Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Oper Dent ; 49(3): 325-335, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38632867

ABSTRACT

OBJECTIVES: This study aimed to evaluate the impact of various commercial silane brands with varied chemical compositions with or without the application of an adhesive layer on the microshear bond strength and durability of a resin luting agent to lithium disilicate glass ceramic. METHODS AND MATERIALS: Lithium disilicate glass ceramic discs (EMX, IPS e.max Press, Ivoclar Vivadent) measuring 10 mm in diameter and 3 mm in thickness were fabricated (n=240). Surfaces were etched using 5% hydrofluoric acid and randomly assigned to 10 groups based on the commercial brand of silane used (n=24): [RP] RelyX Ceramic Primer (3M ESPE); [PS] Prosil (FGM); [SA] Silano (Angelus); [SM] Silano (Maquira); [SU] Silane (Ultradent); [GL] GLUMA Ceramic Primer (Kulzer); [CB] Ceramic Bond (VOCO); [MB] Monobond N (Ivoclar Vivadent); [CP] Clearfil Ceramic Primer (Kuraray); and [DE] 2-step silane (Dentsply Sirona). Half of the EMXs (n=12) received a thin adhesive layer (+) after the silane and prior to resin luting agent, while the other half (n=12) did not receive an adhesive layer (-). For the microshear bond strength test (µSBS), four light-cured resin luting agent cylinders (1 mm in diameter) were created on each EMX surface. Half of these specimens were tested after 24 hours, while the other half were stored in deionized water for 6 months. The µSBS test was conducted using a universal testing machine (DL 500, EMIC) at a crosshead speed of 1 mm/min until failure. The obtained data underwent statistical analysis using analysis of variance (ANOVA) and the Tukey test (α=0.05). RESULTS: There was significant influence of the silane commercial brand on bond strength. Notably, "universal primers" yielded lower bond strength results compared to "pure" silane solutions. Water storage had a detrimental effect on microshear bond strength for certain silane commercial brands. Additionally, the application of an adhesive layer negatively impacted bond strength results for all silanes. CONCLUSIONS: This study confirms the importance of both silane commercial brand and chemical composition in relation to bond strength of resin luting agents to lithium disilicate glass ceramic. Furthermore, the application of an adhesive layer may have an adverse effect on bond stability over time.


Subject(s)
Ceramics , Dental Bonding , Dental Porcelain , Dental Stress Analysis , Materials Testing , Resin Cements , Shear Strength , Silanes , Dental Porcelain/chemistry , Silanes/chemistry , Ceramics/chemistry , Dental Bonding/methods , Resin Cements/chemistry , Surface Properties , Dental Cements/chemistry , Acid Etching, Dental/methods , Humans
2.
Oper Dent ; 48(6): 700-710, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37881098

ABSTRACT

OBJECTIVES: To evaluate the surface topography/roughness and bond strength of a resin luting agent to a lithium disilicate glass ceramic after etching with different concentrations of hydrofluoric acid (HF) and commercial brands. METHODS: For bond strength evaluation, 260 lithium disilicate glass ceramic (EMX) discs were randomly distributed into 13 groups based on concentrations of HF and commercial brands (n=20): 5% and 10%, Lysanda (LY5 and LY10); 5% and 10%, Maquira (MA5 and MA10); 5% and 10%, FGM (FG5 and FG10); 4.8%, Ivoclar Vivadent (IV5); 5% and 10%, PHS do Brasil (PH5 and PH10); 5% and 10%, BM4 (BM5 and BM10); 9%, Ultradent Inc (UL10); and Dentsply (DE10). A further random distribution (n=10) was made based on the application (+) or absence (-) of an adhesive layer. Resin luting agent cylinders (1 mm in diameter) were added on EMX surfaces, light-cured, and stored for 24 hours in deionized water at 37°C. On a universal testing machine (DL 500, EMIC), specimens were submitted to a microshear bond strength test at a crosshead speed of 1 mm/min until failure. A representative etched EMX disc from each group underwent surface topography analysis using field-emission scanning electron microscopy (n=1), and five (n=5) etched EMX discs from each group were tested for surface roughness. Data were statistically analyzed using analysis of variance and Tukey test (α=0.05). RESULTS: A less conditioned and smoother surface was observed for 5% HF compared to 10%. Additionally, commercial brands of HF were shown to affect bond strength. When the adhesive layer was not used (-), a 10% concentration promoted higher bond strengths to EMX. However, when adhesive was applied (+), the concentrations of HF and commercial brands had no effect on bond strength results. CONCLUSIONS: A 10% concentration of HF results in higher bond strength than a 5% concentration. If an adhesive layer is applied, neither this distinction nor the influence of commercial brands is observed.


Subject(s)
Dental Bonding , Hydrofluoric Acid , Hydrofluoric Acid/chemistry , Dental Cements , Surface Properties , Dental Bonding/methods , Materials Testing , Ceramics/chemistry , Dental Porcelain/chemistry , Resin Cements/chemistry , Silanes
3.
Oper Dent ; 47(6): E264-E272, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36322401

ABSTRACT

OBJECTIVES: To evaluate the bond strength of a resin luting agent to a lithium disilicate glass-ceramic after the use of different fit-checking materials and cleaning protocols. METHODS AND MATERIALS: Two hundred and forty-two (242) ceramic specimens were etched with 5% hydrofluoric acid for 20 seconds and distributed into 22 groups (n=10), in total. Four (4) groups were created based on fit-checking material and that had no following cleaning protocol: no fit-checking material used (control group); articulating paper; articulating spray; and fit-checker liquid. For each fit-checking material (3), 6 cleaning protocols were tested creating an additional 18 groups (n=10): air/water spray; 70% alcohol (ethanol); acetone; 35% phosphoric acid; 5% hydrofluoric acid; and a commercially available cleaning paste (Ivoclean, Ivoclar Vivadent). Silane and bonding resin were applied to all ceramic surfaces. Resin luting agent cylinders (1 mm in diameter) were created using silicone matrices, light-cured, and specimens were stored in deionized water at 37°C for 24 hours. Microshear bond strength test (µSBS) was performed on a universal testing machine (DL 500, EMIC) at a crosshead speed of 1 mm/min until failure. Results were statistically analyzed using ANOVA and Tukey's test (α=0.05). RESULTS: Articulating paper and fit-checker liquid, when not properly removed, negatively affected the bond strength (p<0.05). None of the tested cleaning protocols were effective for articulating paper (p<0.05). There was no significant difference in bond strength after the cleaning protocols between articulating spray and fit-checker liquid when compared to the control group (no contamination) (p>0.05). CONCLUSION: The cleaning protocols tested can effectively restore the bond strength of resin luting agents to lithium disilicate ceramics that were exposed to articulating spray or fit-checker liquid. The use of articulating paper is not recommended for fit-checking indirect lithium disilicate restorations.


Subject(s)
Dental Bonding , Hydrofluoric Acid , Hydrofluoric Acid/chemistry , Dental Bonding/methods , Dental Stress Analysis , Materials Testing , Dental Porcelain/therapeutic use , Dental Porcelain/chemistry , Ceramics/therapeutic use , Ceramics/chemistry , Resin Cements/therapeutic use , Resin Cements/chemistry , Silanes/chemistry , Water/chemistry , Surface Properties
4.
Oper Dent ; 47(2): E81-E90, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35405008

ABSTRACT

The purposes of this study were to 1) evaluate the effectiveness of different cleaning methods from a previously etched and silanized lithium disilicate glass ceramic (EMX) surface after contact with organic fluids (saliva or human blood) and 2) assess the effect of applying a new silane layer after the cleaning methods on the microshear bond strength (mSBS) of resin cement to EMX. EMX discs were etched with 5% hydrofluoric acid (HF) and properly silanized. Three control groups were created (n=10): control (without contamination), saliva positive, and human blood positive. Later, after new contaminations, the samples were distributed into four groups according to the cleaning method (n=20): air-water spray (AWS), 35% phosphoric acid, 70% alcohol, or Ivoclean cleaning paste. After the cleaning methods, subgroups were submitted to a new silane layer application, or not (n=10). All samples received a thin layer of a bonding agent and, subsequently, three light-cured resin cement cylinders were prepared on each EMX surface for the mSBS test. This test was performed on a universal testing machine at a vertical speed of 1 mm/minute until rupture. Contaminated and cleaned silanized EMX surfaces were assessed by scanning electron microscopy (SEM) (n=1). The noncontaminated control group showed an average mSBS of 18.7 MPa, and the positive saliva and human blood control groups yielded a 34% and 42% reduction in bond strength, respectively, compared to the uncontaminated control (p<0.05). For saliva-contaminated surfaces, all cleaning methods were effective and not different from one another or the control group (p>0.05). However, for human blood contamination, only Ivoclean cleaning paste was effective in restoring µSBS to uncontaminated control group levels (p>0.05). SEM images showed a clean surface (ie, with no contaminant residues) after the cleaning methods, regardless of the organic contaminant type. All the assessed cleaning methods were effective in removing saliva from the silanized EMX surface; however, only Ivoclean was able to restore the adhesion quality when the silanized EMX surface was contaminated with human blood.


Subject(s)
Dental Bonding , Resin Cements , Ceramics/chemistry , Dental Bonding/methods , Dental Porcelain/chemistry , Dental Stress Analysis , Humans , Hydrofluoric Acid/chemistry , Materials Testing , Resin Cements/chemistry , Silanes , Surface Properties
5.
Oper Dent ; 46(3): 237b-245, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34437705

ABSTRACT

Adequate removal of residual bonded materials from the enamel surface after orthodontic bracket debonding is critical, since any remaining composite may compromise enamel surface morphology and esthetics. The following clinical case reports present the association of at-home dental bleaching using 10% carbamide peroxide and the removal of residual bonded material using a super fine, tapered diamond bur followed by the use of an enamel microabrasion product after orthodontic bracket debonding. The proposed treatment considerably improved the esthetics and successfully removed the grooves created during the removal of the bonding composite, resulting in a smooth enamel surface.


Subject(s)
Dental Bonding , Orthodontic Brackets , Dental Enamel , Enamel Microabrasion , Humans , Orthodontic Brackets/adverse effects , Surface Properties
6.
Oper Dent ; 45(4): 343-351, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32053452

ABSTRACT

CLINICAL RELEVANCE: Total-etch adhesive systems and resin composite are clinically viable dental materials for esthetic restorations in teeth presenting white/yellow/brown hypomineralization stains. SUMMARY: Molar-incisor hypomineralization (MIH) is a condition that negatively affects enamel and dentin, especially the first molars and permanent incisors, causing esthetic and functional problems. The present clinical case report presents and discusses the etiology and clinical characteristics of MIH and describes a restorative protocol for MIH-affected teeth.


Subject(s)
Dental Enamel Hypoplasia , Composite Resins , Dental Enamel , Humans , Incisor , Molar
7.
Oper Dent ; 44(6): 566-573, 2019.
Article in English | MEDLINE | ID: mdl-30702410

ABSTRACT

The present clinical case report describes the clinical steps of enamel microabrasion associated with dental bleaching to restore severely-pitted fluorosed teeth. The process of removing the fluorotic superficial stains started by using macroabrasion with a water-cooled fine tapered 3195 FF diamond bur. Rubber dam isolation of the operative field was used to remove the remaining enamel stains and superficial irregularities with the Opalustre microabrasive compound (6.6% hydrochloric acid associated with silicon carbide particles) followed by polishing using fluoridated paste and subsequent 2% neutral fluoride gel topical application. After one month, dental bleaching was performed using 10% carbamide peroxide in custom-formed acetate trays for two hours/day for 42 days. The association of enamel microabrasion with dental bleaching was effective for reestablishing the dental esthetics of a patient with severe dental fluorosis.


Subject(s)
Fluorosis, Dental , Tooth Bleaching , Tooth Discoloration , Dental Enamel , Enamel Microabrasion , Humans
8.
Oper Dent ; 43(2): 190-200, 2018.
Article in English | MEDLINE | ID: mdl-29504887

ABSTRACT

AIM: To investigate the effect of different toothpaste formulations used prior to dental bleaching with 35% hydrogen peroxide (HP) on the mineral content and surface morphology of enamel. METHODS: Seventy bovine enamel blocks (4×4×2 mm) were submitted to in vitro treatment protocols using a toothbrushing machine prior to dental bleaching or a placebo procedure (n=10) as proposed in the following groups: unbleached control (PLA), bleached control (HP), and brushing with differing toothpastes prior to HP bleaching, including: potassium nitrate toothpaste containing sodium fluoride (PN), sodium monofluorophosphate/MFP toothpaste (FT), arginine-carbonate (8% arginine) (PA) or arginine-carbonate (1.5% arginine) toothpaste (SAN), and toothpaste containing bioactive glass (NM). Phosphorus concentration in gel ([P]) was evaluated (µg of P/mg of gel), and the elemental levels (wt%) of Ca, P, and Na as well as the proportion between Ca and P and spectra graphics were determined using an energy-dispersive X-ray spectrometer (EDS). The surface morphology was assessed using scanning electron microscopy (SEM). The data were subjected to analysis of variance and the Tukey test (α=0.05). RESULTS: HP demonstrated the greatest [P] values in gel, being statistically different from PLA. The [P] of NM was statistically similar to PLA. HP showed a significant decrease in the Ca% and Ca/P values when compared to PLA in EDS analysis. PA showed Ca/P values statistically different from HP. In accordance with SEM analysis, the PA, SAN, and NM groups presented a smooth and uniform enamel surface, while HP and FT demonstrated some alterations in morphology. CONCLUSION: The toothpastes containing bioactive glass or arginine carbonate used prior to dental bleaching were effective in protecting enamel against mineral loss promoted by the whitening procedure.


Subject(s)
Dental Enamel/drug effects , Tooth Bleaching Agents/adverse effects , Tooth Bleaching/adverse effects , Tooth Demineralization/chemically induced , Tooth Demineralization/prevention & control , Toothpastes/chemistry , Animals , Cattle , In Vitro Techniques , Surface Properties
9.
Oper Dent ; 43(2): 121-127, 2018.
Article in English | MEDLINE | ID: mdl-29337645

ABSTRACT

This case describes a female patient with agenesis of the maxillary right lateral incisor, with her permanent canine in its position and the deciduous canine retained. Additionally, she presented with a maxillary left peg lateral incisor. To solve her functional and esthetic complaints, a multidisciplinary approach involving perio-restorative procedures was proposed. Periodontal surgeries were performed to align the gingival contour, and the restorative approach utilized ceramic veneers. At the 18-month clinical and radiographic follow-up, the treatment outcome was stable, with maintenance of the clinical results achieved and without any sign of deciduous tooth resorption.


Subject(s)
Anodontia/therapy , Cuspid/abnormalities , Dental Restoration, Permanent/methods , Esthetics, Dental , Incisor/abnormalities , Adolescent , Combined Modality Therapy , Dental Veneers , Female , Gingivoplasty , Humans , Maxilla , Smiling , Tooth, Deciduous
10.
Oper Dent ; 42(1): 10-18, 2017.
Article in English | MEDLINE | ID: mdl-27723424

ABSTRACT

Pit and fissure sealant is a clinical technique adopted to prevent caries lesion development. Ionomeric and/or resin-based materials are commonly used for this purpose. This article presents a case series of sealed teeth with 22-year follow-up evaluated by clinical, photographic, and microscopic analysis. In 1992, sixteen patients (9-14 years of age) had at least three teeth sealed with one of the following materials: resin-modified glass ionomer cement (RMGIC, Vitrebond or Fuji II LC) or polyacid-modified resin composite (PMRC, VariGlass VLC), totaling 86 sealed permanent teeth. After 22 years, 10 patients were recalled, representing 41 teeth. The retention of sealants was assessed by three methods: clinical analysis by visual inspection; photography; and scanning electron microscope (SEM) images and classified as retained (pits and fissures filled by sealant material); partially retained (pits and fissures partially filled by sealant material); or totally lost (no material was found in pits and fissures). The SEM images provided a higher number of retained sealants when compared with the clinical and photographic evaluations. Also, no totally lost scores were found with SEM analysis, regardless of the sealing material. No caries lesions were found. A fully or partially retained sealant in pits and fissures was capable of preventing caries lesions after 22 years within the patient pool analyzed.


Subject(s)
Glass Ionomer Cements/chemistry , Pit and Fissure Sealants/chemistry , Adolescent , Child , Composite Resins/chemistry , Female , Follow-Up Studies , Humans , Male , Microscopy, Electron, Scanning , Photography , Resins, Synthetic/chemistry , Surface Properties , Time Factors
11.
Oper Dent ; 41(1): 8-14, 2016.
Article in English | MEDLINE | ID: mdl-26266645

ABSTRACT

After bracket debonding, residual bonded material may be observed on the enamel surface. When not properly removed, this residual material can interfere with the surface smoothness of the enamel, potentially resulting in staining at the resin/enamel interface and contributing to biofilm accumulation. Clinical case reports demonstrate clinical procedures to remove residual bonded material after bracket debonding. A water-cooled fine tapered 3195 FF diamond bur was used to remove the residual bonded material. Subsequently, the enamel surface was treated with Opalustre microabrasive compound. After one week, overnight dental bleaching was initiated using 10% carbamide peroxide in custom-formed trays for four weeks. The enamel microabrasion technique was found to be effective for polishing the enamel surface and for reestablishing the dental esthetics associated with dental bleaching. Longitudinal clinical controls of other clinical cases are presented.


Subject(s)
Dental Enamel , Enamel Microabrasion , Esthetics, Dental , Follow-Up Studies , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...