Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Plast Reconstr Surg Glob Open ; 12(5): e5785, 2024 May.
Article in English | MEDLINE | ID: mdl-38741599

ABSTRACT

Background: Indocyanine green lymphography (ICGL) generally has a nonlinear pattern in advanced-stage lymphedema. Despite the lack of a linear pattern ICGL, lymphatic vessels have been discovered in several studies. The purpose of this work was to establish lymphatic mapping utilizing information from the contralateral limb and to illustrate the symmetry of lymphatic systems. Methods: Data were retrospectively collected from 81 patients who underwent lymphaticovenular anastomosis (LVA) using the contralateral mapping technique during 2018 to 2022. The sensitivity, specificity, accuracy, and negative and positive predictive values of this technique were calculated and analyzed. Results: Lymphatic vessels were identified in 85.2% of the upper and 82.3% of the lower limb presumed sites using the contralateral mapping technique. The positive predictive value for successful LVA anastomosis was 93.8% for upper limb and 92.3% for lower limb cases. This mirror image technique's accuracy was 91.7% and 91.1%, for the upper limb and lower limb group, respectively. Between reoperative and new LVA cases, there was no statistically significant difference in the number, type, or diameter of lymphatic vessels or number of anastomoses. Conclusions: LVA with contralateral mapping technique is an effective method for patients with high-stage lymphedema with a nonlinear pattern on ICGL.

2.
J Craniofac Surg ; 34(1): 187-197, 2023.
Article in English | MEDLINE | ID: mdl-36168132

ABSTRACT

Computer-assisted surgery (CAS) has been introduced to mandible reconstruction with fibular-free flap in cutting guide placement. When CAS cooperates with different plate fixations, the results show various degrees of errors by which this study aimed to evaluate. Mock surgeries were conducted in 3D-printed mandibles with 2 types of defects, limited or extensive, reconstructed from 2 ameloblastoma patients. Three types of fixations, miniplate, manually bending reconstruction plate, and patient-specific plate, are tested, each of which was performed 3 times in each type of defect, adding up to 18 surgeries. One with the least errors was selected and applied to patients whose 3D-printed mandibles were derived. Finally, in vivo errors were compared with the mock. In limited defect, average errors show no statistical significance among all types. In extensive defect, patient-specific plate had a significantly lower average condylar error than manually bending reconstruction plate and miniplate (8.09±2.52 mm vs. 25.49±2.72 and 23.13±13.54 mm, respectively). When patient-specific plate was applied in vivo , the errors were not significantly different from the mock. Patient-specific plates that cooperated with CAS showed the least errors. Nevertheless, manually bent reconstruction plates and miniplates could be applied in limited defects with caution.


Subject(s)
Ameloblastoma , Free Tissue Flaps , Mandibular Reconstruction , Humans , Mandibular Reconstruction/methods , Mandible/surgery , Computer-Aided Design , Ameloblastoma/surgery , Fibula , Bone Plates
3.
BMC Surg ; 22(1): 306, 2022 Aug 08.
Article in English | MEDLINE | ID: mdl-35941680

ABSTRACT

BACKGROUND: To develop a perfused cadaveric model for trauma surgery simulation, and to evaluate its efficacy in trauma resuscitation advanced surgical skills training. METHODS: Fourteen fourth-year general surgery residents attended this workshop at Siriraj Hospital (Bangkok, Thailand). Inflow and outflow cannulae and a cardiopulmonary bypass pump were used to create the perfusion circuit. Inflow was achieved by cannulating the right common carotid artery, and outflow by cannulation of both the right common femoral artery and the internal jugular vein. Arterial line monitoring was used to monitor resuscitation response and to control perfusion pressure. The perfusion solution comprised saline solution mixed 1:1 with glycerol (50%) and water with red food dye added. Advanced surgical skills during life-threatening injuries and damage control resuscitation operations were practiced starting from the airway to the neck, chest, peripheral vessels, abdomen, and pelvis. Resuscitative endovascular balloon occlusion of the aorta (REBOA) was also practiced. Post-workshop survey questions were grouped into three categories, including comparison with previous training methods; the realism of anatomical correlation and procedures; and, satisfaction, safety, and confidence. All questions and tasks were discussed among all members of the development team, and were agreed upon by at least 90% of experts from each participating medical specialty/subspecialty. RESULTS: The results of the three main groups of post-workshop survey questions are, as follows: (1) How the training compared with previous surgical training methods-mean score: 4.26/5.00, high score: 4.73/5.00; (2) Realism of anatomical correlation and procedures-mean score: 4.03/5.00, high score: 4.60/5.00; and, (3) Satisfaction, safety, and confidence-mean score: 4.24/5.00, high score: 4.47/5.00. CONCLUSION: The developed perfused cadaveric model demonstrated potential advantages over previously employed conventional surgical training techniques for teaching vascular surgery at our center as evidenced by the improvement in the satisfaction scores from students attending perfused cadaveric training compared to the scores reported by students who attended earlier training sessions that employed other training techniques. Areas of improvement included 'a more realistic training experience' and 'improved facilitation of decision-making and damage control practice during trauma surgery'.


Subject(s)
Balloon Occlusion , Endovascular Procedures , Balloon Occlusion/methods , Cadaver , Endovascular Procedures/methods , Humans , Resuscitation/methods , Thailand
4.
J Craniofac Surg ; 33(3): 951-955, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35727650

ABSTRACT

ABSTRACT: Even though there are many options for mandibular reconstruction, a free fibula osteocutaneous flap is regarded as the most frequently used flap. Despite having some previous anatomical studies pertaining to syndesmotic ligaments, there is no study pointing out that surgical landmarks can be used while free fibula osteocutaneous flaps are performed and used for surgical landmarks in order to avoid syndesmotic ligament injuries. Therefore, this study investigates the characteristics and relationship between inferior syndesmotic ligaments and fibula in cadavers. A total of 140 legs were obtained from 83 embalmed cadavers as well as other soft ones, which were donated for the inferior tibiofibular syndes- motic system's study. Detailed dissection and measurement of each ligament's distance to the end of the fibula and lateral malleolus were performed. Distances from the distal end of the fibula to anterior inferior tibiofibular ligament, posterior inferior tibiofibular, and inferior transverse ligament, and the lower border of the interosseous membrane are 3.5 ±â€Š0.4 cm, 3.4 ±â€Š0.5 cm, 1.9 ±â€Š0.4 cm, and 5 ±â€Š1 cm (mean ±â€ŠSD), respectively. Distance from the most distal part of the fibula to lateral malleolus is 1.6 ±â€Š0.4 cm (mean ±â€ŠSD). Thus, the remaining distance of the fibular should be left at least 4 cm without disrupting the syndesmotic ligament complex. It is argued that the lateral malleolus can be applied as a surgical landmark while harvesting fibula.


Subject(s)
Fibula , Free Tissue Flaps , Ankle Joint/anatomy & histology , Ankle Joint/surgery , Cadaver , Fibula/surgery , Humans , Ligaments, Articular/anatomy & histology , Ligaments, Articular/injuries
5.
Plast Reconstr Surg Glob Open ; 8(12): e3330, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33425628

ABSTRACT

The outcome of autologous lymph node (LN) transfer has depended on the number of LNs in the donor site. Unknown accuracy of the LN counting method has thrown some doubts on the reliability of the previous statistics. This study aimed to assess the accuracy of naked eye (NK) and stereo microscopy (SM) as tools for LN count. METHODS: In total, 40 vascularized submental LN flaps were harvested from 23 fresh cadavers. The colored polymer was injected into the external carotid arteries before the harvest. LNs in each flap were counted by NK, SM, and histology in sequential order. RESULTS: An estimated 175 LNs were confirmed, 4.4 ± 1.8 per flap. NK sensitivity was 33.7% compared with that of SM at 63.5%. Both methods missed all micro-lymph nodes (micro-LNs), contributing to 5.1% (9 nodes) of all LNs. Non-LN structures (647 negative counts) were composed of fat lobules, salivary gland lobules, and muscle fibers. NK specificity was 98.0%, compared with that of SM at 96.1%. SM showed a higher false positive rate at 14.3%, compared with NK at 7.4%. False positive counts were located mostly in Ib sublevel. CONCLUSIONS: NK and SM are imperfect tools for LN count due to poor sensitivity. If the method needs to be applied, points of considerations are (1) undetectable micro-LNs, (2) interposition of LNs with the digastric muscle and submandibular salivary gland, (3) confusion of LNs with lobules of salivary gland supplied by glandular artery or fat lobules supplied by lobular artery.

6.
J Surg Oncol ; 121(1): 144-152, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31638275

ABSTRACT

BACKGROUND AND OBJECTIVES: Development of vascularized submental lymph node (VSLN) flap has encountered dilemmas; (a) whether to include skin paddle, (b) how to reduce the harvest area while gaining most lymph nodes. To answer, these structures were studied; submental perforator, lymph nodes in neck-level I and anterior belly of digastric muscle (ABDM). METHODS: Forty VSLN flaps were harvested from 23 cadavers. The lymph nodes and arterial supply were studied macro- and microscopically. The nodes were classified by arterial supplies, location along the longitudinal axis and relationship with ABDM. RESULTS: VSLN flap had 4.4 lymph nodes by average (range 1-8) predominantly located in the posterior three-quarter of the flap. Half of the submental perforators were originated deep to ABDM. they circumvent the muscle, supplied much of the nodes in neck sublevel Ia before reaching the skin. While sublevel Ib located the most surgically accessible submental nodes. Most of their arterial supply was branched from submental perforator lateral to ABDM, not directly from the submental artery. CONCLUSION: The flap could be reduced to the posterior three-quarter of the original area. Skin paddle should be included to serve as an indirect lymph node monitor. If Ia lymph nodes are to be included, ABDM should be sacrified.


Subject(s)
Lymph Nodes/anatomy & histology , Lymph Nodes/blood supply , Neck Muscles/anatomy & histology , Skin/blood supply , Surgical Flaps/blood supply , Aged , Arteries/anatomy & histology , Cadaver , Dissection , Female , Humans , Lymph Nodes/surgery , Male , Middle Aged , Neck Muscles/blood supply
7.
Cancer Med ; 4(10): 1514-24, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26247407

ABSTRACT

Twisting Tourniquet(©) or in Thai "Schnogh" is a new invention for compression therapy of lymphedema. Twisting Tourniquet(©) Technique (TTT) is totally noninvasive for lymphedema management. After the amazing successful evidence in the first series of 28 patients, we have conducted preliminary studies in lymphedema clinics. It was found that the combination of gradually increasing constriction force by Schnogh until desired pressure was reached and maintained for 15 min, followed by a 5-min release, doing repeatedly this compression-decompression for at least 10 sessions a day, can generate acceptable results. The aim of the study was to evaluate the scientific effectiveness and establish a treatment protocol of TTT proposed as a therapeutic approach for clinical management of lymphedema. During 2006-2013, from over 3500 patients, 647 with primary/secondary lymphedema passed inclusion criteria, 307 for upper, and 340 for lower extremity. In the 5-day course of TTT, each day patients underwent 10 sessions of a 15-min compression followed by a 5-min decompression. Vegan diet was encouraged as an adjuvant therapy. Among lymphedema patients whose spectrum of edema severity ranged from mild to gigantic, TTT yielded an average volume reduction rate (VR) at 50.2% and 55.6%, making the average edema reduction volume attained at 463 and 1856 mL for upper and lower limb, respectively. The uniformed practice by Schnogh which supports a continual compression-decompression maneuver over 3.5 h daily for five consecutive days could induce an average VR at above half of the swelling in extremities of 647 patients. Schnogh is therefore effective in clinical management of lymphedema under TTT treatment of fibroblastic interstitium.


Subject(s)
Lymphedema/therapy , Tourniquets , Adolescent , Adult , Aged , Aged, 80 and over , Child , Clinical Protocols , Diet, Vegan , Female , Humans , Lower Extremity , Male , Middle Aged , Thailand , Treatment Outcome , Upper Extremity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...