Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Causal Inference ; 12(1)2024 Jan.
Article in English | MEDLINE | ID: mdl-38361970

ABSTRACT

Many software packages have been developed to assist researchers in drawing directed acyclic graphs (DAGs), each with unique functionality and usability. We examine five of the most common software to generate DAGs: TikZ, DAGitty, ggdag, dagR, and igraph. For each package, we provide a general description of its background, analysis and visualization capabilities, and user-friendliness. Additionally in order to compare packages, we produce two DAGs in each software, the first featuring a simple confounding structure, while the second includes a more complex structure with three confounders and a mediator. We provide recommendations for when to use each software depending on the user's needs.

2.
Am J Cardiol ; 196: 22-30, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37058874

ABSTRACT

Adverse outcomes in tricuspid regurgitation (TR) have been associated with advanced regurgitation severity and right-sided cardiac remodeling, and late referrals for tricuspid valve surgery in TR have been associated with increase in postoperative mortality. The purpose of this study was to evaluate baseline characteristics, clinical outcomes, and procedural utilization of a TR referral population. We analyzed patients with a diagnosis of TR referred to a large TR referral center between 2016 and 2020. We evaluated baseline characteristics stratified by TR severity and analyzed time-to-event outcomes for a composite of overall mortality or heart-failure hospitalization. In total, 408 patients were referred with a diagnosis of TR: the median age of the cohort was 79 years (interquartile range 70 to 84), and 56% were female. In patients evaluated on a 5-grade scale, 10.2% had ≤moderate TR; 30.7% had severe TR; 11.4% had massive TR, and 47.7% had torrential TR. Increasing TR severity was associated with right-sided cardiac remodeling and altered right ventricular hemodynamics. In multivariable Cox regression analysis, New York Heart Association class symptoms, history of heart failure hospitalization, and right atrial pressure were associated with the composite outcome. One-third of patients referred underwent transcatheter tricuspid valve intervention (19%) or surgery (14%); patients who underwent transcatheter tricuspid valve intervention had greater preoperative risk than that of patients who underwent surgery. In conclusion, in patients referred for evaluation of TR, there were high rates of massive and torrential regurgitation and advanced right ventricle remodeling. Symptoms and right atrial pressure are associated with clinical outcomes in follow-up. There were significant differences in baseline procedural risk and eventual therapeutic modality.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnosis , Ventricular Remodeling , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Tricuspid Valve/surgery , Severity of Illness Index , Cardiac Catheterization/adverse effects
3.
Diabetes Care ; 35(4): 706-10, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22357189

ABSTRACT

OBJECTIVE: To improve glucose sensor accuracy in subjects with type 1 diabetes by using multiple sensors and to assess whether the benefit of redundancy is affected by intersensor distance. RESEARCH DESIGN AND METHODS: Nineteen adults with type 1 diabetes wore four Dexcom SEVEN PLUS subcutaneous glucose sensors during two 9-h studies. One pair of sensors was worn on each side of the abdomen, with each sensor pair placed at a predetermined distance apart and 20 cm away from the opposite pair. Arterialized venous blood glucose levels were measured every 15 min, and sensor glucose values were recorded every 5 min. Sensors were calibrated once at the beginning of the study. RESULTS: The use of four sensors significantly reduced very large errors compared with one sensor (0.4 vs. 2.6% of errors ≥50% from reference glucose, P < 0.001) and also improved overall accuracy (mean absolute relative difference, 11.6 vs. 14.8%, P < 0.001). Using only two sensors also significantly improved very large errors and accuracy. Intersensor distance did not affect the function of sensor pairs. CONCLUSIONS: Sensor accuracy is significantly improved with the use of multiple sensors compared with the use of a single sensor. The benefit of redundancy is present even when sensors are positioned very closely together (7 mm). These findings are relevant to the design of an artificial pancreas device.


Subject(s)
Biosensing Techniques/instrumentation , Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Abdomen , Adult , Biosensing Techniques/standards , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/standards , Calibration , Diabetes Mellitus, Type 1/therapy , Equipment Design , Equipment Failure Analysis/methods , Female , Humans , Male , Reference Values , Research Design , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...