Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Int J Lab Hematol ; 39(6): 663-670, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28990291

ABSTRACT

INTRODUCTION: Recent automated hematology analyzers (HAs) can identify and report nucleated red blood cells (NRBC) count as a separate population out of white blood cells (WBC). The aim of this study was to investigate the analytical performances of NRBC enumeration on five top of the range HAs. METHODS: We evaluated the within-run and between-day precision, limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) of XE-2100 and XN-module (Sysmex), ADVIA 2120i (Siemens), BC-6800 (Mindray), and UniCel DxH 800 (Beckman Coulter). Automated NRBC counts were also compared with optical microscopy (OM). RESULTS: The limits of detection for NRBC of the BC-6800, XN-module, XE-2100, UniCel DxH 800, and ADVIA 2120i are 0.035×109 /L, 0.019×109 /L, 0.067×109 /L, 0.038×109 /L, and 0.167×109 /L, respectively. Our data indicated excellent performance in terms of precision. The agreement with OM was excellent for BC-6800, XN-module, and XE-2100 (Bias 0.023, 0.019, and 0.033×109 /L, respectively). ADVIA 2120i displayed a significant constant error and UniCel DxH 800 both proportional and small constant error. CONCLUSION: Regards to NRBC counting, the performances shown by BC-6800, XN-module, and XE-2100 are excellent also a low count, ADVIA 2120i and UniCel DxH 800 need to be improved.


Subject(s)
Erythroblasts/pathology , Hematologic Tests/instrumentation , Female , Hematologic Tests/methods , Humans , Male
2.
Int J Lab Hematol ; 39(6): 645-652, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28975714

ABSTRACT

BACKGROUND: The aims of this study were to compare the diagnostic accuracy of blood smear review criteria, by means of three different panel rules, those proposed by: the International Consensus Group for Hematology [41-ICGH rules], the Italian Survey [IS rules] and the Working Group on Hematology-SIBioC (WGH) consensus rules (WGH rules). METHODS: This study is based on 2707 peripheral blood (PB) samples referred for routine hematological testing to the WGH-associated laboratories displaced all over the Italian territory. The PB samples were processed on seven different hematology analyzers (HAs): Advia 2120i, XE-2100, BC-6800, ABX Pentra, XN-1000, Cell-DYN Sapphire, and DxH800, respectively. All the results provided by the HAs were analyzed through the application of three different blood smear review criteria: that is, the 41-ICGH, IS, and WGH rules. Finally, data were compared with those obtained by optical microscopy (OM), as the current gold standard. RESULTS: The overall the agreement OM classification with ICGH, IS, and WGH panel rules is 0.83, 0.83, and 0.85, respectively. The false negatives are 2.1%, 3.0%, and 2.9%, while false positives are 15.1%, 13.7%, and 11.7%, respectively. All the seven HAs showed variable interinstrument performance, as three different criteria for OM review were adopted on each of them from time to time. CONCLUSION: These results presented show that the customization of validation rules is necessary for enhancing the quality of hematological testing and optimizing workflow.


Subject(s)
Hematologic Tests/instrumentation , Hematologic Tests/methods , Hematologic Tests/standards , Female , Humans , Italy , Male
3.
Int J Lab Hematol ; 37(2): 253-8, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25041897

ABSTRACT

INTRODUCTION: We aimed to identify simple but reliable indices for effective screening of spurious hemolysis in whole-blood specimens. METHODS: Thirteen inpatient whole-blood samples were divided in two aliquots. The former was left untreated, whereas the latter was mechanically hemolyzed by forced aspiration with an insulin syringe. All aliquots were tested on Siemens Advia 2120 and Sysmex XE-2100. The hemolysis index (HI) was also assessed in centrifuged plasma. RESULTS: The mechanical hemolysis generated a 4-40% decrease in red blood cells (RBCs). A statistically significant decrease was observed for hematocrit (Ht) and mean corpuscular volume (MCV), whereas mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and platelet count were increased. The values of hemoglobin (Hb) and white blood cells remained substantially unchanged. Two specific equations ([Ht/Hb] × âˆšMCV and [Ht/Hb] × 100) were developed. Both equations displayed an area under the curve of ≥0.99 for identifying spurious hemolysis, much greater than that of both RBC ghosts and immature platelet fraction. A highly significant correlation was also observed between results of these equations and percentage reduction in RBCs or HI increase. CONCLUSION: Provided that these results will be confirmed in further studies, these equations may provide a reliable means for screening spurious hemolysis in whole-blood samples.


Subject(s)
Blood Cell Count/methods , Erythrocyte Indices , Hemolysis , Adult , Aged , Aged, 80 and over , Blood Cell Count/instrumentation , Blood Cell Count/standards , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
5.
Int J Lab Hematol ; 35(2): 225-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23033911

ABSTRACT

INTRODUCTION: Nucleated red blood cells (NRBCs) and reticulocytes are early and important measures of red blood cells' (RBCs) turnover, but little is known on how spurious hemolysis may affect the reliability of these parameters. MATERIALS AND METHODS: Ten EDTA-anticoagulated samples were divided into three aliquots. The first was immediately tested, where-as the others (defined A and B) were mechanically hemolyzed by aspiration 5 and 10 times through a small-gauge needle. RBC, NRBC, and reticulocyte counts were performed on Sysmex XE-2100. RESULTS: An increasing amount of hemolysis was produced in hemolyzed aliquots A and B. The RBC and reticulocyte counts progressively decreased from the nonhemolyzed sample to hemolyzed aliquots 'A' and 'B'. The NRBC count increased in 3 of the 10 samples and decreased in the remaining seven. CONCLUSIONS: Hemolysis of venous blood samples may seriously jeopardize NRBC and reticulocyte counts.


Subject(s)
Erythroblasts/cytology , Erythrocyte Count , Hemolysis/physiology , Reticulocyte Count , Specimen Handling/standards , Humans
6.
Int J Lab Hematol ; 34(2): 179-84, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22051137

ABSTRACT

INTRODUCTION: Although there is broad knowledge on the effect of several preanalytical errors on laboratory hematology, there is no information on the reliability of routine hematological testing on hemolyzed specimens. METHODS: K(2) EDTA-anticoagulated blood collected from 13 healthy volunteers was divided in three aliquots. Aliquot A did not undergo further manipulation, while the second and third aliquots (B and C, respectively) were passed 5 and 10 times through a small-gauge needle to produce scalar amounts of hemolysis. Hematological testing was first performed on Advia 2120. The plasma was then separated by centrifugation and tested for lactate dehydrogenase and hemolysis index (HI). RESULTS: As compared with the nonhemolyzed aliquot, analytically and clinically significant variations were recorded in both mildly and frankly hemolyzed specimens for lactate dehydrogenase, HI, red blood cells count, hematocrit, mean corpuscular volume, mean hemoglobin content, lymphocytes, basophils, and large unstained cells. Both the platelets count and the mean platelet volume were also dramatically affected. The other parameters tested (hemoglobin, red blood cell distribution width, neutrophils, and eosinophils) did not vary significantly. CONCLUSION: The results of routine hematological testing on mildly to frankly hemolyzed specimens might be unreliable.


Subject(s)
Hematologic Tests/standards , Hemolysis , Hematologic Tests/methods , Humans , L-Lactate Dehydrogenase/analysis , Reproducibility of Results
10.
Minerva Cardioangiol ; 56(4): 387-90, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18614982

ABSTRACT

AIM: Long QT syndrome is a rare arrhythmic disease with a low incidence in the general population. There are no sure clinical or electrocardiographic parameters that could lead to a correct prognostic stratification in patients affected by this syndrome. The correlation between the incidence of a sudden death or dangerous ventricular arrhythmias and the duration of QTc interval is still a controversial topic. METHODS: Twenty nine children affected by QT long syndrome were admitted to the Division of Pediatric Cardiology of the Casa del Sole Hospital of Palermo (Italy). Their diagnosis was made by electrocardiogram (ECG). The average age of the patients was 7.6 years. The average follow-up was 4 years and three months. A therapy with beta-blocker was administered to all the children. During the follow-up of 4 year and three months, patients were genotyped. Twenty-three out of 29 children had at least one relative affected by the syndrome. Three of them had a familiar dead because of this syndrome and everyone had a duration of maximum QTc higher than the cut off (P=0.0002). All the people who died had not followed the therapy with beta-blocker. Patients with a maximum QTc recorded <500 had not familiar death by this syndrome. RESULTS: Holter and echocardiogram recorded periodically during the observation did not show dangerous arrhythmic events. All children maintained a good health during the follow-up. CONCLUSION: Although conducted on a small study population, the data analysis recorded during this study suggests that in patients affected by QT long syndrome younger than 16 years old undergoing a beta-blocker therapy the prognosis is excellent. The duration of QTc interval appears as a negative prognostic factor, although the beta-blocker therapy has been reduced considerably the incidence of sudden death.


Subject(s)
Long QT Syndrome , Adolescent , Child , Child, Preschool , Follow-Up Studies , Humans , Infant , Long QT Syndrome/genetics , Mutation , Prognosis , Risk Factors
12.
Int J Sports Med ; 29(8): 679-87, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18004690

ABSTRACT

Long-term side effects of high doses of anabolic androgenic steroids self-administration were evaluated in this study. Twenty male bodybuilders, voluntarily starting steroid self-administration, were followed every 6 months over 2 years. Physical examination, haematological, metabolic and endocrine variables, semen analysis, hepatic and prostate ultrasound and echocardiographic evaluations were performed. LH values (baseline 3.43 +/- 1.75) were suppressed at 18 (1.98 +/- 1.99) (p = 0.026) and 24 (2.43 +/- 2.17) (p = 0.026), and FSH (3.95 +/- 2.01) at 6 (3.01 +/- 2.16) (p = 0.031), 12 (2.45 +/- 2.54) (p = 0.029), 18 (2.02 +/- 2.29) (p = 0.032) and 24 (3.42 +/- 2.64) (p = 0.032) months and SHBG (34.11 +/- 10.88) values significantly lowered at 12 (24.81 +/- 12.49) (p < 0.05), 18 (21.28 +/- 11.15) (p < 0.01), 24 months (25.42 +/- 11.16) (p < 0.01). A significant decrease in spermatozoa count (p < 0.01), and fertility index (p = 0.01) occurred. HDL-cholesterol (baseline 56.94 +/- 13.54) was reduced at 18 (41.86 +/- 14.17) (p < 0.01) and 24 (43.82 +/- 18.67) (p < 0.05) months and Apo A-1 at 12 (p < 0.001), 18 (p = 0.05) and 24 (p = 0.05) months. The most important long-term adverse effects were lower fertility and the impairment of lipid profile associated with an increased cardiovascular risk.


Subject(s)
Anabolic Agents/adverse effects , Androgens/adverse effects , Weight Lifting , Adult , Anabolic Agents/administration & dosage , Analysis of Variance , Androgens/administration & dosage , Chi-Square Distribution , Humans , Male , Risk Factors , Self Administration , Statistics, Nonparametric
13.
Int Angiol ; 26(4): 346-52, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18091702

ABSTRACT

AIM: The aim of the present study was to investigate the prevalence of carotid and/or peripheral atherosclerotic lesions in patients with chronic ischemic heart disease (previous acute myocardial infarction [AMI] or stable angina). METHODS: We studied 248 patients (168 male and 80 female), mean age 63+/-10 years, which were investigated for traditional risk factors. Systolic blood pressure, body mass index, lipid profile, fasting glucose and plasma fibrinogen were also measured. We assessed the prevalence of atherosclerotic lesions in carotid and lower limb arteries, by ultrasound duplex scanning (UDS). RESULTS: Angina was present in 33% of the patients, a previous AMI in 67%, a previous transient ischemic attack in 4% and a previous ischemic stroke in 6% of patients. A total of 195 patients underwent coronary angiography: 1 vessel was involved in 48% of patients, 2 vessels in 33%, and 3 vessels in 19%. Detecting peripheral atherosclerotic lesions by UDS, increased intima-media thickness (IMT) or plaques in carotid arteries were found in 232 patients (94%) and carotid stenosis >70% in 13 patients (5%). In lower limb arteries, IMT or plaques were present in 202 patients (82%) and a stenosis >70% in 18 patients (7%). Severity of coronary artery disease (CAD) was correlated to extracoronary atherosclerosis: carotid and lower limb arterial atherosclerosis was detected in 73% of patients with 1 vessel, in 83% of patients with 2 vessel, in 87% of those with 3 vessel CAD. CONCLUSION: Our study suggests that in patients with CAD, it is useful to screen the peripheral circulation by non-invasive tests, such as UDS. Patients with the diagnosis of ischemic heart disease and combined extracoronary atherosclerosis need a careful follow-up and a more aggressive therapy for secondary prevention.


Subject(s)
Atherosclerosis/epidemiology , Carotid Artery Diseases/epidemiology , Myocardial Ischemia/complications , Myocardial Ischemia/pathology , Peripheral Vascular Diseases/epidemiology , Aged , Atherosclerosis/diagnosis , Carotid Artery Diseases/diagnosis , Chronic Disease , Cohort Studies , Female , Humans , Male , Middle Aged , Peripheral Vascular Diseases/diagnosis , Prevalence , Risk Factors , Severity of Illness Index
14.
Pediatr Cardiol ; 23(5): 557-61, 2002.
Article in English | MEDLINE | ID: mdl-12211205

ABSTRACT

Pulsus alternans was observed in a child with left ventricular dysfunction secondary to systemic hypertension. The Echo-Doppler of supravalvular aorta and a simultaneous electrocardiographic trace (ECG) clearly demonstrated the mechanism of an apparent abrupt halving of pulse frequency compared with the ECG, similar to an electromechanical dissociation 2:1. Besides the extreme pulsus alternans, a P wave and a PP cycle length change were also observed. Both mechanical and electrical alternans disappeared with afterload reduction by nitroprusside treatment.


Subject(s)
Pulse , Ventricular Dysfunction, Left/physiopathology , Antihypertensive Agents/therapeutic use , Cardiac Output/physiology , Child , Echocardiography, Doppler , Electrocardiography , Humans , Hypertension/complications , Hypertension/drug therapy , Male , Nitroprusside/therapeutic use , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology
15.
Pediatr Med Chir ; 20(6): 377-80, 1998.
Article in Italian | MEDLINE | ID: mdl-10335535

ABSTRACT

Transposition of great vessels (TGV) is the most frequent neonatal cyanotic malformative cardiopathy. The Authors report their experience in surgical anatomical correction of transposition of the great arteries in 55 patients, 44 male and 11 female. Minimum age was 2 days, maximum 6 months. TGV was simple in 38 cases and associated with ventricular defect in 12 cases, with double outlet right ventricle in 3 cases, and with complex cardiopathy in 2 cases. There have been 11 deaths. The cause of death was: cardiac failure in 3 patients, myocardial infarct in 4 patients, respiratory insufficiency in 2 patients, and sepsis in 2 patients. There was one death by myocardial infarction and 1 asymptomatic ostial left coronary stenosis during follow-up (from 1 to 104 months). There were neither anastomotic pulmonary stenosis nor aortic valve incompetence. The authors review the literature on functional and anatomic correction of TGV and underline the importance of precocious anatomic together with early diagnosis, percutaneous atrioseptostomy and pharmacologic (PGE1) therapy in determining further reduction of mortality and to improve late outcome.


Subject(s)
Transposition of Great Vessels/surgery , Age Factors , Double Outlet Right Ventricle/complications , Extracorporeal Circulation , Female , Follow-Up Studies , Heart Septal Defects, Ventricular/complications , Humans , Infant , Infant, Newborn , Male , Time Factors , Transposition of Great Vessels/complications , Transposition of Great Vessels/physiopathology
16.
G Ital Cardiol ; 26(12): 1425-30, 1996 Dec.
Article in Italian | MEDLINE | ID: mdl-9162671

ABSTRACT

A modified technique for pulmonary valvuloplasty is described in a 1-day-old newborn with near pulmonary atresia. A transumbilical venous approach and a complete set of devices for coronary angioplasty were utilized; the principal technical innovation was the use of a 7 French right coronary artery guiding catheter. This allowed a firm support to advance the first balloon catheter (a 3.5 coronary angioplasty catheter) through the pulmonary valve, maintaining the guidewire in a stable position in the descending aorta. The dilation was easily completed with progressively larger balloons. The total procedure time was 82' (fluroscopy time 20'), significantly shorter than the previous personal experience and the data from the literature.


Subject(s)
Catheterization/methods , Pulmonary Valve/abnormalities , Catheterization/instrumentation , Constriction, Pathologic/therapy , Female , Heart Valve Diseases/therapy , Humans , Infant, Newborn , Pulmonary Atresia/therapy , Recurrence
18.
G Ital Cardiol ; 22(10): 1225-32, 1992 Oct.
Article in Italian | MEDLINE | ID: mdl-1291417

ABSTRACT

Homozygous familial hypercholesterolaemia is characterized by cutaneous xanthoma development from infancy, precocious and accelerated atherosclerosis with clinical signs of ischemic heart disease and frequent involvement of left heart valves resulting in stenosis and/or incompetence. Two cases are described of this condition, both associated with aortic stenosis. In one case mitral incompetence and thromboembolic pulmonary hypertension were also found. The mitral valve is involved in the atherosclerotic process at the level of the cusps. These become thickened and stiff. Aortic stenosis is mainly due to atheromas infiltrating the Valsalva sinuses and the ascending aorta. Pulmonary hypertension, never reported before in this disease, is probably due to concomitant atheromatosis involving the pulmonary artery with secondary fatty embolism.


Subject(s)
Aortic Valve Stenosis/etiology , Hyperlipoproteinemia Type II/complications , Aortic Valve Stenosis/diagnostic imaging , Bacteroides Infections/complications , Bacteroides fragilis , Child , Coronary Disease/etiology , Electrocardiography , Female , Homozygote , Humans , Hyperlipoproteinemia Type II/diagnostic imaging , Hypertension, Pulmonary/etiology , Ultrasonography
19.
G Ital Cardiol ; 22(7): 869-74, 1992 Jul.
Article in Italian | MEDLINE | ID: mdl-1473663

ABSTRACT

The Kawasaki disease (mucocutaneous lymph node syndrome) usually affects children younger than 5 years, and is considered one of the most important causes of myocardial infarction in children. Some disagreement still exists regarding the following: the selection, surgery techniques, and follow-up outcomes of aortocoronary bypass grafting in Kawasaki disease. We describe the case of a three-year-old child with Kawasaki disease and with left and right multiple aneurysms, suffering from an antero-lateral myocardial infarction and inferior reinfarction. After thrombolytic treatment and coronary arteriography, left anterior descending aortocoronary bypass grafting was performed by using the autologous saphenous vein. After two years clinical, angiographic, ergometric and echocardiographic examinations show good surgical results with a global and regional kinesis improvement.


Subject(s)
Coronary Artery Bypass , Mucocutaneous Lymph Node Syndrome/surgery , Child, Preschool , Combined Modality Therapy , Coronary Aneurysm/diagnosis , Coronary Aneurysm/epidemiology , Coronary Aneurysm/etiology , Coronary Aneurysm/surgery , Coronary Artery Bypass/statistics & numerical data , Follow-Up Studies , Humans , Male , Mucocutaneous Lymph Node Syndrome/complications , Mucocutaneous Lymph Node Syndrome/diagnosis , Mucocutaneous Lymph Node Syndrome/epidemiology , Myocardial Infarction/diagnosis , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Myocardial Infarction/surgery , Recurrence , Thrombolytic Therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...