Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
PeerJ Comput Sci ; 8: e964, 2022.
Article in English | MEDLINE | ID: mdl-35875629

ABSTRACT

The subjectiveness of multimedia content description has a strong negative impact on tag-based information retrieval. In our work, we propose enhancing available descriptions by adding semantically related tags. To cope with this objective, we use a word embedding technique based on the Word2Vec neural network parameterized and trained using a new dataset built from online newspapers. A large number of news stories was scraped and pre-processed to build a new dataset. Our target language is Portuguese, one of the most spoken languages worldwide. The results achieved significantly outperform similar existing solutions developed in the scope of different languages, including Portuguese. Contributions include also an online application and API available for external use. Although the presented work has been designed to enhance multimedia content annotation, it can be used in several other application areas.

2.
J Vasc Surg ; 69(3): 783-791, 2019 03.
Article in English | MEDLINE | ID: mdl-30292614

ABSTRACT

OBJECTIVE: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). METHODS: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. RESULTS: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). CONCLUSIONS: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.


Subject(s)
Aortic Aneurysm/surgery , Aortic Rupture/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Aged , Aged, 80 and over , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/mortality , Aortic Rupture/diagnostic imaging , Aortic Rupture/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Endoleak/diagnostic imaging , Endoleak/mortality , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Product Surveillance, Postmarketing , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stents , Time Factors , Treatment Outcome
3.
J Vasc Surg ; 69(5): 1444-1451, 2019 05.
Article in English | MEDLINE | ID: mdl-30477942

ABSTRACT

OBJECTIVE: Abdominal aortic aneurysm (AAA) management involves a decision process that takes into account anatomic characteristics, surgical risks, patients' preferences, and expected survival. Whereas larger AAA diameter has been associated with increased mortality after both standard endovascular aneurysm repair (EVAR) and open repair, it is unclear whether survival after EVAR is influenced by other anatomic characteristics. The purpose of this study was to determine the importance of baseline anatomic features on survival after EVAR. METHODS: All patients treated at a tertiary teaching center with EVAR for intact standard infrarenal AAA from 2000 to 2014 were included. The civil data registry was queried to determine survival status; causes of death were obtained from death certificates. The primary study end point was to determine the impact of baseline morphologic features on all-cause and cardiovascular mortality after EVAR. RESULTS: This study included 404 EVAR patients (12.1% women; mean age, 73 years) with a median follow-up of 5.8 years (interquartile range, 3.1-7.4 years). The 5- and 10-year overall survival rates for the entire population after EVAR were 70% (95% confidence interval [CI], 66%-75%) and 43% (95% CI, 37%-50%), respectively. Only AAA diameter >70 mm (hazard ratio [HR], 1.75; 95% CI, 1.20-3.56) was identified as an independent anatomic predictor of all-cause mortality. Death due to cardiovascular causes occurred in 60 (38.5%) patients. Aneurysm-related mortality was responsible for six of the cardiovascular-related deaths. In multivariable analysis, both neck diameter ≥30 mm (HR, 2.16; 95% CI, 1.05-4.43) and AAA diameter >70 mm (HR, 2.45; 95% CI, 1.34-4.46) were identified as independent morphologic risk factors for cardiovascular mortality, whereas >25% circumferential neck thrombus (HR, 0.32; 95% CI, 0.13-0.77) was protective. CONCLUSIONS: This study suggests that patients with AAA diameters >70 mm are at increased risk of all-cause and cardiovascular mortality. In addition, patients with infrarenal neck diameters ≥30 mm have a greater risk of cardiovascular mortality, although AAA-related deaths were not more frequent in this group of patients. Consequently, a more aggressive management of cardiovascular medical comorbidities may be warranted to improve survival after standard EVAR in these patients.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation/mortality , Cardiovascular Diseases/mortality , Computed Tomography Angiography , Endovascular Procedures/mortality , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Cardiovascular Diseases/diagnosis , Cause of Death , Comorbidity , Endovascular Procedures/adverse effects , Female , Humans , Male , Neoplasms/diagnosis , Neoplasms/mortality , Predictive Value of Tests , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
4.
J Vasc Surg ; 68(6): 1725-1735, 2018 12.
Article in English | MEDLINE | ID: mdl-29914837

ABSTRACT

OBJECTIVE: Severe neck angulation is associated with complications after endovascular aneurysm repair (EVAR). Newer endografts may overcome this limitation, but the literature lacks long-term results. We studied the long-term outcomes of EVAR in patients with severe neck angulation. METHODS: A retrospective case-control study of a prospective multicenter database was performed. All measurements were made with dedicated software with center lumen line reconstruction. A study group including patients with neck length >15 mm, infrarenal angle (ß) >75 degrees or suprarenal angle (α) >60 degrees, and neck length 10 to 15 mm with ß >60 degrees or α >45 degrees was compared with a control group matched for demographics and other morphologic neck features. The primary end point was type IA endoleak (EL1A). Secondary end points were freedom from neck-related secondary interventions, primary clinical success, and overall survival. RESULTS: Forty-five patients were included in the angulated neck group and compared with 65 matched patients. Median follow-up was 7.4 years (interquartile range, 4.8-8.5 years). In the angulated neck group, mean α was 51.4 degrees (±21.1 degrees) and the mean ß was 80.8 degrees (±15.6 degrees); in the nonangulated group, these were 17.9 degrees (±17.0 degrees) and 35.4 degrees (±20.0 degrees), respectively. At 7 years, five patients in the angulated neck group and two nonangulated patients developed EL1A, yielding a freedom from EL1A of 86.1% (n = 14; standard error [SE], 0.069) and 96.6% (n = 34; SE, 0.023), respectively (P = .056). After exclusion of a patient who developed an EL1A secondary to an endograft infection, this difference was significant: 86.1% (n = 14; SE, 0.069) in the angulated neck group and 98.2% (n = 34; SE, 0.018) in the nonangulated group (P = .016). At 7 years, freedom from neck-related secondary interventions was 91.7% (n = 14; SE, 0.059) and 91.6% (n = 29; SE, 0.029), respectively. The 7-year primary clinical success estimates were 41.2% (n = 11; SE, 0.085) and 56.6% (n = 20; SE, 0.072) for the angulated neck and nonangulated groups, respectively (P = .12). The 7-year survival rates were 44.3% (n = 18; SE, 0.076) vs 66.7% (n = 42; SE, 0.059) for the angulated neck and nonangulated groups, respectively (P = .25). Device integrity failure was not observed. CONCLUSIONS: Despite satisfactory results early and in the midterm, a higher rate of EL1A was identified among patients with severely angulated necks in the long term. However, mortality was not affected by this difference. These findings suggest that EVAR should be used judiciously in patients with extreme angulation of the proximal neck and highlight the need for close follow-up of EVAR, especially in the long term and in patients treated outside instructions for use.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Databases, Factual , Endoleak/etiology , Endoleak/mortality , Endoleak/surgery , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Netherlands , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
5.
Surg Innov ; 24(6): 598-604, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28871872

ABSTRACT

BACKGROUND: Usually laparoscopy is performed by means of a 2-dimensional (2D) image system and multiport approach. To overcome the lack of depth perception, new 3-dimensional (3D) systems are arising with the added advantage of providing stereoscopic vision. To further reduce surgery-related trauma, there are new minimally invasive surgical techniques being developed, such as LESS (laparoendoscopic single-site) surgery. The aim of this study was to compare 2D and 3D laparoscopic systems in LESS surgical procedures. MATERIALS AND METHODS: All participants were selected from different levels of experience in laparoscopic surgery-10 novices, 7 intermediates, and 10 experts were included. None of the participants had had previous experience in LESS surgery. Participants were chosen randomly to begin their experience with either the 2D or 3D laparoscopic system. The exercise consisted of performing an ex vivo pork cholecystectomy through a SILS port with the assistance of a fixed distance laparoscope. Errors, time, and participants' preference were recorded. Statistical analysis of time and errors between groups was conducted with a Student's t test (using independent samples) and the Mann-Whitney test. RESULTS: In all 3 groups, the average time with the 2D system was significantly reduced after having used the 3D system ( P < .05). In the postexercise questionnaire, two thirds of participants showed a preference for using the 3D system. CONCLUSION: This study suggests that the 3D system may improve the learning curve and that learning from the 3D system is transferable to the 2D environment. Additionally, the majority of participants prefer 3D equipment.


Subject(s)
Clinical Competence , Imaging, Three-Dimensional , Laparoscopy , Liver/surgery , Surgery, Computer-Assisted , Animals , Depth Perception , Laparoscopes , Learning Curve , Liver/diagnostic imaging , Models, Animal , Swine
6.
Rev Port Cir Cardiotorac Vasc ; 24(3-4): 171, 2017.
Article in English | MEDLINE | ID: mdl-29701401

ABSTRACT

INTRODUCTION: Hepatic artery aneurysms (HAAs) are rare, representing about 0.1-2% of all arterial aneurysms. They are the second most common splanchnic aneurysms, after splenic artery aneurysms. They have the highest rate of rupture among all splanchnic artery aneurysms and frequently become symptomatic. METHODS: To present a case of a hepatic artery aneurysm treated by endovascular technique. RESULTS: A 65-year old man who had a medical history of hypertension, dyslipidemia and smoking, with an incidental finding on a CT imaging of a hepatic artery aneurysm (maximum diameter 75mm) was admitted for selective arteriography and treatment. He was asymptomatic. We proceeded to aneurysm exclusion with a self-expandable covered stent (Viabahn®) 6x100mm. Final angiography revealed permeability of right hepatic artery, splenic artery and gastroduodenal artery, and no visible endoleaks. He was discharged on the 4th postoperative day, asymptomatic and without analytic changes. On a 6 months follow-up, CT-angio confirmed a fully patent stent with no visible endoleaks and complete aneurysm exclusion. CONCLUSION: HAAs should be diagnosed before rupture. Abdominal pain, bleeding or compression may be the first symptoms. Exclusion by endovascular techniques, namely through covered- stent use, may be a good option.


Subject(s)
Aneurysm , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Hepatic Artery , Aged , Aneurysm/surgery , Hepatic Artery/surgery , Humans , Male , Splenic Artery , Stents , Treatment Outcome
7.
Rev Port Cir Cardiotorac Vasc ; 24(3-4): 182, 2017.
Article in English | MEDLINE | ID: mdl-29701411

ABSTRACT

INTRODUCTION: Brachial artery aneurysms are relatively uncommon and generally due to infectious, post-traumatic or iatrogenic etiology. They seem to affect 4.5% of arteriovenous fistula. The usual manifestation is an accidental finding of a pulsatile, painless, and asymptomatic mass. Complications include sac thrombosis, thromboembolic ischaemic events, and disruption with profuse bleeding. METHODS: The aim of this study is to present a case of true brachial artery aneurysm in end-stage renal disease patient after arteriovenous fistula creation. RESULTS: Sixty-six-year-old men with a past medical history of hypertension, dyslipidemia, smoking and poliquistic renal disease. He started a hemodialysis program in March 2006, using a brachiocephalic fistula on the left upper limb, built in February 2005. Submitted to kidney transplant in June 2010 and subsequent fistula ligation in December 2012. He goes to the emergency service in June 2016 with a pulsatile mass on the medial aspect of the left arm. Pain, redness and heat were present. Radial pulse was palpable. Inflammatory parameters were high and ultrasound revealed a fusiform aneurysm of the brachial artery with partial thrombosis and triphasic flow. An MRI was performed, documenting a brachial artery aneurysm, with 44mm greatest diameter and an extension of 17.5cm. Patient was hospitalized under antibiotic therapy and submitted to a reversed great saphenous vein interposition graft. Discharge from hospital occurred on the 7th postoperative day, with no sensitive or motor deficits and a present radial pulse. CONCLUSION: Arterial aneurysm is a rare, but significant complication long after the creation of a hemodialysis access. High flow, immunosuppression and increased resistance following ligation of the AV fistula may accelerate this process.


Subject(s)
Aneurysm , Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Aged , Aneurysm/etiology , Aneurysm/surgery , Arteriovenous Shunt, Surgical/adverse effects , Brachial Artery/pathology , Humans , Male , Renal Dialysis , Treatment Outcome
8.
World J Gastroenterol ; 20(36): 13191-4, 2014 Sep 28.
Article in English | MEDLINE | ID: mdl-25278716

ABSTRACT

Ileal intussusception is the invagination of the small intestine within itself and accounts for 1% of cases of acute obstruction. However, physicians do not initially consider intussusception as a possible diagnosis of obstruction due to its rarity in adults. Herein, we report the case of a 22-year-old male who was admitted to the Emergency Department with continuous abdominal pain. Ultrasonography and computed tomography revealed an ileal intussusception. The patient underwent surgical removal of the segment of the small bowel. Unexpectedly, pathology revealed that the invagination occurred due to a parasite egg, with features suggestive of Schistosoma species. Schistosomiasis, although considered a parasitic disease in tropical countries, is not absent from Europe and though it is highly improbable, it may be responsible for cases of intussusception in adults.


Subject(s)
Ileal Diseases/parasitology , Intestinal Diseases, Parasitic/parasitology , Intussusception/parasitology , Ovum , Schistosoma/isolation & purification , Schistosomiasis/parasitology , Animals , Biopsy , Humans , Ileal Diseases/diagnosis , Ileal Diseases/surgery , Intestinal Diseases, Parasitic/complications , Intestinal Diseases, Parasitic/diagnosis , Intestinal Diseases, Parasitic/surgery , Intussusception/diagnosis , Intussusception/surgery , Male , Schistosomiasis/complications , Schistosomiasis/diagnosis , Schistosomiasis/surgery , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
9.
Nucleic Acids Res ; 42(Database issue): D408-14, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24214987

ABSTRACT

Unified Human Interactome (UniHI) (http://www.unihi.org) is a database for retrieval, analysis and visualization of human molecular interaction networks. Its primary aim is to provide a comprehensive and easy-to-use platform for network-based investigations to a wide community of researchers in biology and medicine. Here, we describe a major update (version 7) of the database previously featured in NAR Database Issue. UniHI 7 currently includes almost 350,000 molecular interactions between genes, proteins and drugs, as well as numerous other types of data such as gene expression and functional annotation. Multiple options for interactive filtering and highlighting of proteins can be employed to obtain more reliable and specific network structures. Expression and other genomic data can be uploaded by the user to examine local network structures. Additional built-in tools enable ready identification of known drug targets, as well as of biological processes, phenotypes and pathways enriched with network proteins. A distinctive feature of UniHI 7 is its user-friendly interface designed to be utilized in an intuitive manner, enabling researchers less acquainted with network analysis to perform state-of-the-art network-based investigations.


Subject(s)
Databases, Protein , Protein Interaction Mapping , Disease , Gene Expression , Genes , Genomics , Humans , Internet , Molecular Sequence Annotation , Pharmaceutical Preparations/chemistry , Phenotype , Proteins/chemistry , Proteins/genetics , Proteins/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...