Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Chem Pharm Bull (Tokyo) ; 54(4): 442-7, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16595942

ABSTRACT

A method for sample preparation and analysis by high-performance liquid chromatography with UV detection (HPLC-UV) was developed for analysis of psoralen, bergapten and 5-[3-(4,5-dihydro-5,5-dimethyl-4-oxo-2-furanyl)-butoxy]-7H-furo[3-2-g][1]benzopyran-7-one in capsules and tablets employed in Brazil for certain illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Analytical curves for furanocoumarins were linear in the range of 1.0-50.0 microg/ml. The recoveries of the furanocoumarins in the products analyzed were 97.3-99.5%, and the percent coefficient of variation for the quantitative analysis of the furanocoumarins in the analyses was under 5%. For inter-equipment study gas chromatography (GC) was employed.


Subject(s)
Benzopyrans/analysis , Ficusin/analysis , Furocoumarins/analysis , Methoxsalen/analogs & derivatives , Photosensitizing Agents/analysis , 5-Methoxypsoralen , Capsules/chemistry , Chromatography, High Pressure Liquid , Methoxsalen/analysis , Plant Preparations/analysis , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet , Tablets/chemistry
2.
J Pharm Biomed Anal ; 36(2): 415-20, 2004 Oct 29.
Article in English | MEDLINE | ID: mdl-15496338

ABSTRACT

A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.


Subject(s)
Furocoumarins/analysis , Methoxsalen/analogs & derivatives , Photosensitizing Agents/analysis , Plants, Medicinal/chemistry , 5-Methoxypsoralen , Calibration , Chromatography, High Pressure Liquid , Drug Stability , Flame Ionization , Methoxsalen/analysis , Pharmaceutical Solutions , Reproducibility of Results , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...