Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
J Breath Res ; 18(1)2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38096565

ABSTRACT

Due to the overall low abundance of volatile compounds in exhaled breath, it is necessary to preconcentrate the sample prior to traditional thermal desorption (TD) gas chromatography mass spectrometry analysis. While certain aspects of TD tubes, such as volatile storage, have been evaluated, many aspects remain uncharacterized. Two common TD tubes, Tenax TA and Biomonitoring 5TD tubes, were evaluated for background content and flow rate variability. The data illustrate that the Biomonitoring 5TD tubes have the highest number (23) and abundance of background contamination greater than 3x the mean noise when compared to Tenax TA (13) and empty tubes (9). Tentative identifications of the compounds in the background contamination experiment show that greater than 59% (16/27) of the compounds identified have been reported in the breath literature. The data illustrate the TD tube background abundance could account for more than 70% of the chromatographic signal from exhaled breath for these select compounds. Flow rate measurements of 200 Tenax TA and 200 Biomonitoring 5TD tubes show a large range in measured flow rates among the TD tubes (Tenax: 252.9-284.0 ml min-1, 5TD: 220.6-255.1 ml min-1). Finally, TD tubes of each type, Tenax TA and Biomonitoring 5TD, previously established to have high, medium, and low flow rates, show insignificant differences (p> 0.05) among the tubes of different flow rates, using both gas standards and an exhaled breath from a peppermint experiment. Collectively, these results establish overall background compounds attributed to each TD tube type tested. Additionally, while measured flow rate variability is present and plausibly impacts exhaled breath results, the data demonstrate no statistically significant difference was observed between tubes showing high, medium, and low flow rates from two separate sample types.


Subject(s)
Volatile Organic Compounds , Humans , Volatile Organic Compounds/analysis , Breath Tests/methods , Exhalation , Gas Chromatography-Mass Spectrometry/methods , Reference Standards
2.
Life Sci Alliance ; 6(11)2023 11.
Article in English | MEDLINE | ID: mdl-37666666

ABSTRACT

Ras proteins are membrane-bound GTPases that regulate essential cellular processes at the plasma membrane (PM). Constitutively active mutations of K-Ras, one of the three Ras isoforms in mammalian cells, are frequently found in human cancers. Ferrocene derivatives, which elevate cellular reactive oxygen species (ROS), have shown to block the growth of non-small cell lung cancers harboring oncogenic mutant K-Ras. Here, we tested a novel ferrocene derivative on the growth of pancreatic ductal adenocarcinoma and non-small cell lung cancer. Our compound, which elevated cellular ROS levels, inhibited the growth of K-Ras-driven cancers, and abrogated the PM binding and signaling of K-Ras in an isoform-specific manner. These effects were reversed upon antioxidant supplementation, suggesting a ROS-mediated mechanism. We further identified that K-Ras His95 residue plays an important role in this process, and it is putatively oxidized by cellular ROS. Together, our study demonstrates that the redox system directly regulates K-Ras/PM binding and signaling via oxidative modification at the His95, and proposes a role of oncogenic mutant K-Ras in the recently described antioxidant-induced growth and metastasis of K-Ras-driven cancers.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Pancreatic Neoplasms , Humans , Animals , Antioxidants , Metallocenes/pharmacology , Reactive Oxygen Species , Oxidation-Reduction , Oxidative Stress , Mammals
3.
J Breath Res ; 17(3)2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37352843

ABSTRACT

Exhaled breath research has been hindered by a lack of standardization in collection and analysis methodologies. Recently, the Respiration Collector forIn VitroAnalysis (ReCIVA) sampling device has illustrated the potential to provide a consistent and convenient method for exhaled breath collection onto adsorbent media. However, the significant costs, compared to exhaled breath bags, associated with the standardized collector is believed to be the reason for limited widespread use by researchers in the exhaled breath field. For example, in addition to the sampling hardware, a single-use disposable silicon mask affixed with a filter is required for each exhaled breath collection. To reduce the financial burden, streamline device upkeep, reduce waste material, and ease the logistical burden associated with the single use masks, it is hypothesized that the consumable masks and filters could be sterilized by autoclaving for reuse. The masks were contaminated, autoclaved, and then tested for any surviving pathogens with spore strip standards and by measuring the optical density of cultures. The compound background collected when using the ReCIVA with new masks was compared to that collected with repeatedly autoclaved masks via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The capacity to block particulate matter of new filters was tested against that of autoclaved filters by introducing an aerosol and comparing pre-filter and post-filter particle counts. Finally, breath samplings were conducted with new masks and autoclaved masks to test for changes in measurements by TD-GC-MS of exogenous and endogenous compounds. The data illustrate the autoclave cycle sterilizes masks spiked with saliva to background levels (p= 0.2527). The results indicate that background levels of siloxane compounds are increased as masks are repetitively autoclaved. The data show that mask filters have significant breakthrough of 1µm particles after five repetitive autoclaving cycles compared to new filters (p= 0.0219). Finally, exhaled breath results utilizing a peppermint ingestion protocol indicate two compounds associated with peppermint, menthone and 1-Methyl-4-(1-methylethyl)-cyclohexanol, and an endogenous exhaled breath compound, isoprene, show no significant difference if sampled with a new mask or a mask autoclaved five times (p> 0.1063). Collectively, the data indicate that ReCIVA masks and filters can be sterilized via autoclave and reused. The results suggest ReCIVA mask and filter reuse should be limited to three times to limit potentially problematic background contaminants and filter dysfunction.


Subject(s)
Breath Tests , Sterilization , Humans , Breath Tests/methods , Gas Chromatography-Mass Spectrometry , Exhalation , Reference Standards
4.
J Breath Res ; 17(2)2023 01 20.
Article in English | MEDLINE | ID: mdl-36596256

ABSTRACT

Isoprene is one of the most abundant and most frequently evaluated volatile organic compounds in exhaled breath. Recently, several individuals with background levels of exhaled isoprene have been identified. Here, case study data are provided for an individual, identified from a previous study, with this low prevalence phenotype. It is hypothesized that the individual will illustrate low levels of exhaled isoprene at rest and during exercise. At rest, the subject (7.1 ppb) shows background (µ= 14.2 ± 7.0 ppb) levels of exhaled isoprene while the control group illustrates significantly higher quantities (µ= 266.2 ± 72.3 ppb) via proton transfer reaction mass spectrometry (PTR-MS). The result, background levels of isoprene at rest, is verified by thermal desorption gas chromatography mass spectrometry (TD-GC-MS) collections with the individual showing -3.6 ppb exhaled isoprene while the room background containedµ= -4.1 ± 0.1 ppb isoprene. As isoprene has been shown previously to increase at the initiation of exercise, exercise bike experiments were performed with the individual identified with low isoprene, yielding low and invariant levels of exhaled isoprene (µ= 6.6 ± 0.1 ppb) during the exercise while control subjects illustrated an approximate 2.5-fold increase (preµ= 286.3 ± 43.8 ppb, exerciseµ= 573.0 ± 147.8 ppb) in exhaled isoprene upon exercise start. Additionally, exhaled breath bag data showed a significant decrease in isoprene (delta post/pre, p = 0.0078) of the control group following the exercise regimen. Finally, TD-GC-MS results for exhaled isoprene from the individual's family (mother, father, sister and maternal grandmother) illustrated that the mother and father exhibited isoprene values (28.5 ppb, 77.2 ppb) below control samples 95% confidence interval (µ= 166.8 ± 43.3 ppb) while the individual's sister (182.0 ppb) was within the control range. These data provide evidence for a large dynamic range in exhaled isoprene in this family. Collectively, these results provide additional data surrounding the existence of a small population of individuals with background levels of exhaled isoprene.


Subject(s)
Breath Tests , Butadienes , Breath Tests/methods , Mass Spectrometry/methods , Gas Chromatography-Mass Spectrometry/methods , Butadienes/analysis , Hemiterpenes/analysis , Exhalation
5.
ACS Sens ; 8(2): 610-618, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36657059

ABSTRACT

Inhaled medications are commonplace for administering bronchodilators, anticholinergics, and corticosteroids. While they have a defined legitimate use, they are also used in sporting events as performance-enhancing drugs. These performance enhancers can be acquired via both legal (i.e., at a pharmacy through over-the-counter medications or through a prescription) and illicit (i.e., black market and foreign pharmacies) means, thus making monitoring procurement impossible. While urine tests can detect these pharmacological agents hours after they have been inhaled, there is a significant lag time before they are observed in urine. Direct detection of these inhaled agents is complicated and requires a multiplexed approach due to the sheer number of inhaled pharmacological agents. Therefore, detection of propellants, which carry the drug into the lungs, provides a simpler path forward toward detection of broad pharmacological agents. In this paper, we demonstrate the first use of terahertz spectroscopy (THz) to detect inhaled medications in human subjects. Notably, we were able to detect and quantitate the propellant, HFA-134a, in breath up to 30 min after using an asthma inhaler, enabling the use of a point-of-care device to monitor exhaled breath for the presence of propellants. We also demonstrate via simulations that the same approach can be leveraged to detect and identify next-generation propellants, specifically HFA-152a. As a result, we provide evidence that a single point-of-care THz sensor can detect when individuals have used pressure-mediated dose inhalers (pMDIs) without further modification of the hardware.


Subject(s)
Asthma , Terahertz Spectroscopy , Humans , Aerosol Propellants/therapeutic use , Asthma/drug therapy , Nebulizers and Vaporizers , Bronchodilator Agents/chemistry , Bronchodilator Agents/therapeutic use
6.
Front Chem ; 9: 659583, 2021.
Article in English | MEDLINE | ID: mdl-34026725

ABSTRACT

Sweat is emerging as a prominent biosource for real-time human performance monitoring applications. Although promising, sources of variability must be identified to truly utilize sweat for biomarker applications. In this proof-of-concept study, a targeted metabolomics method was applied to sweat collected from the forearms of participants in a 12-week exercise program who ingested either low or high nutritional supplementation twice daily. The data establish the use of dried powder mass as a method for metabolomic data normalization from sweat samples. Additionally, the results support the hypothesis that ingestion of regular nutritional supplementation semi-quantitatively impact the sweat metabolome. For example, a receiver operating characteristic (ROC) curve of relative normalized metabolite quantities show an area under the curve of 0.82 suggesting the sweat metabolome can moderately predict if an individual is taking nutritional supplementation. Finally, a significant correlation between physical performance and the sweat metabolome are established. For instance, the data illustrate that by utilizing multiple linear regression modeling approaches, sweat metabolite quantities can predict VO2 max (p = 0.0346), peak lower body Windage (p = 0.0112), and abdominal circumference (p = 0.0425). The results illustrate the need to account for dietary nutrition in biomarker discovery applications involving sweat as a biosource.

7.
Talanta ; 223(Pt 1): 121797, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33303130

ABSTRACT

As the demand for real-time exercise performance feedback increases, excreted sweat has become a biosource of interest for continuous human performance assessment. For sweat to truly fulfill this requirement, analyte concentrations must be normalized to adequately assess day-to-day differences within and among individuals. In this manuscript, data are presented highlighting the use of accurate localized sweat rate as a means for ion and global metabolomic data normalization. The results illustrate large sweat rate variability among individuals over the course of two distinct exercises protocols. Furthermore, the data show sweat rate is not symmetrical at similar locations among right and left forearms of individuals (p = 0.0007). Sweat ion conductivity analysis suggest overall sweat rate normalization reduces variability collectively among ion values and participants with principal component analysis showing 77.8% of variation in the data set attributable to sweat rate normalization. Global metabolomic analysis of sweat illustrated overall rate normalization increases the variability among test subjects with 72.7% of the variation explained by sweat rate normalization. Finally, overall rate normalized metabolomic features of sweat significantly correlated (ρ ≥ 0.7, ρ ≤ -0.7) with measured performance metrics of the individual, establishing the potential for sweat to be used as a biosource for performance monitoring. Collectively, these data illustrate the importance of accurate localized sweat rate determination, for analyte data normalization, in support for the use of sweat in biomarker discovery efforts to predict human performance.


Subject(s)
Metabolomics , Sweat , Biomarkers , Exercise , Humans , Principal Component Analysis
8.
J Breath Res ; 14(3): 036004, 2020 05 27.
Article in English | MEDLINE | ID: mdl-32155613

ABSTRACT

The Respiration Collector for In Vitro Analysis (ReCIVA) sampler, marketed by Owlstone Medical, provides a step forward in exhaled breath sampling through active sampling directly onto thermal desorption (TD) tubes. Although an improvement to the issues surrounding breath bag sampling, the ReCIVA device, first released in 2015, is a relatively new research and clinical tool that requires further exploration. Here, data are presented comparing two distinct ReCIVA devices. The results, comparing ReCIVA serial numbers #33 and #65, demonstrate that overall statistically insignificant results are obtained via targeted isoprene quantitation (p > 0.05). However, when the data are parsed by the TD tube type used to capture breath volatiles, either Tenax TA or the dual bed Tenax/Carbograph 5TD (5TD), a statistical difference (p < 0.05) among the two different TD tubes was present. These data, comparing the two ReCIVA devices with both Tenax TA and 5TD tubes, are further supported by a global metabolomics analysis yielding 85% of z-scores, comparing ReCIVA devices, below the limit for significance. Experiments to determine the effect of breathing rate on ReCIVA function, using guided breathing for low (7.5 breaths min-1) and high (15 breaths min-1) breathing rates, demonstrate the ReCIVA device shows no statistical difference among breathing rates for quantitated isoprene (p > 0.05). Global metabolomics analysis of the guided breathing rate data shows more than 87% of the z-scores, comparing high and low breathing rates using both the Tenax and the 5TD tubes, are below the level for significance. Finally, data are provided from a single participant who displayed background levels of isoprene while illustrating levels of acetone consistent with the remaining participants. Collectively, these data support the use of multiple ReCIVA devices for exhaled breath collection and provide evidence for an instance where exhaled isoprene is consistent with background levels.


Subject(s)
Breath Tests/instrumentation , Specimen Handling/instrumentation , Temperature , Butadienes/analysis , Exhalation , Hemiterpenes/analysis , Humans , Male , Reference Standards , Volatile Organic Compounds/analysis
9.
J Breath Res ; 14(1): 016009, 2019 12 16.
Article in English | MEDLINE | ID: mdl-31703231

ABSTRACT

Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.


Subject(s)
Breath Tests/methods , Butadienes/analysis , Calibration , Exhalation , Hemiterpenes/analysis , Humans , Male , Reference Standards , Siloxanes/chemistry , Specimen Handling
10.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1126-1127: 121763, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31430684

ABSTRACT

Due to increased interest in the use of excreted sweat for biomarker discovery, data must be generated supporting sample collection and handling methods to allow for controlled, large-scale biomarker discovery studies to be performed. In this manuscript, twelve amino acids were quantitated from exercise-induced excreted sweat held at room temperature or a simulated body temperature of 37 °C for up to 90 min. The data illustrate a large dynamic range exists among amino acids in sweat. Additionally, the amino acid quantities vary across individuals and among the same individual under different storage conditions, with alanine, arginine, and threonine showing a significant statistical difference between sampling events (p < 0.05). Furthermore, the results establish amino acids are relatively invariant, at both storage temperatures tested, for up to 90 min illustrated by <10% (15/156) of the amino acids measurements demonstrating change greater than 10% from the time zero value. An untargeted metabolomics approach was also applied to the data set to evaluate global changes to the metabolome. The results show more than 88% of all data points fall within the established limits, regardless of temperature condition and ionization mode. Collectively, this study demonstrates that sweat is largely invariant at two distinct temperatures for up to 90 min. These results establish sweat collection and sample handling is possible for up to 90 min with minimal changes in metabolite abundances.


Subject(s)
Metabolome/physiology , Metabolomics/methods , Sweat/metabolism , Amino Acids/analysis , Amino Acids/metabolism , Biomarkers/analysis , Biomarkers/metabolism , Chromatography, Liquid/methods , Exercise/physiology , Humans , Hydrophobic and Hydrophilic Interactions , Male
11.
PLoS One ; 13(11): e0203133, 2018.
Article in English | MEDLINE | ID: mdl-30383773

ABSTRACT

Sweat is a biofluid with several attractive attributes. However, investigation into sweat for biomarker discovery applications is still in its infancy. To add support for the use of sweat as a non-invasive media for human performance monitoring, volunteer participants were subjected to a physical exertion model using a treadmill. Following exercise, sweat was collected, aliquotted, and analyzed for metabolite and protein content via high-resolution mass spectrometry. Overall, the proteomic analysis illustrates significant enrichment steps will be required for proteomic biomarker discovery from single sweat samples as protein abundance is low in this medium. Furthermore, the results indicate a potential for protein degradation, or a large number of low molecular weight protein/peptides, in these samples. Metabolomic analysis shows a strong correlation in the overall abundance among sweat metabolites. Finally, hierarchical clustering of participant metabolite abundances show trends emerging, although no significant trends were observed (alpha = 0.8, lambda = 1 standard error via cross validation). However, these data suggest with a greater number of biological replicates, stronger, statistically significant results, can be obtained. Collectively, this study represents the first to simultaneously use both proteomic and metabolomic analysis to investigate sweat. These data highlight several pitfalls of sweat analysis for biomarker discovery applications.


Subject(s)
Exercise , Metabolomics , Proteomics , Sweat/metabolism , Adolescent , Adult , Humans , Metabolome , Metabolomics/methods , Middle Aged , Military Personnel , Physical Endurance , Pilot Projects , Proteome/analysis , Proteome/metabolism , Proteomics/methods , Sweat/chemistry , Young Adult
12.
Small ; 14(12): e1703334, 2018 03.
Article in English | MEDLINE | ID: mdl-29394467

ABSTRACT

This paper introduces super absorbent polymer valves and colorimetric sensing reagents as enabling components of soft, skin-mounted microfluidic devices designed to capture, store, and chemically analyze sweat released from eccrine glands. The valving technology enables robust means for guiding the flow of sweat from an inlet location into a collection of isolated reservoirs, in a well-defined sequence. Analysis in these reservoirs involves a color responsive indicator of chloride concentration with a formulation tailored to offer stable operation with sensitivity optimized for the relevant physiological range. Evaluations on human subjects with comparisons against ex situ analysis illustrate the practical utility of these advances.


Subject(s)
Colorimetry/methods , Microfluidics/methods , Polymers/chemistry , Sweat/chemistry , Humans , Lab-On-A-Chip Devices , Skin/metabolism
13.
J Breath Res ; 11(4): 047111, 2017 Nov 29.
Article in English | MEDLINE | ID: mdl-29018179

ABSTRACT

Hypoxia-like incidents in-flight have increased over the past decade causing severe safety concerns across the aviation community. As a result, the need to monitor flight crews in real-time for the onset of hypoxic conditions is paramount for continued aeronautical safety. Here, hypoxic events were simulated in the laboratory via a reduced oxygen-breathing device to determine the effect of recovery gas oxygen concentration (21% and 100%) on exhaled breath volatile organic compound composition. Data from samples collected both serially (throughout the exposure), prior to, and following exposures yielded 326 statistically significant features, 203 of which were unique. Of those, 72 features were tentatively identified while 51 were verified with authentic standards. A comparison of samples collected serially between recovery and hypoxia time points shows a statistically significant reduction in exhaled breath isoprene (2-methyl-1,3-butadiene, log2 FC -0.399, p = 0.005, FDR = 0.034, q = 0.033), however no significant difference in isoprene abundance was observed when comparing recovery gases (21% or 100% O2, p = 0.152). Furthermore, examination of pre-/post-exposure 1 l bag breath samples illustrate an overall increase in exhaled isoprene abundance post-exposure (log2 FC 0.393, p = 0.005, FDR = 0.094, q = 0.033) but again no significant difference between recovery gas (21% and 100%, p = 0.798) was observed. A statistically significant difference in trend was observed between isoprene abundance and recovery gases O2 concentration when plotted against minimum oxygen saturation (p = 0.0419 100% O2, p = 0.7034 21% O2). Collectively, these results suggest exhaled isoprene is dynamic in the laboratory ROBD setup and additional experimentation will be required to fully understand the dynamics of isoprene in response to acute hypoxic stress.


Subject(s)
Breath Tests/methods , Butadienes/analysis , Exhalation , Hemiterpenes/analysis , Hypoxia/diagnosis , Pentanes/analysis , Stress, Physiological , Adult , Humans , Hypoxia/blood , Male , Oxygen/blood , Reference Standards , Time Factors , Young Adult
14.
Anal Chem ; 82(11): 4386-95, 2010 Jun 01.
Article in English | MEDLINE | ID: mdl-20443621

ABSTRACT

The goal of this work was to design and implement a prototype software tool for the visualization and analysis of small molecule metabolite GC-MS and LC-MS data for biomarker discovery. The key features of the Metabolite Differentiation and Discovery Lab (MeDDL) software platform include support for the manipulation of large data sets, tools to provide a multifaceted view of the individual experimental results, and a software architecture amenable to modification and addition of new algorithms and software components. The MeDDL tool, through its emphasis on visualization, provides unique opportunities by combining the following: easy use of both GC-MS and LC-MS data; use of both manufacturer specific data files as well as netCDF (network Common Data Form); preprocessing (peak registration and alignment in both time and mass); powerful visualization tools; and built in data analysis functionality.


Subject(s)
Computer Graphics , Mass Spectrometry/methods , Software , Algorithms , Animals , Biomarkers/analysis , Chromatography, Gas , Chromatography, Liquid , Male , Principal Component Analysis , Rats
15.
J Biol Chem ; 280(44): 36962-9, 2005 Nov 04.
Article in English | MEDLINE | ID: mdl-16096277

ABSTRACT

Single in-frame amber (UAG) codons are found in the genes encoding MtmB, MtbB, or MttB, the methyltransferases initiating methane formation from monomethylamine, dimethylamine, or trimethylamine, respectively, in certain Archaea. The crystal structure of MtmB demonstrated that the amber codon codes for pyrrolysine, the 22nd genetically encoded amino acid found in nature. Previous attempts to visualize the amber-encoded residue by mass spectrometry identified only lysine, leaving information on the existence and structure of pyrrolysine resting entirely on crystallography of a single protein. Here we report successful mass spectral characterization of naturally occurring pyrrolysine and the first demonstration of the amber-encoded residue in proteins other than MtmB. The sequencing of chymotryptic fragments from acetonitrile-denatured proteins by tandem mass spectrometry revealed the mass of the amber-encoded residue in MtmB, MtbB, and MttB as 237.2 +/- 0.2 Da. Fourier transform ion cyclotron resonance mass spectrometry produced an accurate measurement for the pyrrolysyl-residue as 237.1456 Da, within error limits of the predicted mass based on the empirical formula C(12)H(19)N(3)O(2). These measurements support the structure of pyrrolysine in MtmB as 4-methylpyrroline-5-carboxylate in amide linkage with the (epsilon)N of lysine but not the alternative structure in which the 4-substituent of the pyrroline ring is an amine group. The presence of pyrrolysine with statistically identical mass in all three methyltransferases is in keeping with the proposed direct incorporation of pyrrolysine into protein during translation of the UAG codon and suggests that MtbB and MttB may exploit the unusual electrophilicity of pyrrolysine during catalysis.


Subject(s)
Archaeal Proteins/chemistry , Codon , Lysine/analogs & derivatives , Methanosarcina barkeri/enzymology , Methyltransferases/chemistry , Amides/metabolism , Archaeal Proteins/genetics , Archaeal Proteins/metabolism , Chromatography, Liquid , Chymotrypsin/metabolism , Lysine/chemistry , Lysine/metabolism , Methanosarcina barkeri/genetics , Methyltransferases/genetics , Methyltransferases/metabolism , Peptide Fragments/metabolism , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Spectroscopy, Fourier Transform Infrared
SELECTION OF CITATIONS
SEARCH DETAIL
...