Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Arch Otorhinolaryngol ; 279(4): 1777-1785, 2022 Apr.
Article in English | MEDLINE | ID: mdl-33942123

ABSTRACT

BACKGROUND: Petrous bone pneumatization may be related to cerebrospinal fluid (CSF) leak secondary to vestibular schwannoma surgery. OBJECTIVE: To assess the association between petrous bone pneumatization and CSF leak in vestibular schwannoma surgery. METHODS: A retrospective study included 222 consecutive vestibular schwannoma patients treated via a retrosigmoid or translabyrinthine approach in a 17-year period in one University Hospital. Association of CSF leak and petrous bone pneumatization, as seen on CT scans, was assessed on ANOVA and Student's t or Chi-squared test in case of non-parametric distribution. RESULTS: One hundred and 75 resections were performed on a retrosigmoid approach and 47 on a translabyrinthine approach. Mean age was 53.6 ± 12.9 years. Mean follow-up was 5 years 6 months. Twenty-six patients (11.7%) showed CSF leak and 8 (3.6%) meningitis. Approach (p = 0.800), gender (p = 0.904), age (p = 0.234), body-mass index (p = 0.462), tumor stage (p = 0.681) and history of schwannoma surgery (p = 0.192) did not increase the risk of CSF leak. This risk was unrelated to mastoid pneumatization (p = 0.266). There was a highly significant correlation between internal acousticus meatus (IAM) posterior wall pneumatization and CSF leak after retrosigmoid surgery (p = 0.008). Eustachian tube packing in the translabyrinthine approach did not decrease risk of CSF leak (p = 0.571). CONCLUSION: Degree of petrous bone pneumatization was not significantly related to risk of CSF leak, but pneumatization of the posterior IAM wall increased this risk in retrosigmoid surgery. Eustachian tube packing in the translabyrinthine approach is not sufficient to prevent postoperative CSF leak. Both approaches had similar rates of CSF leaks, around 12%.


Subject(s)
Neuroma, Acoustic , Adult , Aged , Cerebrospinal Fluid Leak/etiology , Cerebrospinal Fluid Leak/prevention & control , Humans , Mastoid , Middle Aged , Neuroma, Acoustic/surgery , Petrous Bone/surgery , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Retrospective Studies
2.
Eur Arch Otorhinolaryngol ; 278(4): 965-975, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32588170

ABSTRACT

PURPOSE: To highlight the advantages of real time fluoroscopy guided electrode-array (EA) insertion (FGI) during cochlear implants surgery. METHODS: All surgical procedures were performed in a dedicated operating room equipped with a robotic C-arm cone beam device, allowing for intraoperative real time 2D FGI and postoperative 3D imaging. Only straight EAs were used. Patients were sorted out in three groups: ANAT, with anatomical concerns; HP, with residual hearing; NPR: patients with no particular reason for FGI. In all cases the angle of EA-insertion was measured. In the HP group pre and postoperative hearing were compared. The radiation delivered to the patient was recorded. RESULTS: Fifty-three cochlear implantation procedures were achieved under fluoroscopy in 50 patients from November 2015 to January 2020 (HP group: n = 10; ANAT group: n = 13; NPR group: n = 27). In the ANAT group, FGI proved to be helpful in 8 cases (61.5%), successfully guiding the surgeon during EA -insertion. On average, the angle of insertion was at 424° ± 55°. In the HP group, a controlled smooth EA-insertion was carried out in all cases but one. The targeted 360° angle of insertion was always reached. Hearing preservation was possible with an eventual average drop of 30 ± 1.5 dB. In the NPR group, FGI helped control the quality of insertion in all cases and appeared very informative in five (17.8%): one EA-misrouting, three stuck EAs, and one case with hidden electrodes out of the cochlea in revision surgery. Final 3D cone beam CT scan double-checked the EA position in all adults. The radiation dose was equivalent to a bit less than four digital subtract radiographs. CONCLUSION: The FGI is a very useful adjunct in cochlear implantation in all cases of expected surgical pitfalls, in patients with residual hearing, and even in case without preoperative particular reason, with low irradiation.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Cochlea/surgery , Electrodes, Implanted , Fluoroscopy , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...