Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Clin Invest ; 130(11): 5756-5764, 2020 11 02.
Article in English | MEDLINE | ID: mdl-32692731

ABSTRACT

BACKGROUNDInadequate tuberculosis (TB) diagnostics are a major hurdle in the reduction of disease burden, and accurate point-of-care tests (POCTs) are urgently needed. We assessed the diagnostic accuracy of Fujifilm SILVAMP TB lipoarabinomannan (FujiLAM) POCT for TB diagnosis in HIV-negative outpatients and compared it with Alere Determine TB LAM Ag (AlereLAM) POCT and a laboratory-based ultrasensitive electrochemiluminescence LAM research assay (EclLAM).METHODSIn this multicenter diagnostic test accuracy study, we recruited HIV-negative adults with symptoms suggestive of pulmonary TB presenting to outpatient health care centers in Peru and South Africa. Urine samples were tested using FujiLAM, AlereLAM, and EclLAM, and the diagnostic accuracy was assessed against a microbiological reference standard (MRS) and a composite reference standard.RESULTSThree hundred seventy-two HIV-negative participants were included and the prevalence of microbiologically confirmed TB was 30%. Compared with the MRS, the sensitivities of AlereLAM, FujiLAM, and EclLAM were 10.8% (95% confidence interval [CI] 6.3%-18.0%), 53.2% (95% CI 43.9%-62.1%), and 66.7% (95% CI 57.5%-74.7%), respectively. The specificities of AlereLAM, FujiLAM, and EclLAM were 92.3% (95% CI 88.5%-95.0%), 98.9% (95% CI 96.7%-99.6%), and 98.1% (95% CI 95.6%-99.2%), respectively. Positive likelihood ratios of AlereLAM, FujiLAM, and EclLAM were 1.4, 46.2, and 34.8, respectively, and positive predictive values were 37.5%, 95.2%, and 93.7%, respectively.CONCLUSIONCompared with AlereLAM, FujiLAM detected 5 times more patients with TB in HIV-negative participants, had a high positive predictive value, and has the potential to improve rapid diagnosis of TB at the point-of-care. EclLAM demonstrated that additional sensitivity gains are possible, which highlights LAM's potential as a biomarker. Additional research is required to assess FujiLAM's performance in prospective cohorts, its cost-effectiveness, and its impact in real-world clinical settings.FUNDINGGlobal Health Innovative Technology Fund, the UK Department for International Development, the Dutch Ministry of Foreign Affairs, the Bill and Melinda Gates Foundation, the Australian Department of Foreign Affairs and Trade, the German Federal Ministry of Education and Research through Kreditanstalt für Wiederaufbau, and the NIH and National Institute of Allergy and Infectious Diseases.


Subject(s)
HIV Seronegativity , Lipopolysaccharides/urine , Tuberculosis, Pulmonary , Adult , Female , Humans , Male , Middle Aged , Outpatients , Sensitivity and Specificity , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/urine
2.
PLoS One ; 14(4): e0215443, 2019.
Article in English | MEDLINE | ID: mdl-30998715

ABSTRACT

BACKGROUND: Tuberculosis (TB) infection was responsible for an estimated 1.3 million deaths in 2017. Better diagnostic tools are urgently needed. We sought to determine whether accurate TB antigen detection in blood or urine has the potential to meet the WHO target product profiles for detection of active TB. MATERIALS AND METHODS: We developed Electrochemiluminescence (ECL) immunoassays for Lipoarabinomannan (LAM) and ESAT-6 detection with detection limits in the pg/ml range and used them to compare the concentrations of the two antigens in the urine and serum of 81 HIV-negative and -positive individuals with presumptive TB enrolled across diverse geographic sites. RESULTS: LAM and ESAT-6 overall sensitivities in urine were 93% and 65% respectively. LAM and ESAT-6 overall sensitivities in serum were 55% and 46% respectively. Overall specificity was ≥97% in all assays. Sensitivities were higher in HIV-positive compared to HIV-negative patients for both antigens and both sample types, with signals roughly 10-fold higher on average in urine than in serum. The two antigens showed similar concentration ranges within the same sample type and correlated. CONCLUSIONS: LAM and ESAT-6 can be detected in the urine and serum of TB patients, regardless of the HIV status and further gains in clinical sensitivity may be achievable through assay and reagent optimization. Accuracy in urine was higher with current methods and has the potential to meet the WHO accuracy target if the findings can be transferred to a point-of-care TB test.


Subject(s)
Antigens, Bacterial , Bacterial Proteins , Electrochemical Techniques , Lipopolysaccharides , Luminescent Measurements , Mycobacterium tuberculosis , Tuberculosis , Adolescent , Adult , Antigens, Bacterial/blood , Antigens, Bacterial/urine , Bacterial Proteins/blood , Bacterial Proteins/urine , Female , Humans , Immunoassay , Lipopolysaccharides/blood , Lipopolysaccharides/urine , Male , Middle Aged , Retrospective Studies , Tuberculosis/blood , Tuberculosis/urine
3.
J Clin Microbiol ; 56(12)2018 12.
Article in English | MEDLINE | ID: mdl-30257899

ABSTRACT

The only currently commercialized point-of-care assay for tuberculosis (TB) that measures lipoarabinomannan (LAM) in urine (Alere LF-LAM) has insufficient sensitivity. We evaluated the potential of 100 novel monoclonal antibody pairs targeting a variety of LAM epitopes on a sensitive electrochemiluminescence platform to improve the diagnostic accuracy. In the screening, many antibody pairs showed high reactivity to purified LAM but performed poorly at detecting urinary LAM in clinical samples, suggesting differences in antigen structure and immunoreactivity of the different LAM sources. The 12 best antibody pairs from the screening were tested in a retrospective case-control study with urine samples from 75 adults with presumptive TB. The best antibody pair reached femtomolar analytical sensitivity for LAM detection and an overall clinical sensitivity of 93% (confidence interval [CI], 80% to 97%) and specificity of 97% (CI, 85% to 100%). Importantly, in HIV-negative subjects positive for TB by sputum smear microscopy, the test achieved a sensitivity of 80% (CI, 55% to 93%). This compares to an overall sensitivity of 33% (CI, 20% to 48%) of the Alere LF-LAM and a sensitivity of 13% (CI, 4% to 38%) in HIV-negative subjects in the same sample set. The capture antibody targets a unique 5-methylthio-d-xylofuranose (MTX)-dependent epitope in LAM that is specific to the Mycobacterium tuberculosis complex and shows no cross-reactivity with fast-growing mycobacteria or other bacteria. The present study provides evidence that improved assay methods and reagents lead to increased diagnostic accuracy. The results of this work have informed the development of a sensitive and specific novel LAM point-of-care assay with the aim to meet the WHO's performance target for TB diagnosis.


Subject(s)
Antigens, Bacterial/immunology , Diagnostic Tests, Routine/methods , Immunoassay , Lipopolysaccharides/immunology , Mycobacterium tuberculosis/isolation & purification , Tuberculosis/diagnosis , AIDS-Related Opportunistic Infections/diagnosis , AIDS-Related Opportunistic Infections/microbiology , Adult , Antibodies, Bacterial/immunology , Antibodies, Monoclonal/immunology , Antigens, Bacterial/chemistry , Case-Control Studies , Diagnostic Tests, Routine/standards , Epitopes/immunology , Female , Humans , Lipopolysaccharides/chemistry , Male , Middle Aged , Mycobacterium tuberculosis/immunology , Point-of-Care Systems , Retrospective Studies , Sensitivity and Specificity , Sputum/microbiology , Tuberculosis/microbiology , World Health Organization
SELECTION OF CITATIONS
SEARCH DETAIL
...