1.
Sensors (Basel) ; 24(3)2024 Feb 04.
Article in English | MEDLINE | ID: mdl-38339729

ABSTRACT

(1) Background: An optical simulator able to provide a repeatable signal with desired characteristics as an input to a photoplethysmographic (PPG) device is presented in order to compare the performance of different PPG devices and also to test the devices with PPG signals available in online databases. (2) Methods: The optical simulator consists of an electronic board containing a photodiode and LEDs at different wavelengths in order to simulate light reflected by the body; the PPG signal taken from the chosen database is reproduced by the electronic board, and the board is used to test a wearable PPG medical device in the form of earbuds. (3) Results: The PPG device response to different average and peak-to-peak signal amplitudes is shown in order to assess the device sensitivity, and the fidelity in tracking the actual heart rate is also investigated. (4) Conclusions: The developed optical simulator promises to be an affordable, flexible, and reliable solution to test PPG devices in the lab, allowing the testing of their actual performances thanks to the possibility of using PPG databases, thus gaining useful and significant information before on-the-field clinical trials.


Subject(s)
Algorithms , Photoplethysmography , Heart Rate/physiology , Artifacts , Databases, Factual , Signal Processing, Computer-Assisted
2.
Sensors (Basel) ; 23(8)2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37112460

ABSTRACT

A frequency-modulated continuous-wave radar for short-range target imaging, assembling a transceiver, a PLL, an SP4T switch, and a serial patch antenna array, was realized. A new algorithm based on a double Fourier transform (2D-FT) was developed and compared with the delay and sum (DAS) and multiple signal classification (MUSIC) algorithms proposed in the literature for target detection. The three reconstruction algorithms were applied to simulated canonical cases evidencing radar resolutions close to the theoretical ones. The proposed 2D-FT algorithm exhibits an angle of view greater than 25° and is five times faster than DAS and 20 times faster than the MUSIC one. The realized radar shows a range resolution of 55 cm and an angular resolution of 14° and is able to correctly identify the positions of single and multiple targets in realistic scenarios, with errors lower than 20 cm.

3.
Sensors (Basel) ; 23(2)2023 Jan 08.
Article in English | MEDLINE | ID: mdl-36679507

ABSTRACT

The problem of water scarcity affects many areas of the world due to water mismanagement and overconsumption and, more recently, to climate change. Monitoring the integrity of distribution systems is, therefore, increasingly important to avoid the waste of clean water. This paper presents a new signal processing technique for enhancing the performance of the methodology of leak detection in water distribution pipes based on time domain reflectometry (TDR). The new technique is based on a particular kind of TDR inversion (spatial TDR) based on a "gray-box" lumped parameter model of the system. The model does not include, e.g., radiative phenomena, non-TEM (transverse electromagnetic) modes etc. but is capable of reproducing accurately the complicated reflectograms obtained by a TDR leak detection system assuming a proper profile of capacitance per unit length along the sensing element. Even more importantly, the model is identified using only the reflectograms taken by the system with very little prior information about the system components. The developed technique is able to estimate with good accuracy, from reflectograms with unclear or ambiguous interpretation, the position and the extension of a region where water is located. The measurement is obtained without prior electromagnetic characterization of the TDR system components and without the need of modeling or quantifying a number of electromagnetic effects typical of on-site measurements.


Subject(s)
Water Pipe Smoking , Signal Processing, Computer-Assisted , Water
4.
Sensors (Basel) ; 22(17)2022 Aug 25.
Article in English | MEDLINE | ID: mdl-36080855

ABSTRACT

The aim of this work is to propose two different and integrated sensors for the structural health monitoring of concrete beams. In particular, a diffused sensing element and a split ring resonator network are presented. The first sensor is able to detect the variations in the dielectric properties of the concrete along the whole beam length, for a diffuse monitoring both during the important concrete curing phase and also for the entire life cycle of the concrete beams. The resonators instead work punctually, in their surroundings, allowing an accurate evaluation of the permittivity both during the drying phase and after. This allows the continuous monitoring of any presence of water both inside the concrete beam and at points that can be critical, in the case of beams in dams, bridges or in any case subject to a strong presence of water which could lead to deterioration, or worse, cause serious accidents. Moreover, the punctual sensors are able to detect the presence of cracks in the structure and to localize them.


Subject(s)
Water
5.
Sensors (Basel) ; 22(6)2022 Mar 10.
Article in English | MEDLINE | ID: mdl-35336317

ABSTRACT

In this work, the dielectric permittivity of four kinds of wood (Fir, Poplar, Oak, and Beech Tree), used in Italian Artworks and structures, was characterized at different humidity levels. Measurements were carried out using three different probes connected to a bench vector network analyzer: a standard WR90 X-band waveguide, a WR430 waveguide, and an open-ended coaxial probe. In particular, we investigated the dispersion model for the four wood species, showing how a log-fit model of the open-ended data presents a determination coefficient R2 > 0.990 in the 1−12 GHz frequency range. This result has proven helpful to fill the frequency gap between the measurements obtained at different water contents with the two waveguide probes showing an R2 > 0.93. Furthermore, correlating the log-fit vertical shift with the water content, it was possible to find a calibration curve with a linear characteristic. These experimental results will be helpful for on-site non-invasive water monitoring of wooden artworks or structures. Moreover, the final results show how the open-ended coaxial probe, with a measurement deviation lower than 7% from the waveguide measurements, may be used directly as a non-invasive sensor for on-site measurements.


Subject(s)
Water , Wood , Calibration
6.
Sci Rep ; 10(1): 18659, 2020 10 29.
Article in English | MEDLINE | ID: mdl-33122808

ABSTRACT

Autism spectrum disorder (ASD) is a neurodevelopmental condition characterized by early impairment in social and communication domains and autonomic nervous system unbalance. This study evaluated heart rate (HR) as a possible indicator of stress response in children with ASD as compared to children with language disorder (LD). Twenty-four patients [mean age = 42.62 months; SD = 8.14 months,12 with ASD (10 M/2F) and 12 with LD (8 M/4F)] underwent clinical [Leiter International Performance Scale-Revised, Autism Diagnostic Observation Schedule, second edition (ADOS-2)] and physiological evaluation (HR monitoring) during five interactive activities, while wearing an HR measurement device. IQ (ASD:IQ = 103.33 ± 12.85 vs. LD:IQ = 111.00 ± 8.88, p = 0.103) and fluid reasoning on the Leiter-R Scale were within the normal range in all subjects. Increased HR during the third activity (ADOS-2 bubble play) significantly correlated with autistic symptoms (r = 0.415; p = 0.044), while correlations between ADOS-2 total score and HR during the first activity (ADOS-2 free play; r = 0.368; p = 0.077), second activity (Leiter-R figure ground subscale; r = 0.373, p = 0.073), and fifth activity (ADOS-2 anticipation of a routine with objects; r = 0.368; p = 0.076) did not quite reach statistical significance. Applying a linear regression model, we found that the ADOS-2 total score significantly influenced HR variations (p = 0.023). HR monitoring may provide a better understanding of the stress-provoking situations for children with ASD. Furthermore, it could help clinicians detect the impact of the stressful condition on the autistic core and adress treatment strategy.


Subject(s)
Autism Spectrum Disorder/physiopathology , Heart Rate , Wearable Electronic Devices , Child , Female , Humans , Male
7.
Sensors (Basel) ; 20(16)2020 Aug 12.
Article in English | MEDLINE | ID: mdl-32806534

ABSTRACT

Unobtrusive and continuous monitoring of vital signs is becoming more and more important both for patient monitoring in the home environment and for sports activity tracking. Even though many gadgets and clinical systems exist, the need for simple, low-cost and easily applicable solutions still remains, especially in view of a more widespread use within everyone's reach. The paper presents a fully wearable and wireless sensorized belt, suitable to simultaneously acquire respiratory and cardiac signals employing a single acquisition channel. The adopted method relies on a 50-kHz current injected in the subject thorax through a couple of textile electrodes and on envelope detection of the trans-thoracic voltage acquired from a couple of different embedded electrodes. The resulting signal contains both the baseband electrocardiogram (ECG) signal and the trans-thoracic impedance signal, which encodes respiratory acts. The two signals can be easily separated through suitable filtering and the cardio-respiratory rates extracted. The proposed solution yields performances comparable to those of a spirometer and a two-lead ECG. The whole system, with a realization cost below 100 €, a wireless interface, and several hours (or even days) of autonomy, is a suitable candidate for everyday use, especially if complemented by motion artifact removal techniques, currently under implementation.


Subject(s)
Monitoring, Physiologic , Wearable Electronic Devices , Cardiorespiratory Fitness/physiology , Electrocardiography , Electrodes , Humans , Signal Processing, Computer-Assisted , Textiles
8.
Sensors (Basel) ; 20(12)2020 Jun 20.
Article in English | MEDLINE | ID: mdl-32575677

ABSTRACT

This work tests the ability of fmcw radar to measure the respiratory rate and the heartbeat of a subject in challenging indoor scenarios. To simulate a realistic configuration for ambient assisted living (AAL) applications, in which the thorax orientation towards the antenna is typically unknown, four different scenarios were considered. Measurements were performed on five volunteers positioned with the chest, left, back, and right side facing the antenna, respectively. The 5 . 8 radar and the antennas used for the measurements were suitably designed for the considered application. To obtain a low cost and compact system, series-fed arrays were preferred over other antenna topologies. The geometry of the patches was opportunely shaped to reduce the side lobe level (SLL) and increase the bandwidth, thus ensuring good system performances. In all scenarios, the vital signs extracted from the radar signal were compared with the ones collected by a photoplethysmograph and a respiratory belt, used as references. A statistical analysis of the measured data on the different subjects and orientations was performed, showing that the radar was able to measure with high accuracy both the respiratory rate and the heartbeat in all considered configurations.


Subject(s)
Patient Positioning , Radar , Thorax , Vital Signs , Heart Rate , Humans , Respiratory Rate
9.
Sensors (Basel) ; 20(10)2020 May 16.
Article in English | MEDLINE | ID: mdl-32429375

ABSTRACT

One of the major goals of Health 4.0 is to offer personalized care to patients, also through real-time, remote monitoring of their biomedical parameters. In this regard, wearable monitoring systems are crucial to deliver continuous appropriate care. For some biomedical parameters, there are a number of well established systems that offer adequate solutions for real-time, continuous patient monitoring. On the other hand, monitoring skin hydration still remains a challenging task. The continuous monitoring of this physiological parameter is extremely important in several contexts, for example for athletes, sick people, workers in hostile environments or for the elderly. State-of-the-art systems, however, exhibit some limitations, especially related with the possibility of continuous, real-time monitoring. Starting from these considerations, in this work, the feasibility of an innovative time-domain reflectometry (TDR)-based wearable, skin hydration sensing system for real-time, continuous monitoring of skin hydration level was investigated. The applicability of the proposed system was demonstrated, first, through experimental tests on reference substances, then, directly on human skin. The obtained results demonstrate the TDR technique and the proposed system holds unexplored potential for the aforementioned purposes.


Subject(s)
Skin , Wearable Electronic Devices , Aged , Feasibility Studies , Humans , Monitoring, Physiologic , Water/analysis
10.
Sensors (Basel) ; 19(23)2019 Nov 22.
Article in English | MEDLINE | ID: mdl-31766596

ABSTRACT

In this paper, the characterization of the main techniques and transducers employed to measure local and global strains induced by uniaxial loading of murine tibiae is presented. Micro strain gauges and digital image correlation (DIC) were tested to measure local strains, while a moving coil motor-based length transducer was employed to measure relative global shortening. Local strain is the crucial parameter to be measured when dealing with bone cell mechanotransduction, so we characterized these techniques in the experimental conditions known to activate cell mechanosensing in vivo. The experimental tests were performed using tibia samples excised from twenty-two C57BL/6 mice. To evaluate measurement repeatability we computed the standard deviation of ten repetitive compressions to the mean value. This value was lower than 3% for micro strain gauges, and in the range of 7%-10% for DIC and the length transducer. The coefficient of variation, i.e., the standard deviation to the mean value, was about 35% for strain gauges and the length transducer, and about 40% for DIC. These results provided a comprehensive characterization of three methodologies for local and global bone strain measurement, suggesting a possible field of application on the basis of their advantages and limitations.


Subject(s)
Tibia/physiology , Animals , Biomechanical Phenomena/physiology , Mechanotransduction, Cellular/physiology , Mice , Mice, Inbred C57BL , Stress, Mechanical , Transducers , Weight-Bearing/physiology
11.
IEEE Trans Biomed Eng ; 50(3): 295-304, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12669986

ABSTRACT

The exposure of a subject in the far field of radiofrequency sources operating in the 10-900-MHz range has been studied. The electromagnetic field inside an anatomical heterogeneous model of the human body has been computed by using the finite-difference time-domain method; the corresponding temperature increase has been evaluated through an explicit finite-difference formulation of the bio-heat equation. The thermal model used, which takes into account the thermoregulatory system of the human body, has been validated through a comparison with experimental data. The results show that the peak specific absorption rate (SAR) as averaged over 10 g has about a 25-fold increase in the trunk and a 50-fold increase in the limbs with respect to the whole body averaged SAR (SARWB). The peak SAR as averaged over 1 g, instead, has a 30- to 60-fold increase in the trunk, and up to 135-fold increase in the ankles, with respect to SARWB. With reference to temperature increases, at the body resonance frequency of 40 MHz, for the ICNIRP incident power density maximum permissible value, a temperature increase of about 0.7 degrees C is obtained in the ankles muscle. The presence of the thermoregulatory system strongly limits temperature elevations, particularly in the body core.


Subject(s)
Body Temperature/radiation effects , Models, Biological , Organ Specificity , Radio Waves , Radiotherapy Planning, Computer-Assisted/methods , Whole-Body Counting/methods , Absorption , Anatomy, Cross-Sectional/standards , Body Temperature Regulation/radiation effects , Computer Simulation , Dose-Response Relationship, Radiation , Humans , Sensitivity and Specificity , Temperature , Whole-Body Irradiation/methods