complication is more frequent in patients who have previously undergone abdominal surgery and after operative colonoscopies. This case report describes a 64-year-old man who complained of abdominal pain and dyspnoea some hours after a colonoscopy. Laboratory exams showed anaemia; the patient also developed hypotension and tachycardia; a CT scan revealed a splenic laceration with haemoperitoneum. A laparotomic splenectomy was successfully carried out.


Subject(s)
Colonoscopy/adverse effects , Hemoperitoneum/etiology , Splenectomy , Splenic Rupture/diagnosis , Splenic Rupture/etiology , Abdominal Pain/etiology , Dyspnea/etiology , Humans , Hypotension/etiology , Laparotomy , Male , Middle Aged , Splenic Rupture/complications , Splenic Rupture/surgery , Tachycardia/etiology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...