Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Publication year range
1.
J Ocul Pharmacol Ther ; 40(2): 111-116, 2024 03.
Article in English | MEDLINE | ID: mdl-38150537

ABSTRACT

Optic neuropathies, such as glaucoma, are some of the leading causes of irreversible blindness worldwide. There has been a lot of research for potential therapies that could attenuate and even reduce the impact of the pathological pathways that lead to the loss of retinal ganglion cells (RGCs). In recent years, vitamin B3 (nicotinamide) has gained some interest as a viable option for these neurodegenerative diseases due to its fundamental role in enhancing the mitochondria metabolism of the RGCs. This review focuses on elucidating the impact of vitamin B3 on retinal cells, especially when in a dysfunctional state like what happens in optic neuropathies, especially glaucoma. This review also summarizes the existing and future research on the clinical effects of vitamin B3 in these optic neuropathies, and determines appropriate recommendations regarding its dosing, efficacy, and eventual side effects.


Subject(s)
Glaucoma , Optic Nerve Diseases , Humans , Optic Nerve Diseases/drug therapy , Optic Nerve Diseases/etiology , Glaucoma/metabolism , Retinal Ganglion Cells/metabolism , Vitamins , Dietary Supplements
2.
Eur J Ophthalmol ; 30(1): 112-118, 2020 Jan.
Article in English | MEDLINE | ID: mdl-30360660

ABSTRACT

PURPOSE: The aim of this study is to assess the agreement between manual and automated gonioscopy for iridocorneal angle opening. METHODS: The research is a cross-sectional observational study. Manual and automated gonioscopy were performed to consecutive patients in a glaucoma clinic. Iridocorneal angle opening grading was performed according to Shaffer's classification. Automated gonioscopy was performed with NGS-1 automated gonioscope (NIDEK Co., Gamagori, Japan). The automated gonio-photos were graded by two independent observers. Agreement between automated and manual gonioscopy and also among raters was ascertained by Fleiss' kappa statistic and comparison of area under curve. RESULTS: In total, 88 eyes of 47 subjects were analysed. Mean age was 63 ± 10 years. Twenty eyes (22.7%) were excluded from grading due to poor quality images. Angle closure was detected in 23.4% with dynamic gonioscopy in comparison with 4.3% using automated image grading. The agreement for angle closure diagnosis between dynamic and automated gonioscopy was low (κ = 0.09 ± 0.10; p = 0.18). The area under curve for detecting eyes with angle closure showed poor accuracy between automated and manual methods (area under curve: 0.53 ± 0.05, 95% confidence interval: 0.44-0.62). There was modest inter-rater agreement for angle opening assessment of automated images with Fleiss' kappa of 0.17 (95% confidence interval: 0.035-0.238). CONCLUSION: Manual and automated gonioscopy showed only slight agreement for the assessment of iridocorneal angle opening status. Further improvements of the NGS-1 automated gonioscopy and technique are desired for widespread use in a real-life setting.


Subject(s)
Anterior Chamber/diagnostic imaging , Glaucoma/diagnosis , Gonioscopy/methods , Photography/methods , Adult , Aged , Aged, 80 and over , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , ROC Curve , Young Adult
3.
ACS Appl Bio Mater ; 2(10): 4173-4180, 2019 Oct 21.
Article in English | MEDLINE | ID: mdl-35021432

ABSTRACT

The patient's compliance on the therapeutics to treat glaucoma is significantly low contributing for a fast evolution of the disease. This article presents an autonomous system with controlled release using an alpha2-adrenergic receptor agonist, brimonidine, usually used to treat glaucoma. More specifically, biocompatible and layer-by-layer drug delivery films containing monolayers with brimonidine encapsulated in polymer-ß-cyclodextrin were prepared with the objective to obtain a system able to release precise amounts of drug at specific times. To delay the erosion-controlled drug release, we included nanosheets of graphene oxide and layers of a biodegradable polymer (poly-ß-aminoester) between the drug-containing monolayers to obtain a time-controlled drug delivery system. An increase in the number of graphene oxide layers is proportional to the brimonidine release delay and its kinetic release can be tuned as a function of the number of layers. Two types of films with brimonidine encapsulated in ß-cyclodextrin were analyzed. One of them composed of barrier layers with PBAE and another with two types of barrier layers, PBAE and graphene oxide. The results indicate that one graphene oxide bilayer can delay the brimonidine release for more than 24 h. In vitro assays confirmed that the films have a cell viability of 100%.

4.
J Curr Glaucoma Pract ; 12(3): 139-141, 2018.
Article in English | MEDLINE | ID: mdl-31354206

ABSTRACT

The XEN gel stent is an ab-interno minimally invasive glaucoma surgery device that reduces intraocular pressure by creating a subconjunctival drainage pathway. XEN intents to provide a safer and less invasive mean of lowering intraocular pressure. As with any new device, there is still some lack of experience and knowledge concerning efficacy, technique, and complications. We report a novel surgical approach for early bleb failure after XEN implantation. HOW TO CITE THIS ARTICLE: Ferreira NP, Pinto JM, Teixeira F, Pinto LA. XEN Gel Stent Early Failure-dye-enhanced Ab-externo Revision. J Curr Glaucoma Pract 2018;12(3):139-141.

5.
J Glaucoma ; 25(5): e531-5, 2016 05.
Article in English | MEDLINE | ID: mdl-27120136

ABSTRACT

PURPOSE: To evaluate the safety profile and possible change in corneal astigmatism following trabeculectomy with a fornix-based conjunctival flap which is closed with 4 corneal groove-embedded sutures. MATERIALS AND METHODS: Patients scheduled for a primary trabeculectomy were included in this single center, prospective trial between February and April 2013. Refractive status was assessed with an automated refractokeratometer preoperatively and at months 1, 3, 6, and 18 postoperatively, together with clinical assessment of intraocular pressure, visual acuity, postoperative complications, and medication use. Preoperative and postoperative variables were compared using paired samples t tests and vector analysis for corneal astigmatism change was performed. RESULTS: Forty-four eyes of 44 patients were included. Vector analysis showed a transient significant with-the-rule shift in astigmatism without influence on spherical equivalent. Visual acuity was transiently reduced in the first month but recovered to preoperative values with no need to change optical correction. Two patients developed postoperative wound leakage, which was successfully treated with a bandage corneoscleral contact lens. CONCLUSIONS: Trabeculectomy with a fornix-based conjunctival flap closed by 4 corneal groove-embedded sutures results in a low complication rate. This safe suturing technique induces a transient shift of with-the-rule astigmatism, reverting to the preoperative values within 3 months of surgery. Adjustments to refractive correction are recommended to be postponed until after this period.


Subject(s)
Astigmatism/prevention & control , Conjunctiva/surgery , Glaucoma/surgery , Surgical Flaps , Trabeculectomy/methods , Aged , Aged, 80 and over , Female , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Prospective Studies , Suture Techniques , Tonometry, Ocular , Visual Acuity
6.
Buenos Aires; EUDEBA; 1a. ed; 1963. 234 p. ^e18 cm.
Monography in Spanish | LILACS-Express | BINACIS | ID: biblio-1197520
7.
Buenos Aires; Paidós; 1a. ed; 1973. 19 p. ^e22,5 cm.(Textos Universitarios Sociología y Política, 10).
Monography in Spanish | LILACS-Express | BINACIS | ID: biblio-1198902
8.
Buenos Aires; Paidós; 1a. ed; 1973. 19 p. 22,5 cm.(Textos Universitarios Sociología y Política, 10). (73821).
Monography in Spanish | BINACIS | ID: bin-73821
9.
Buenos Aires; EUDEBA; 1a. ed; 1963. 234 p. 18 cm. (72118).
Monography in Spanish | BINACIS | ID: bin-72118
SELECTION OF CITATIONS
SEARCH DETAIL
...