Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Radiology ; 207(3): 663-8, 1998 Jun.
Article in English | MEDLINE | ID: mdl-9609888

ABSTRACT

PURPOSE: To assess possible changes in quality control (QC) practices at mammography sites in the United States. MATERIALS AND METHODS: Mammography site surveys were conducted in 1990, 1992, and 1995 through the Colorado Mammography Advocacy Project (CMAP). Data from mammography sites applying for American College of Radiology (ACR) accreditation were collected between August 1987 and August 1993 through the ACR Mammography Accreditation Program. Data from both of these surveys were analyzed to assess temporal changes in mammography QC practices in the United States between 1987 and 1995. RESULTS: CMAP results indicated statistically significant improvement in medical physicist QC practices between 1990 and 1992 and in technologist QC practices between 1990 and 1995. Improvements in radiologic technologist QC practices coincided with increases in radiologic technologist continuing education in mammography. ACR results indicated statistically significant improvement in technologist QC practices between 1988 and 1992. CONCLUSION: There have been substantial improvements in QC practices at mammography sites in the United States during the past decade.


Subject(s)
Mammography/standards , Mammography/trends , Chi-Square Distribution , Colorado , Data Collection , Female , Humans , Mammography/statistics & numerical data , Phantoms, Imaging/standards , Phantoms, Imaging/statistics & numerical data , Quality Control , Sensitivity and Specificity , Surveys and Questionnaires , United States
2.
Radiol Clin North Am ; 33(6): 1041-57, 1995 Nov.
Article in English | MEDLINE | ID: mdl-7480654

ABSTRACT

This article describes the essential elements of an effective quality control program in mammography. Quality Control tests recently updated in the 1994 ACR Mammography Quality Control Manual, such as the darkroom fog and limiting spatial resolution tests, are described in detail. The article goes on to describe some common problems in mammography quality control, including processor sensitometry and image quality problems.


Subject(s)
Mammography/standards , Artifacts , Female , Health Physics/methods , Health Physics/standards , Humans , Mammography/instrumentation , Mammography/methods , Phantoms, Imaging/standards , Quality Control , Reproducibility of Results , Time Factors , X-Ray Film/standards , X-Ray Intensifying Screens/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...