Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phytochemistry ; 58(8): 1209-12, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11738409

ABSTRACT

The presence of betacyanin pigments and their isoforms has been detected in the fruit of Hylocereus polyrhizus, a vine cactus native to South America. Along with the known betanin and phyllocactin (6'-O-malonylbetanin), a new betacyanin was structurally elucidated as betanidin 5-O-[6'-O-(3"-hydroxy-3"-methyl-glutaryl)-beta-D-glucopyranoside] (proposed trivial name hylocerenin) by means of electrospray MS/MS, HPLC, and NMR techniques.


Subject(s)
Cactaceae/chemistry , Indoles/chemistry , Betacyanins , Fruit/chemistry , Indoles/isolation & purification , Mass Spectrometry
2.
Fresenius J Anal Chem ; 370(5): 624-8, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11496996

ABSTRACT

The capability of a second-generation Nu Instruments multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS) has been evaluated for precise and accurate isotope-ratio determinations of lead. Essentially the mass spectrometer is a double-focusing instrument of Nier-Johnson analyzer geometry equipped with a newly designed variable-dispersion ion optical device, enabling the measured ion beams to be focused into a fixed array of Faraday collectors and an ion-counting assembly. NIST SRM Pb 981, 982, and 983 isotopic standards were used. Addition of thallium to the lead standards and subsequent simultaneous measurement of the thallium and lead isotopes enabled correction for mass discrimination, by use of the exponential correction law and 205Tl/203Tl = 2.3875. Six measurements of SRM Pb-982 furnished the results 206Pb/204Pb = 36.7326(68), 207Pb/204Pb = 17.1543(30), 208Pb/204Pb = 36.7249(69), 207Pb/206Pb = 0.46700(1), and 208Pb/206Pb = 0.99979(2); the NIST-certified values were 36.738(37), 17.159(25), 36.744(50), 0.46707(20), and 1.00016(36), respectively. Direct isotope lead analysis in silicates can be performed without any chemical separation. NIST SRM 610 glass was dissolved and introduced into the MC-ICP-MS by means of a micro concentric nebulizer. The ratios observed were in excellent agreement with previously reported data obtained by TIMS and laser ablation MC-ICP-MS, despite the high Ca/Pb concentration ratio (200/1) and the presence of many other elements at levels comparable with that of lead. Approximately 0.2 microg lead are sufficient for isotope analysis with ratio uncertainties between 240 and 530 ppm.

SELECTION OF CITATIONS
SEARCH DETAIL
...