ABSTRACT
OBJECTIVE: Hy-Result is the first software for self-interpretation of home blood pressure measurement results, taking into account both the recommended thresholds for normal values and patient characteristics. We compare the software-generated classification with the physician's evaluation. DESIGN METHOD: The primary assessment criterion was whether algorithm classification of the blood pressure (BP) status concurred with the physician's advice (blinded to the software's results) following a consultation (n=195 patients). Secondary assessment was the reliability of text messages. RESULTS: In the 58 untreated patients, the agreement between classification of the BP status generated by the software and the physician's classification was 87.9%. In the 137 treated patients, the agreement was 91.9%. The κ-test applied for all the patients was 0.81 (95% confidence interval: 0.73-0.89). After correction of errors identified in the algorithm during the study, agreement increased to 95.4% [κ=0.9 (95% confidence interval: 0.84-0.97)]. For 100% of the patients with comorbidities (n=46), specific text messages were generated, indicating that a physician might recommend a target BP lower than 135/85 mmHg. Specific text messages were also generated for 100% of the patients for whom global cardiovascular risks markedly exceeded norms. CONCLUSION: Classification by Hy-Result is at least as accurate as that of a specialist in current practice (http://www.hy-result.com).