Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
3.
Pulm Ther ; 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38937418

ABSTRACT

Regardless of the type, extracorporeal membrane oxygenation (ECMO) requires the use of large intravascular cannulas and results in multiple abnormalities including non-physiologic blood flow, hemodynamic perturbation, rapid changes in blood oxygen and carbon dioxide levels, coagulation abnormalities, and a significant systemic inflammatory response. Among other sequelae, neurologic complications are an important source of mortality and long-term morbidity. The frequency of neurologic complications varies and is likely underreported due to the high mortality rate. Neurologic complications in patients supported by ECMO include ischemic and hemorrhagic stroke, hypoxic brain injury, intracranial hemorrhage, and brain death. In addition to the disease process that necessitates ECMO, cannulation strategies and physiologic disturbances influence neurologic outcomes in this high-risk population. For example, the overall documented rate of neurologic complications in the venovenous ECMO population is lower, but a higher rate of intracranial hemorrhage exists. Meanwhile, in the venoarterial ECMO population, ischemia and global hypoperfusion seem to compose a higher percentage of neurologic complications. In what follows, the literature is reviewed to discuss the pathophysiology, incidence, risk factors, and outcomes related to short-term neurologic complications in patients supported by ECMO.

4.
J Cardiothorac Vasc Anesth ; 38(6): 1378-1389, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38490900

ABSTRACT

Refractory vasodilatory shock, or vasoplegia, is a pathophysiologic state observed in the intensive care unit and operating room in patients with a variety of primary diagnoses. Definitions of vasoplegia vary by source but are qualitatively defined clinically as a normal or high cardiac index and low systemic vascular resistance causing hypotension despite high-dose vasopressors in the setting of euvolemia. This definition can be difficult to apply to patients undergoing mechanical circulatory support (MCS). A large body of mostly retrospective literature exists on vasoplegia in the non-MCS population, but the increased use of temporary MCS justifies an examination of vasoplegia in this population. MCS, particularly extracorporeal membrane oxygenation, adds complexity to the diagnosis and management of vasoplegia due to challenges in determining cardiac output (or total blood flow), lack of clarity on appropriate dosing of noncatecholamine interventions, increased thrombosis risk, the difficulty in determining the endpoints of adequate volume resuscitation, and the unclear effects of rescue agents (methylene blue, hydroxocobalamin, and angiotensin II) on MCS device monitoring and function. Care teams must combine data from invasive and noninvasive sources to diagnose vasoplegia in this population. In this narrative review, the available literature is surveyed to provide guidance on the diagnosis and management of vasoplegia in the temporary MCS population, with a focus on noncatecholamine treatments and special considerations for patients supported by extracorporeal membrane oxygenation, transvalvular heart pumps, and other ventricular assist devices.


Subject(s)
Extracorporeal Membrane Oxygenation , Vasoplegia , Humans , Vasoplegia/diagnosis , Vasoplegia/therapy , Vasoplegia/etiology , Extracorporeal Membrane Oxygenation/methods , Disease Management , Heart-Assist Devices
6.
J Blood Med ; 13: 363-372, 2022.
Article in English | MEDLINE | ID: mdl-35789896

ABSTRACT

Background: The aim of this study was to assess changes in hemostasis and associated outcome of hospitalized patients with COVID-19 infection and mild hypoxemia. Methods: Adult patients with COVID-19 infection and hypoxemia admitted to ICU were included in this prospective observational study. The primary outcome was defined as an unfavorable course of the disease if a patient: (1) developed a thromboembolic event while receiving anticoagulation prophylaxis, (2) had prolonged ICU stay, or (3) died. Demographic data, laboratory parameters and thromboelastometry (ROTEM) test results were collected. Results: Twenty-five patients were recruited into the study. There were 16 patients with an unfavorable course of the disease. Compared to the 9 patients in the favorable course group, patients with an unfavorable course had a lower platelet count, median difference of 154 (95% CI, 26 to 223 x109/L), P = 0.012, and lower clot firmness parameters in EXTEM assay: amplitude at 20 minutes (A20), median difference of 7 (95% CI, 2 to 11) P = 0.006, maximum clot firmness (MCF), median difference of 6 (95% CI, 3 to 10) P = 0.006 and area under the curve (AUC) with a median difference of 671 (95% CI, 244 to 1029) P = 0.005. They also demonstrated suppression of fibrinolysis: higher lysis index 60, median difference of -3 (95% CI, -6 to 0), P = 0.023. Results of functional fibrinogen (FIBTEM) assay were similar between the groups. Conclusion: The platelet count and the results of EXTEM assay, but not FIBTEM assay, were associated with the difference in clinical outcome among patients with COVID-19 infection and hypoxemia. The role of platelets in the outcome of COVID-19 infection calls for further investigation. Future studies on adjusting anticoagulant therapy based on the results of viscoelastic testing may be beneficial.

7.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3318-3326, 2022 08.
Article in English | MEDLINE | ID: mdl-35545462

ABSTRACT

Mechanical circulatory support (MCS) is used in cardiogenic shock for periprocedural hemodynamic stability in high-risk patients and to support patients with symptomatic coronary artery disease. Depending on the MCS type, oxygenation and ventilation, in addition to increasing blood pressure by augmenting blood flow, can be achieved. MCS typically follows a failure of less invasive maneuvers or intolerance to them, such as significant ventricular arrhythmia burden from inotropic support. MCS options include intra-aortic balloon pump, transvalvular percutaneous left ventricular assist devices, venoarterial extracorporeal membrane oxygenation, and surgically implanted left ventricular assist devices. The number of MCS options has increased, and this has made the decision-making process complicated. MCS decision-making is complex, even in patients without valvular pathology. The presence of aortic valve (AV) abnormalities, such as aortic stenosis, aortic insufficiency, replaced AVs, or AV masses, adds even further to the challenge of selecting the appropriate support strategy. In this narrative review, a concise review of MCS options and the special considerations for various AV pathologies are presented.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Aortic Valve/surgery , Extracorporeal Membrane Oxygenation/adverse effects , Heart-Assist Devices/adverse effects , Humans , Intra-Aortic Balloon Pumping/adverse effects , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery
9.
Article in English | MEDLINE | ID: mdl-34790885

ABSTRACT

Disability is an important and often overlooked component of diversity. Individuals with disabilities bring a rare perspective to science, technology, engineering, mathematics, and medicine (STEMM) because of their unique experiences approaching complex issues related to health and disability, navigating the healthcare system, creatively solving problems unfamiliar to many individuals without disabilities, managing time and resources that are limited by physical or mental constraints, and advocating for themselves and others in the disabled community. Yet, individuals with disabilities are underrepresented in STEMM. Professional organizations can address this underrepresentation by recruiting individuals with disabilities for leadership opportunities, easing financial burdens, providing equal access, fostering peer-mentor groups, and establishing a culture of equity and inclusion spanning all facets of diversity. We are a group of deaf and hard-of-hearing (D/HH) engineers, scientists, and clinicians, most of whom are active in clinical practice and/or auditory research. We have worked within our professional societies to improve access and inclusion for D/HH individuals and others with disabilities. We describe how different models of disability inform our understanding of disability as a form of diversity. We address heterogeneity within disabled communities, including intersectionality between disability and other forms of diversity. We highlight how the Association for Research in Otolaryngology has supported our efforts to reduce ableism and promote access and inclusion for D/HH individuals. We also discuss future directions and challenges. The tools and approaches discussed here can be applied by other professional organizations to include individuals with all forms of diversity in STEMM.

10.
13.
J Clin Anesth ; 51: 108-117, 2018 12.
Article in English | MEDLINE | ID: mdl-30103101

ABSTRACT

STUDY OBJECTIVE: To review research highlights of manuscripts published in 2017 that pertain to all aspects of the clinical practice of anesthesiology. DESIGN: Narrative review. SETTING: N/A. MATERIALS: The major themes addressed in this review include recent studies examining airway management, obstetrical and gynecological anesthesia, pediatric anesthesia, cardiac anesthesia, regional analgesia and pain management. INTERVENTIONS: N/A. MAIN RESULTS: N/A. CONCLUSIONS: This review will highlight and inform anesthesiologists of the developing trends in clinical anesthesia and will also pose new challenges for further studies.


Subject(s)
Airway Management/trends , Anesthesia/trends , Anesthesiology/trends , Pain Management/trends , Airway Management/instrumentation , Airway Management/methods , Anesthesia/methods , Anesthesiology/instrumentation , Anesthesiology/methods , Humans , Pain Management/methods , Pain, Postoperative/etiology , Pain, Postoperative/therapy , Surgical Procedures, Operative/adverse effects
16.
Front Psychiatry ; 5: 94, 2014.
Article in English | MEDLINE | ID: mdl-25132825

ABSTRACT

Differences in cortical thickness in the lateral temporal lobe, including the planum temporale (PT), have been reported in MRI studies of schizophrenia (SCZ) and bipolar disorder (BPD) patients. Most of these studies have used a single-valued global or local measure for thickness. However, additional and complementary information can be obtained by generating labeled cortical distance maps (LCDMs), which are distances of labeled gray matter (GM) voxels from the nearest point on the GM/white matter (WM) (inner) cortical surface. Statistical analyses of pooled and censored LCDM distances reveal subtle differences in PT between SCZ and BPD groups from data generated by Ratnanather et al. (Schizophrenia Research, http://dx.doi.org/10.1016/j.schres.2013.08.014). These results confirm that the left planum temporale (LPT) is more sensitive than the right PT in distinguishing between SCZ, BPD, and healthy controls. Also confirmed is a strong gender effect, with a thicker PT seen in males than in females. The differences between groups at smaller distances in the LPT revealed by pooled and censored LCDM analysis suggest that SCZ and BPD have different effects on the cortical mantle close to the GM/WM surface. This is consistent with reported subtle changes in the cortical mantle observed in post-mortem studies.

17.
Hear Res ; 314: 33-41, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24882641

ABSTRACT

A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal turn. In the present study we report on the development of a new method to assist CI electrode insertion. The design objectives are (1) an automated and standardized insertion technique across patients with (2) more apical insertion than is possible by the contemporary methods, while (3) minimizing insertion trauma. The method relies on a viscous fluid flow through the cochlea to carry the electrode array with it. A small cochleostomy (∼100-150 um in diameter) is made in scala vestibuli (SV) and the round window (RW) membrane is opened. A flow of diluted Sodium Hyaluronate (also known as Hyaluronic Acid, (HA)) is set up from the RW to the SV opening using a perfusion pump that sets up a unidirectional flow. Once the flow is established an implant is dropped into the ongoing flow. Here we present a proof-of-concept study where we used this technique to insert silicone implants all the way to the cochlear apex in rats and gerbils. In light-microscopic histology, the implantation occurred without cochlear trauma. To further assess the ototoxicity of the HA perfusion, we measured compound action potential (CAP) thresholds following the perfusion of HA, and found that the CAP thresholds were substantially elevated. Thus, at this point the method is promising, and requires further development to become clinically viable.


Subject(s)
Cochlea/pathology , Cochlear Implantation/methods , Cochlear Implants , Electrodes, Implanted , Action Potentials , Animals , Basilar Membrane/pathology , Electrodes , Gerbillinae , Hearing , Humans , Hyaluronic Acid/chemistry , Perfusion , Rats , Round Window, Ear/surgery , Temporal Bone/surgery
18.
Schizophr Res ; 150(2-3): 476-83, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24012458

ABSTRACT

Structural abnormalities in temporal lobe, including the superior temporal gyrus (STG) and planum temporale (PT), have been reported in schizophrenia (SCZ) and bipolar disorder (BPD) patients. While most MRI studies have suggested gray matter volume and surface area reduction in temporal lobe regions, few have explored changes in laminar thickness in PT and STG in SCZ and BPD. ROI subvolumes of the STG from 94 subjects were used to yield gray matter volume, gray/white surface area and laminar thickness for STG and PT cortical regions. Morphometric analysis suggests that there may be gender and laterality effects on the size and shape of the PT in BPD (n=36) and SCZ (n=31) with reduced laterality in PT in subjects with SCZ but not in BPD. In addition, PT surface area was seen to be larger in males, and asymmetry in PT surface area was larger in BPD. Subjects with SCZ had reduced thickness and smaller asymmetry in PT volume. Thus, the PT probably plays a more sensitive role than the STG in structural abnormalities seen in SCZ.


Subject(s)
Bipolar Disorder/pathology , Schizophrenia/pathology , Temporal Lobe/pathology , Adult , Analysis of Variance , Brain Mapping , Female , Functional Laterality , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male , Middle Aged , Sex Factors
19.
Audiol Neurootol ; 17(5): 338-48, 2012.
Article in English | MEDLINE | ID: mdl-22814034

ABSTRACT

Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability are not fully understood. Simultaneous measurements of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) enable quantification of the differential pressure across the cochlear partition, the stimulus that excites the cochlear partition. We used intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Sound-induced pressures in SV and ST, as well as stapes velocity and ear canal pressure were measured simultaneously for various sizes of SCD followed by SCD patching. Our results showed that at low frequencies (<600 Hz), SCD decreased the pressure in both SV and ST, as well as differential pressure, and these effects became more pronounced as dehiscence size was increased. Near 100 Hz, SV decreased by about 10 dB for a 0.5-mm dehiscence and by 20 dB for a 2-mm dehiscence, while ST decreased by about 8 dB for a 0.5-mm dehiscence and by 18 dB for a 2-mm dehiscence. Differential pressure decreased by about 10 dB for a 0.5-mm dehiscence and by about 20 dB for a 2-mm dehiscence at 100 Hz. In some ears, for frequencies above 1 kHz, the smallest pinpoint dehiscence had bigger effects on the differential pressure (10-dB decrease) than larger dehiscences (less than 10-dB decrease), suggesting larger hearing losses in this frequency range. These effects due to SCD were reversible by patching the dehiscence. We also showed that under certain circumstances such as SCD, stapes velocity is not related to how the ear can transduce sound across the cochlear partition because it is not directly related to the differential pressure, emphasizing that certain pathologies cannot be fully assessed by measurements such as stapes velocity.


Subject(s)
Hearing Loss/physiopathology , Semicircular Canals/pathology , Cadaver , Humans , Pressure , Sound , Stapes/physiopathology
20.
Ear Hear ; 33(1): 35-43, 2012.
Article in English | MEDLINE | ID: mdl-21857516

ABSTRACT

OBJECTIVE: The goal of the present study was to investigate the clinical utility of measurements of ear-canal reflectance (ECR) in a population of patients with conductive hearing loss in the presence of an intact, healthy tympanic membrane and an aerated middle ear. We also sought to compare the diagnostic accuracy of umbo velocity (VU) measurements and measurements of ECR in the same group of patients. DESIGN: This prospective study comprised 31 adult patients with conductive hearing loss, of which 14 had surgically confirmed stapes fixation due to otosclerosis, 6 had surgically confirmed ossicular discontinuity, and 11 had computed tomography and vestibular evoked myogenic potential confirmed superior semicircular canal dehiscence (SCD). Measurements on all 31 ears included pure-tone audiometry for 0.25 to 8 kHz, ECR for 0.2 to 6 kHz using the Mimosa Acoustics HearID system, and VU for 0.3 to 6 kHz using the HLV-1000 laser Doppler vibrometer (Polytec Inc, Waldbronn, Germany). We analyzed power reflectance |ECR| as well as the absorbance level = 10 × log10(1 - |ECR|). All measurements were made before any surgical intervention. The VU and ECR data were plotted against normative data obtained in a companion study of 58 strictly defined normal ears (). RESULTS: Small increases in |ECR| at low-to-mid frequencies (400-1000 Hz) were observed in cases with stapes fixation, while narrowband decreases were seen for both SCD and ossicular discontinuity. The SCD and ossicular discontinuity differed in that the SCD had smaller decreases at mid-frequency (∼1000 Hz), whereas ossicular discontinuity had larger decreases at lower frequencies (500-800 Hz). SCD tended to have less air-bone gap at high frequencies (1-4 kHz) compared with stapes fixation and ossicular discontinuity. The |ECR| measurements, in conjunction with audiometry, could successfully separate 28 of the 31 cases into the three pathologies. By comparison, VU measurements, in conjunction with audiometry, could successfully separate various pathologies in 29 of 31 cases. CONCLUSIONS: The combination of |ECR| with audiometry showed clinical utility in the differential diagnosis of conductive hearing loss in the presence of an intact tympanic membrane and an aerated middle ear and seems to be of similar sensitivity and specificity to measurements of VU plus audiometry. Additional research is needed to expand upon these promising preliminary results.


Subject(s)
Acoustic Impedance Tests/methods , Acoustic Impedance Tests/standards , Ear Canal/physiology , Hearing Loss, Conductive/diagnosis , Tympanic Membrane/physiology , Adult , Aged , Audiometry, Pure-Tone , Female , Hearing Loss, Conductive/pathology , Hearing Loss, Conductive/surgery , Humans , Male , Middle Aged , Pilot Projects , Preoperative Care , Prospective Studies , Reproducibility of Results , Semicircular Canals/pathology , Sensitivity and Specificity , Stapes Mobilization , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...