Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Bioinspir Biomim ; 11(5): 056014, 2016 09 13.
Article in English | MEDLINE | ID: mdl-27623216

ABSTRACT

The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles.


Subject(s)
Biomimetic Materials , Muscle, Skeletal/physiology , Robotics , Artificial Organs , Compliance/physiology , Humans , Models, Anatomic , Muscle Contraction/physiology , Muscle Fibers, Skeletal/physiology , Pressure
2.
Philos Trans A Math Phys Eng Sci ; 374(2074)2016 Aug 13.
Article in English | MEDLINE | ID: mdl-27402936

ABSTRACT

This paper reports the elastocaloric effect of two Cu-based shape memory alloys: Cu68Al16Zn16 (CuAlZn) and Cu73Al15Mn12 (CuAlMn), under compression at ambient temperature. The compression tests were conducted at two different rates to approach isothermal and adiabatic conditions. Upon unloading at a strain rate of 0.1 s(-1) (adiabatic condition) from 4% strain, the highest adiabatic temperature changes (ΔTad) of 4.0 K for CuAlZn and 3.9 K for CuAlMn were obtained. The maximum stress and hysteresis at each strain were compared. The stress at the maximum recoverable strain of 4.0% for CuAlMn was 120 MPa, which is 70% smaller than that of CuAlZn. A smaller hysteresis for the CuAlMn alloy was also obtained, about 70% less compared with the CuAlZn alloy. The latent heat, determined by differential scanning calorimetry, was 4.3 J g(-1) for the CuAlZn alloy and 5.0 J g(-1) for the CuAlMn alloy. Potential coefficients of performance (COPmat) for these two alloys were calculated based on their physical properties of measured latent heat and hysteresis, and a COPmat of approximately 13.3 for CuAlMn was obtained.This article is part of the themed issue 'Taking the temperature of phase transitions in cool materials'.

3.
Bioinspir Biomim ; 10(5): 055006, 2015 Sep 28.
Article in English | MEDLINE | ID: mdl-26414160

ABSTRACT

Pneumatic artificial muscles (PAMs) are actuators known for their high power to weight ratio, natural compliance and light weight. Due to these advantages, PAMs have been used for orthotic devices and robotic limbs. Small scale PAMs have the same advantages, as well as requiring greatly reduced volumes with potential application to prostheses and small scale robotics. The bladder of a PAM affects common actuator performance metrics, specifically: blocked force, free contraction, hysteresis, and dead-band pressure. This paper investigates the effect that bladder thickness has on static actuation performance of small scale PAMs. Miniature PAMs were fabricated with a range of bladder thicknesses to quantify the change in common actuator performance metrics specifically: blocked force, free contraction, and dead-band pressure. These PAMs were then experimentally characterized in quasi-static conditions, where results showed that increasing bladder wall thickness decreases blocked force and free contraction, while dead-band pressure increases. A nonlinear model was then applied to determine the structure of the stress-strain relationship that enables accurate modeling and the minimum number of terms. Two nonlinear models are compared and the identified parameters are analyzed to study the effect of the bladder thickness on the model.


Subject(s)
Artificial Organs , Biomimetics/instrumentation , Elastomers/chemistry , Muscle Contraction/physiology , Muscle, Skeletal/physiology , Robotics/instrumentation , Computer Simulation , Computer-Aided Design , Elastic Modulus , Equipment Design , Equipment Failure Analysis , Miniaturization , Models, Biological , Pressure , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...