Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Interv Cardiol Clin ; 12(2): 237-244, 2023 04.
Article in English | MEDLINE | ID: mdl-36922064

ABSTRACT

Optical coherence tomography (OCT) is an imaging modality that is used in a significant number of interventional cardiology procedures. Key structural changes occurring within the vessel wall, including presence of neutrophils, macrophages, monocytes, and vascular smooth muscle cells, are below the resolution of clinical intracoronary OCT. To address this challenge, a new form of OCT with 1 to 2 µm resolution, termed micro-OCT (µOCT), has been developed. This review article summarizes the ability of µOCT technology to visualize coronary microstructures and discusses its clinical implications.


Subject(s)
Coronary Artery Disease , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods
2.
IEEE J Sel Top Quantum Electron ; 27(4): 7100412, 2021.
Article in English | MEDLINE | ID: mdl-33716587

ABSTRACT

Small form-factor sensors are widely used in minimally invasive intravascular diagnostic procedures. Manufacturing complexities associated with miniaturizing current fiber-optic probes, particularly for multi-parameter sensing, severely constrain their adoption outside of niche fields. It is especially challenging to rapidly prototype and iterate upon sensor designs to optimize performance for medical devices. In this work, a novel technique to construct a microscale extrinsic fiber-optic sensor with a confined air cavity and sub-micron geometric resolution is presented. The confined air cavity is enclosed between a 3 µm thick pressure-sensitive distal diaphragm and a proximal temperature-sensitive plano-convex microlens segment unresponsive to changes in external pressure. Simultaneous pressure and temperature measurements are possible through optical interrogation via phase-resolved low-coherence interferometry (LCI). Upon characterization in a simulated intravascular environment, we find these sensors capable of detecting pressure changes down to 0.11 mmHg (in the range of 760 to 1060 mmHg) and temperature changes of 0.036 °C (in the range 34 to 50 °C). By virtue of these sensitivity values suited to intravascular physiological monitoring, and the scope of design flexibility enabled by the precision-fabricated photoresist microstructure, it is envisaged that this technique will enable construction of a wide range of fiber-optic sensors for guiding minimally invasive medical procedures.

3.
J Biomed Opt ; 24(2): 1-4, 2019 02.
Article in English | MEDLINE | ID: mdl-30770678

ABSTRACT

Microscopic and mesoscale optical imaging techniques allow for three-dimensional (3-D) imaging of biological tissue across millimeter-scale regions, and imaging phantom models are invaluable for system characterization and clinical training. Phantom models that replicate complex 3-D geometries with both structural and molecular contrast, with resolution and lateral dimensions equivalent to those of imaging techniques (<20 µm), have proven elusive. We present a method for fabricating phantom models using a combination of two-photon polymerization (2PP) to print scaffolds, and microinjection of tailored tissue-mimicking materials to simulate healthy and diseased tissue. We provide a first demonstration of the capabilities of this method with intravascular optical coherence tomography, an imaging technique widely used in clinical practice. We describe the design, fabrication, and validation of three types of phantom models: a first with subresolution wires (5- to 34-µm diameter) arranged circumferentially, a second with a vessel side-branch, and a third containing a lipid inclusion within a vessel. Silicone hybrid materials and lipids, microinjected within a resin framework created with 2PP, served as tissue-mimicking materials that provided realistic optical scattering and absorption. We demonstrate that optical phantom models made with 2PP and microinjected tissue-mimicking materials can simulate complex anatomy and pathology with exquisite detail.


Subject(s)
Diagnostic Imaging/methods , Imaging, Three-Dimensional/methods , Optical Imaging/methods , Phantoms, Imaging , Biomimetics , Computer-Aided Design , Depth Perception , Humans , Lipids/chemistry , Models, Theoretical , Photons , Printing, Three-Dimensional , Refractometry , Silicones/chemistry , Tomography, Optical Coherence/methods
4.
Appl Phys Lett ; 110(22): 223701, 2017 May 29.
Article in English | MEDLINE | ID: mdl-28652642

ABSTRACT

All-optical ultrasound transducers are promising for imaging applications in minimally invasive surgery. In these devices, ultrasound is transmitted and received through laser modulation, and they can be readily miniaturized using optical fibers for light delivery. Here, we report optical ultrasound transmitters fabricated by electrospinning an absorbing polymer composite directly onto the end-face of optical fibers. The composite coating consisting of an aqueous dispersion of multi-walled carbon nanotubes (MWCNTs) in polyvinyl alcohol was directly electrospun onto the cleaved surface of a multimode optical fiber and subsequently dip-coated with polydimethylsiloxane (PDMS). This formed a uniform nanofibrous absorbing mesh over the optical fiber end-face wherein the constituent MWCNTs were aligned preferentially along individual nanofibers. Infiltration of the PDMS through this nanofibrous mesh onto the underlying substrate was observed and the resulting composites exhibited high optical absorption (>97%). Thickness control from 2.3 µm to 41.4 µm was obtained by varying the electrospinning time. Under laser excitation with 11 µJ pulse energy, ultrasound pressures of 1.59 MPa were achieved at 1.5 mm from the coatings. On comparing the electrospun ultrasound transmitters with a dip-coated reference fabricated using the same constituent materials and possessing identical optical absorption, a five-fold increase in the generated pressure and wider bandwidth was observed. The electrospun transmitters exhibited high optical absorption, good elastomer infiltration, and ultrasound generation capability in the range of pressures used for clinical pulse-echo imaging. All-optical ultrasound probes with such transmitters fabricated by electrospinning could be well-suited for incorporation into catheters and needles for diagnostics and therapeutic applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...