Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Life Sci Space Res (Amst) ; 39: 52-58, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37945089

ABSTRACT

We detect regular particle showers in several compact pixel detectors, distributed over the International Space Station. These showers are caused by high energy galactic cosmic rays, with energies often in the 10 s of TeV or higher. We survey the frequency of these events, their dependence on location on ISS, and their independence of the location of ISS, on its orbit. The Timepix detectors used allow individual particle tracks to be resolved, providing a possibility to perform physical analysis of shower events, which we demonstrate. In terms of radiation dosimetry, these showers indicate certain possible limitations of traditional dosimetric measures, in that (a) the dose measured in small sensor may be less than that received in a larger distribution of matter, such as a human and (b) the spatial and temporal extent of these events represents a regime of poorly documented biological response.


Subject(s)
Cosmic Radiation , Radiation Monitoring , Space Flight , Humans , Radiation Dosage , Spacecraft , Radiometry
2.
Cancers (Basel) ; 15(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36831368

ABSTRACT

Early assessment of neoadjuvant systemic therapy (NAST) response for triple-negative breast cancer (TNBC) is critical for patient care in order to avoid the unnecessary toxicity of an ineffective treatment. We assessed functional tumor volumes (FTVs) from dynamic contrast-enhanced (DCE) MRI after 2 cycles (C2) and 4 cycles (C4) of NAST as predictors of response in TNBC. A group of 100 patients with stage I-III TNBC who underwent DCE MRI at baseline, C2, and C4 were included in this study. Tumors were segmented on DCE images of 1 min and 2.5 min post-injection. FTVs were measured using the optimized percentage enhancement (PE) and signal enhancement ratio (SER) thresholds. The Mann-Whitney test was used to compare the performance of the FTVs at C2 and C4. Of the 100 patients, 49 (49%) had a pathologic complete response (pCR) and 51 (51%) had a non-pCR. The maximum area under the receiving operating characteristic curve (AUC) for predicting the treatment response was 0.84 (p < 0.001) for FTV at C4 followed by FTV at C2 (AUC = 0.82, p < 0.001). The FTV measured at baseline was not able to discriminate pCR from non-pCR. FTVs measured on DCE MRI at C2, as well as at C4, of NAST can potentially predict pCR and non-pCR in TNBC patients.

3.
Life Sci Space Res (Amst) ; 6: 69-78, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26256630

ABSTRACT

Progress in the development of high-performance semiconductor radiation imaging pixel detectors based on technologies developed for use in high-energy physics applications has enabled the development of a completely new generation of compact low-power active dosimeters and area monitors for use in space radiation environments. Such detectors can provide real-time information concerning radiation exposure, along with detailed analysis of the individual particles incident on the active medium. Recent results from the deployment of detectors based on the Timepix from the CERN-based Medipix2 Collaboration on the International Space Station (ISS) are reviewed, along with a glimpse of developments to come. Preliminary results from Orion MPCV Exploration Flight Test 1 are also presented.


Subject(s)
Cosmic Radiation , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiometry/methods , Thermoluminescent Dosimetry/methods , Equipment Design , Radiation Dosage , Space Flight , Spacecraft
SELECTION OF CITATIONS
SEARCH DETAIL
...