1.
Heart Rhythm ; 15(7): 1023-1030, 2018 07.
Article in English | MEDLINE | ID: mdl-29957188

ABSTRACT

BACKGROUND: Leadless cardiac pacemakers (LCPs) aim to mitigate lead- and pocket-related complications seen with transvenous pacemakers (TVPs). OBJECTIVE: The purpose of this study was to compare complications between the LCP cohort from the LEADLESS Pacemaker IDE Study (Leadless II) trial and a propensity score-matched real-world TVP cohort. METHODS: The multicenter LEADLESS II trial evaluated the safety and efficacy of the Nanostim LCP (Abbott, Abbott Park, IL) using structured follow-up, with serious adverse device effects independently adjudicated. TVP data were obtained from Truven Health MarketScan claims databases for patients implanted with single-chamber TVPs between April 1, 2010 and March 31, 2014 and more than 1 year of preimplant enrollment data. Comorbidities and complications were identified via International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes. Short-term (≤1 months) and mid-term (>1-18 months) complications were compared between the LCP cohort and a propensity score-matched subset of the TVP cohort. RESULTS: Among 718 patients with LCPs (mean age 75.6 ± 11.9 years; 62% men) and 1436 patients with TVPs (mean age 76.1 ± 12.3 years; 63% men), patients with LCPs experienced fewer complications (hazard ratio 0.44; 95% confidence interval 0.32-0.60; P < .001), including short-term (5.8% vs 9.4%; P = .01) and mid-term (0.56% vs 4.9%; P < .001) events. In the short-term time frame, patients with LCPs had more pericardial effusions (1.53% vs 0.35%; P = .005); similar rates of vascular events (1.11% vs 0.42%; P = .085), dislodgments (0.97% vs 1.39%; P = .54), and generator complications (0.70% vs 0.28%; P = .17); and no thoracic trauma compared to patients with TVPs (rate of thoracic trauma 3.27%). In short- and mid-term time frames, TVP events absent from the LCP group included lead-related, pocket-related, and infectious complications. CONCLUSION: Patients with LCPs experienced fewer overall short- and mid-term complications, including infectious and lead- and pocket-related events, but more pericardial effusions, which were uncommon but serious.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/adverse effects , Catheterization, Central Venous , Pacemaker, Artificial/adverse effects , Pericardial Effusion/etiology , Propensity Score , Aged , Arrhythmias, Cardiac/physiopathology , Equipment Design , Equipment Failure , Female , Follow-Up Studies , Humans , Male , Pericardial Effusion/diagnosis , Prognosis , Retrospective Studies , Time Factors
2.
N Engl J Med ; 373(12): 1125-35, 2015 Sep 17.
Article in English | MEDLINE | ID: mdl-26321198

ABSTRACT

BACKGROUND: Cardiac pacemakers are limited by device-related complications, notably infection and problems related to pacemaker leads. We studied a miniaturized, fully self-contained leadless pacemaker that is nonsurgically implanted in the right ventricle with the use of a catheter. METHODS: In this multicenter study, we implanted an active-fixation leadless cardiac pacemaker in patients who required permanent single-chamber ventricular pacing. The primary efficacy end point was both an acceptable pacing threshold (≤2.0 V at 0.4 msec) and an acceptable sensing amplitude (R wave ≥5.0 mV, or a value equal to or greater than the value at implantation) through 6 months. The primary safety end point was freedom from device-related serious adverse events through 6 months. In this ongoing study, the prespecified analysis of the primary end points was performed on data from the first 300 patients who completed 6 months of follow-up (primary cohort). The rates of the efficacy end point and safety end point were compared with performance goals (based on historical data) of 85% and 86%, respectively. Additional outcomes were assessed in all 526 patients who were enrolled as of June 2015 (the total cohort). RESULTS: The leadless pacemaker was successfully implanted in 504 of the 526 patients in the total cohort (95.8%). The intention-to-treat primary efficacy end point was met in 270 of the 300 patients in the primary cohort (90.0%; 95% confidence interval [CI], 86.0 to 93.2, P=0.007), and the primary safety end point was met in 280 of the 300 patients (93.3%; 95% CI, 89.9 to 95.9; P<0.001). At 6 months, device-related serious adverse events were observed in 6.7% of the patients; events included device dislodgement with percutaneous retrieval (in 1.7%), cardiac perforation (in 1.3%), and pacing-threshold elevation requiring percutaneous retrieval and device replacement (in 1.3%). CONCLUSIONS: The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients. Device-related serious adverse events occurred in approximately 1 in 15 patients. (Funded by St. Jude Medical; LEADLESS II ClinicalTrials.gov number, NCT02030418.).


Subject(s)
Arrhythmias, Cardiac/therapy , Pacemaker, Artificial , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/mortality , Electrocardiography, Ambulatory , Electrodes, Implanted , Equipment Design , Equipment Failure , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Middle Aged , Pacemaker, Artificial/adverse effects , Prospective Studies
11.
Am J Geriatr Cardiol ; 7(6): 46-54, 1998 Nov.
Article in English | MEDLINE | ID: mdl-11416480

ABSTRACT

The prevailing policy of treating people to their death and to resuscitate victims of cardiopulmonary arrest regardless of their health status is both inhumane and irrational. In this review we will explore how to change this wasteful high technology-driven, death-denying culture into one that accepts the eventuality of dying.