Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 15(20)2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37896311

ABSTRACT

MXene exhibits impressive characteristics, including flexibility, mechanical robustness, the capacity to cleanse liquids like water through MXene membranes, water-attracting nature, and effectiveness against bacteria. Additionally, bacterial cellulose (BC) exhibits remarkable qualities, including mechanical strength, water absorption, porosity, and biodegradability. The central hypothesis posits that the incorporation of both MXene and bacterial cellulose into the material will result in a remarkable synthesis of the attributes inherent to MXene and BC. In layered MXene/BC coatings, the presence of BC serves to separate the MXene layers and enhance the material's integrity through hydrogen bond interactions. This interaction contributes to achieving a high mechanical strength of this film. Introducing cellulose into one layer of multilayer MXene can increase the interlayer space and more efficient use of MXene. Composite materials utilizing MXene and BC have gained significant traction in sensor electronics due to the heightened sensitivity exhibited by these sensors compared to usual ones. Hydrogel wound healing bandages are also fabricated using composite materials based on MXene/BC. It is worth mentioning that MXene/BC composites are used to store energy in supercapacitors. And finally, MXene/BC-based composites have demonstrated high electromagnetic interference (EMI) shielding efficiency.

2.
Article in English | MEDLINE | ID: mdl-36892008

ABSTRACT

New conductive materials for tissue engineering are needed for the development of regenerative strategies for nervous, muscular, and heart tissues. Polycaprolactone (PCL) is used to obtain biocompatible and biodegradable nanofiber scaffolds by electrospinning. MXenes, a large class of biocompatible 2D nanomaterials, can make polymer scaffolds conductive and hydrophilic. However, an understanding of how their physical properties affect potential biomedical applications is still lacking. We immobilized Ti3C2Tx MXene in several layers on the electrospun PCL membranes and used positron annihilation analysis combined with other techniques to elucidate the defect structure and porosity of nanofiber scaffolds. The polymer base was characterized by the presence of nanopores. The MXene surface layers had abundant vacancies at temperatures of 305-355 K, and a voltage resonance at 8 × 104 Hz with the relaxation time of 6.5 × 106 s was found in the 20-355 K temperature interval. The appearance of a long-lived component of the positron lifetime was observed, which was dependent on the annealing temperature. The study of conductivity of the composite scaffolds in a wide temperature range, including its inductive and capacity components, showed the possibility of the use of MXene-coated PCL membranes as conductive biomaterials. The electronic structure of MXene and the defects formed in its layers were correlated with the biological properties of the scaffolds in vitro and in bacterial adhesion tests. Double and triple MXene coatings formed an appropriate environment for cell attachment and proliferation with mild antibacterial effects. A combination of structural, chemical, electrical, and biological properties of the PCL-MXene composite demonstrated its advantage over the existing conductive scaffolds for tissue engineering.

3.
ACS Appl Mater Interfaces ; 13(14): 16928-16938, 2021 Apr 14.
Article in English | MEDLINE | ID: mdl-33819009

ABSTRACT

A combination of coating deposition and consequent ion implantation could be beneficial in wear-resistant antifriction surface design and modification. In the present paper, the effects of low-energy 60 keV Si-ion implantation on multinanolayered CrN/ZrN grown on a stainless-steel substrate have been investigated. Complementary experimental (X-ray diffraction, high-resolution transmission electron microscopy, energy-dispersive spectroscopy, secondary ion mass spectrometry) and theoretical (first-principles) methods have been employed to investigate the structure, phase, and composition under a 1 × 10-17 cm-2 irradiation dose. This study has revealed a moderate radiation-tolerance of the CrN/ZrN system, with a 26 nm bilayer period, where the effective ion range after irradiation was below 110 nm. Within the ion range, a decrease in composition homogeneity and structure crystallinity has been found. Si negative ions have been distributed asymmetrically with peak concentrations (10 and 6%) occupying the interfaces between the CrN and ZrN layers. First-principles investigations of the CrN/ZrN(001) heterostructures were carried out to validate the experimental results, which showed that the alignment of Si-rich interfaces closer to chromium layers is a consequence of the lower substitution energy of CrN rather than ZrN. Thus, strong Si-Cr bindings and difference in displacement energies of ZrN and CrN have been attributed as the main factors in Si-rich interface formation. The pin-on-ball tribological test results have exposed the enhancement in wear resistance and the friction coefficient of nanoscale coating via amorphous Si particles descending from interfacial areas and acting as a third-body.

4.
ACS Appl Mater Interfaces ; 11(51): 48540-48550, 2019 Dec 26.
Article in English | MEDLINE | ID: mdl-31647641

ABSTRACT

A multilayered nanocomposite designed for biomedical applications based on (TiAlSiY)N/CrN coating implanted by heavy Au- ions is studied. Ion irradiation produced formation in the upper-surface of local amorphous clusters. The obtained composite system was characterized by SEM-EDS, RBS, SIMS, HRTEM, STEM, and nanoindentation mechanical tests, inspecting microstructure, phase state, elemental composition and surface defectiveness. The range of ion impact with correlation to TRIM simulations amounted to 23.5 nm with visible dislocations and interstitial loops indicating the nanopores' creation up/lengthways to the interface boundary. Mechanical parameters remain stable with a slight decrease (less than 2%) in hardness along with an increase in ductility. The antibacterial effect was evaluated in vitro by agar-diffusion and time-kill (72 h) assessments to define both cell-killing mechanisms: dry surface-contact and cytotoxic golden ions-release into moist environment. The identified antibacterial activity within implantation was 2-2.5 times higher due to inhibition zone diameter and antibacterial rate increase. The Au- implanted composite exhibits excellent defense against Gram-negative and Gram-positive bacteria without appreciable surface contamination. Possible biophysical and chemical mechanisms of microorganisms' disruption and annihilation were proposed and analyzed. The present study shows that produced composite has large potential for use in biomedical areas.

SELECTION OF CITATIONS
SEARCH DETAIL
...