1.
PLoS One ; 12(7): e0179413, 2017.
Article in English | MEDLINE | ID: mdl-28742828

ABSTRACT

For accurate analysis of bone formation and resorption during fracture healing, correct registration of follow-up onto baseline image is required. A per-fragment approach could improve alignment compared to standard registration based on the whole fractured region. In this exploratory study, we tested the effect of fragment size and displacement on a per-fragment registration, and compared the results of this per-fragment registration to the results of the standard registration in two stable fractures and one unstable fracture. To test the effect of fragment size and displacement, high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of three unfractured radii were divided into subvolumes. Different displacements in x-, y, or z-direction or rotations around each axis were applied, and each subvolume was registered onto the initial volume to realign it. Next, registration of follow-up onto baseline scan was performed in two stable and one unstable fracture. After coarsely aligning the follow-up onto the baseline scan, a more accurate registration was performed of the whole fracture, i.e. the standard registration, and of each fracture fragment separately, i.e. per-fragment registration. Alignment was checked using overlay images showing baseline, follow-up and overlap between these scans, and by comparing correlation coefficients between the standard and per-fragment registration. Generally, subvolumes as small as 300 mm3 that were displaced up to 0.82 mm in x- or y-, or up to 1.64 mm in z-direction could be realigned correctly. For the fragments of all fractures, correlation coefficients were higher after per-fragment registration compared to standard registration. Most improvement was found in the unstable fracture and one fragment of the unstable fracture did not align correctly. This exploratory study showed that image registration of individual subvolumes, such as fracture fragments, is feasible in both stable and unstable fractures, and leads to better alignment of these fragments compared to an approach that is based on registration using the whole fractured region. This result is promising for additional analysis of bone formation and resorption in HR-pQCT studies on fracture healing.


Subject(s)
Fracture Healing , Imaging, Three-Dimensional/methods , Radius Fractures/diagnostic imaging , Radius/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Algorithms , Feasibility Studies , Humans , Middle Aged , Young Adult
2.
J Biomech ; 59: 43-49, 2017 07 05.
Article in English | MEDLINE | ID: mdl-28558915

ABSTRACT

Dual energy X-ray absorptiometry (DXA) is the standard for assessing fragility fracture risk using areal bone mineral density (aBMD), but only explains 60-70% of the variation in bone strength. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides 3D-measures of bone microarchitecture and volumetric bone mineral density (vBMD), but only at the wrist and ankle. Finite element (FE) models can estimate bone strength with 86-95% precision. The purpose of this study is to determine how well vBMD and FE bone strength at the wrist and ankle relate to fracture strength at the hip and spine, and to compare these relationships with DXA measured directly at those axial sites. Cadaveric samples (radius, tibia, femur and L4 vertebra) were compared within the same body. The radius and tibia specimens were assessed using HR-pQCT to determine vBMD and FE failure load. aBMD from DXA was measured at the femur and L4 vertebra. The femur and L4 vertebra specimens were biomechanically tested to determine failure load. aBMD measures of the axial skeletal sites strongly correlated with the biomechanical strength for the L4 vertebra (r=0.77) and proximal femur (r=0.89). The radius correlated significantly with biomechanical strength of the L4 vertebra for vBMD (r=0.85) and FE-derived strength (r=0.72), but not with femur strength. vBMD at the tibia correlated significantly with femoral biomechanical strength (r=0.74) and FE-estimated strength (r=0.83), and vertebral biomechanical strength for vBMD (r=0.97) and FE-estimated strength (r=0.91). The higher correlations at the tibia compared to radius are likely due to the tibia's weight-bearing function.


Subject(s)
Femur/physiology , Lumbar Vertebrae/physiology , Tibia/physiology , Absorptiometry, Photon , Aged , Aged, 80 and over , Bone Density , Female , Finite Element Analysis , Fractures, Bone/physiopathology , Humans , Male , Middle Aged , Radius/physiology , Tomography, X-Ray Computed , Weight-Bearing/physiology