Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Musculoskelet Disord ; 12: 142, 2011 Jun 29.
Article in English | MEDLINE | ID: mdl-21714916

ABSTRACT

BACKGROUND: Low-contact-stress (LCS) mobile-bearing total knee arthroplasty (TKA) (Johnson & Johnson, New Brunswick, NJ; previously: DePuy, Warsawa, USA) provides excellent functional results and wear rates in long-term follow-up analyses. Radiological analysis shows radiolucent lines (RLL) appearing immediately or two years after primary implantation, indicative of poor seat. Investigations proved RLL to be more frequent in uncemented TKA, resulting in a consensus to cement the tibial plateau, but their association with clinical findings and patients discomfort and knee pain is still unknown. METHODS: 553 patients with 566 low-contact-stress (LCS) total knee prostheses were screened for continuous moderate knee pain. We compared tibial stress shielding classified by Ewald in patients suffering from pain with a matched, pain-free control group on blinded X-rays. We hypothesized a positive correlation between pain and radiolucency and higher frequency of such radiolucent lines in the most medial and most lateral zones of the tibial plateau. RESULTS: Twenty-eight patients suffered from knee pain in total. Radiolucencies were detected in 27 of these cases and in six out of 28 matched controls without knee pain. We could demonstrate a significant correlation of knee pain and radiolucencies, which appeared significantly more frequently in the outermost zones of the tibial plateau. CONCLUSION: Our findings suggest that radiolucent lines, representing poor implant seat, about the tibial plateau are associated with knee pain in LCS patients. Radiolucencies are observed more often in noncemented LCS, and cementing the tibial plateau might improve implant seat and reduce both radiolucent lines and associated knee pain.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Prosthesis Failure/etiology , Adult , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Case-Control Studies , Female , Follow-Up Studies , Humans , Linear Models , Male , Middle Aged , Multivariate Analysis , Osteoarthritis, Knee/physiopathology , Prosthesis Failure/adverse effects , Radiography , Retrospective Studies , Sex Factors , Single-Blind Method , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...