Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 3837, 2024 02 15.
Article in English | MEDLINE | ID: mdl-38360840

ABSTRACT

This study analyzed the migration of a calcar-guided short stem to determine the course of very early migration, as well as evaluated the effect of an additional calcium phosphate (CP) coating on a titanium plasma spray (TPS) coating, which has not been analyzed previously. Sixty patients were enrolled in this study and were treated with the A2 calcar-guided short stem. The implant coating was randomized with either the TPS or an additional CP coating, and radiostereometric analysis was performed with the baseline measurement before initial weight-bearing, along with follow-up examinations at 1 week, 6 weeks, 3 months, and 6 months. Implant migrations were 0.27 mm (standard deviation [SD], 0.13 mm) and 0.74 mm (SD, 1.11 mm) at 1 week and 6 months post-surgery, respectively, and 65% and 87% of the implants reached their final position 1 week and 6 weeks after surgery, respectively. After 6 weeks, 3 months, and 6 months, a significant increase was noted in the migration of the CP coating group vs. that of the TPS coating group. Upon the final observation at 6 months, the groups displayed on average a 0.74-mm migration. Most of the analyzed implants ceased migration within the first week post-surgery, but the CP coating demonstrated a higher and more prolonged migration compared to the TPS coating.


Subject(s)
Calcium Phosphates , Early Ambulation , Humans , Prostheses and Implants , Titanium/therapeutic use , Coated Materials, Biocompatible
2.
Open Access J Sports Med ; 14: 21-27, 2023.
Article in English | MEDLINE | ID: mdl-37163159

ABSTRACT

Purpose: Torn anterior cruciate ligaments in children are rare injuries. The incidence of concomitant avulsion fracture in the skeletally immature patient is high. Reports of arthroscopic reconstruction in the literature are sparse. Case Presentation: We present the case of a femoral avulsion fracture of the anterior cruciate ligament in a seven-year-old girl. The patient underwent arthroscopic refixation with DynacordTM Suture and Suture Button. At a follow-up of 8 weeks, the patient had free range of motion and a stable knee, with a negative Lachman- and Pivot-Shift-test in particular. Conclusion: Refixation of femoral avulsion fracture can lead to good results. Open physes and size of the knee should be taken into account. Anatomic reconstruction is compulsory to receive bone on bone healing.

3.
Eur Radiol Exp ; 7(1): 15, 2023 03 27.
Article in English | MEDLINE | ID: mdl-36967394

ABSTRACT

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) has the potential to provide superior image quality compared to energy-integrating detector computed tomography (EID-CT). We compared the two systems for elbow imaging in off-center arm positioning, 90° flexion, and cast fixation in a simulated post-trauma setting. METHODS: The institutional review board approved the study protocol. In a cadaver study, an olecranon fracture was artificially created in ten whole arm specimens. Two different scanning positions were evaluated: (a) arm overhead; and (b) arm on top of the abdomen of a whole-body phantom. The ultra-high resolution mode with three dose protocols and two reconstruction kernels was applied. Two blinded radiologists independently evaluated fracture and trabecular bone delineation. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and cortical sharpness measurements were performed. Cohen κ correlations, Mann-Whitney U and Wilcoxon signed rank tests were used. A p value lower than 0.05 was considered statistically significant. RESULTS: Dose-equivalent PCD-CT scans were rated better for fracture and trabecular bone evaluation (p < 0.001). SNR, CNR, and cortical sharpness were higher for all diagnostic (Br76) PCD-CT images (p < 0.001). The arm position had less effect on image quality in the PCD-CT compared to the EID-CT. The use of a sharp bone kernel (Br89) improved image quality ratings for PCD-CT. In the low-dose scan mode, PCD-CT resulted in more diagnostic scans (75%) compared to EID-CT (19%). CONCLUSIONS: PCD-CT provided superior objective and subjective image quality for fracture and trabecular bone structures delineation of the elbow compared to EID-CT in a typical post-trauma setting. KEY POINTS: • Photon-counting detector computed tomography (PCD-CT) preserved high image quality in elbow imaging with off-center positions. • PCD-CT was advantageous for bone evaluation in trauma elbows. • PCD-CT ultra-high-resolution mode and very sharp reconstruction kernels facilitated higher image quality.


Subject(s)
Elbow Joint , Humans , Elbow Joint/diagnostic imaging , Photons , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Cadaver
4.
J Orthop ; 20: 326-331, 2020.
Article in English | MEDLINE | ID: mdl-32641879

ABSTRACT

AIM: Short-stem total hip arthroplasty is designed to preserve proximal bone stock in case of eventual revision, potentially benefiting younger and more active patients. This prospective, single-center study assessed the safety and performance of the partially neck-sparing Nanos™ short-stem uncemented prosthesis at 24 months using clinical outcome scores and radiographic results. METHODS: Between April 2011 and February 2015, 52 subjects (mean age, 54.9 years) underwent total hip arthroplasty and were followed up at 3, 6, 12 and 24 months. The primary outcome was improvement in quality of life as measured by the Short-Form 36 Mental Component Score (SF-36 MCS). Secondary clinical outcomes included the Harris Hip Score, Hip Disability and Osteoarthritis Outcome Score, Postel Merle d'Aubigné-Score, Activity Level University of California, Los Angeles score, and Pain Visual Analogue Scale. Complications and radiographic images were also recorded at each follow-up. RESULTS: Mean SF-36 MCS score significantly improved from baseline to final follow up at 24 months (61.3 vs. 79.5, respectively; p < 0.001). All secondary clinical outcomes also showed significant improvement (p < 0.001) during this time period. Neutral stem positioning was achieved in 45 subjects (86.5%). Two subjects (3.8%) underwent revisions: one for a periprosthetic fracture unrelated to the study device and another due to a prosthetic joint infection. Intraoperatively, one fissure fracture of the acetabulum occurred. CONCLUSION: Total hip arthroplasty with the Nanos short-stem led to significant clinical improvements and a high subjective satisfaction rate at 24 months. Further follow-up will determine whether these effects are sustained in the long term.

SELECTION OF CITATIONS
SEARCH DETAIL
...