Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Emerg Med ; 63: 180.e1-180.e3, 2023 01.
Article in English | MEDLINE | ID: mdl-36336537

ABSTRACT

Crowned dens syndrome is characterized by severe neck pain with stiffness of the neck, sometime febrile, due to calcification of the transverse atlas ligament. We describe the case of a 65-year-old woman referred to the emergency department with a suspicion of meningitis. Several anamnestic and clinical signs ruled out this hypothesis. Re-evaluation of the CT images enabled us to reach the final diagnosis of crowned dens syndrome.


Subject(s)
Emergency Service, Hospital , Humans , Aged
2.
Eur Radiol ; 30(4): 1866-1875, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31811430

ABSTRACT

OBJECTIVES: To compare the diagnostic accuracy of 3D versus 2D contrast-enhanced vessel-wall (CE-VW) MRI of extracranial and intracranial arteries in the diagnosis of GCA. METHODS: This prospective two-center study was approved by a national research ethics board and enrolled participants from December 2014 to October 2017. A protocol including both a 2D and a 3D CE-VW MRI at 3 T was performed in all patients. Two neuroradiologists, blinded to clinical data, individually analyzed separately and in random order 2D and 3D sequences in the axial plane only or with reformatting. The primary judgment criterion was the presence of GCA-related inflammatory changes of extracranial arteries. Secondary judgment criteria included inflammatory changes of intracranial arteries and the presence of artifacts. A McNemar's test was used to compare 2D to 3D CE-VW MRIs. RESULTS: Seventy-nine participants were included in the study (42 men and 37 women, mean age 75 (± 9.5 years)). Fifty-one had a final diagnosis of GCA. Reformatted 3D CE-VW was significantly more sensitive than axial-only 3D CE-VW or 2D CE-VW when showing inflammatory change of extracranial arteries: 41/51(80%) versus 37/51 (73%) (p = 0.046) and 35/50 (70%) (p = 0.03). Reformatted 3D CE-VW was significantly more specific than 2D CE-VW: 27/27 (100%) versus 22/26 (85%) (p = 0.04). 3D CE-VW showed higher sensitivity than 2D CE-VW when detecting inflammatory changes of intracranial arteries: 10/51(20%) versus 4/50(8%), p = 0.01. Interobserver agreement was excellent for both 2D and 3D CE-VW MRI: κ = 0.84 and 0.82 respectively. CONCLUSIONS: 3D CE-VW MRI supported more accurate diagnoses of GCA than 2D CE-VW. KEY POINTS: • 3D contrast-enhanced vessel-wall magnetic resonance imaging is a high accuracy, non-invasive diagnostic tool used to diagnose giant cell arteritis. • 3D contrast-enhanced vessel-wall imaging is feasible for clinicians to complete within a relatively short time, allowing immediate assessment of extra and intracranial arteries. • 3D contrast-enhanced vessel-wall magnetic resonance imaging might be considered a diagnostic tool when intracranial manifestation of GCA is suspected.


Subject(s)
Giant Cell Arteritis/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Temporal Arteries/diagnostic imaging , Aged , Aged, 80 and over , Contrast Media , Female , Giant Cell Arteritis/pathology , Humans , Male , Middle Aged , Organometallic Compounds , Prospective Studies , Sensitivity and Specificity , Temporal Arteries/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...