1.
Microorganisms ; 7(11)2019 Oct 30.
Article in English | MEDLINE | ID: mdl-31671699

ABSTRACT

The parasite Cryptosporidium parvum represents a threat to livestock health and production, water quality and public health. Cattle are known to be significant reservoirs of C. parvum, but transmission routes are complex and recent studies have implicated the potential role of wildlife in parasite transmission to cattle and water sources. On the Orkney Isles, high densities of Greylag geese (Anser anser) cause widespread faecal contamination of cattle pastures, where cryptosporidiosis is known to be the main cause of neonatal calf diarrhoea and Cryptosporidium contamination frequently occurs in two reservoirs supplying Mainland Orkney's public water. This study aimed to determine the Cryptosporidium species and subtypes present in geese and calves co-grazing on four farms surrounding two reservoirs on Mainland Orkney. Results indicated a high level of C. parvum prevalence in calves, geese and water samples. gp60 analysis illustrated that higher genotypic diversity was present in the goose population compared with calves, but did not yield sequence results for any of the water samples. It can be concluded that the high levels of C. parvum evident in calves, geese and water samples tested represents a significant risk to water quality and public health.

2.
J Sci Med Sport ; 14(2): 100-5, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20832358

ABSTRACT

Determination of total haemoglobin mass (Hbmass) via carbon monoxide (CO) depends critically on repeatable measurement of percent carboxyhaemoglobin (%HbCO) in blood with a hemoximeter. The main aim of this study was to determine, for an OSM3 hemoximeter, the number of replicate measures as well as the theoretical change in percent carboxyhaemoglobin required to yield a random error of analysis (Analyser Error) of ≤1%. Before and after inhalation of CO, nine participants provided a total of 576 blood samples that were each analysed five times for percent carboxyhaemoglobin on one of three OSM3 hemoximeters; with approximately one-third of blood samples analysed on each OSM3. The Analyser Error was calculated for the first two (duplicate), first three (triplicate) and first four (quadruplicate) measures on each OSM3, as well as for all five measures (quintuplicates). Two methods of CO-rebreathing, a 2-min and 10-min procedure, were evaluated for Analyser Error. For duplicate analyses of blood, the Analyser Error for the 2-min method was 3.7, 4.0 and 5.0% for the three OSM3s when the percent carboxyhaemoglobin increased by two above resting values. With quintuplicate analyses of blood, the corresponding errors reduced to .8, .9 and 1.0% for the 2-min method when the percent carboxyhaemoglobin increased by 5.5 above resting values. In summary, to minimise the Analyser Error to ∼≤1% on an OSM3 hemoximeter, researchers should make ≥5 replicates of percent carboxyhaemoglobin and the volume of CO administered should be sufficient increase percent carboxyhaemoglobin by ≥5.5 above baseline levels.


Subject(s)
Carbon Monoxide/administration & dosage , Carboxyhemoglobin/analysis , Carboxyhemoglobin/standards , Doping in Sports , Oximetry/instrumentation , Oximetry/standards , Adult , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS