Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ultramicroscopy ; 171: 158-165, 2016 12.
Article in English | MEDLINE | ID: mdl-27690346

ABSTRACT

Kelvin Probe Force Microscopy (KPFM) on samples with rough surface topography can be hindered by topography correlated artifacts. We show that, with the proper experimental configuration and using homogeneously metal coated probes, we are able to obtain amplitude modulation (AM) KPFM results on a gold coated sample with rough topography that are free from such artifacts. By inducing tip inhomogeneity through contact with the sample, clear potential variations appear in the KPFM image, which correlate with the surface topography and, thus, are probe induced artifacts. We find that switching to frequency modulation (FM) KPFM with such altered probes does not remove these artifacts. We also find that the induced tip inhomogeneity causes a lift height dependence of the KPFM measurement, which can therefore be used as a check for the presence of probe induced topography correlated artifacts. We attribute the observed effects to a work function difference between the tip and the rest of the probe and describe a model for such inhomogeneous probes that predicts lift height dependence and topography correlated artifacts for both AM and FM-KPFM methods. This work demonstrates that using a probe with a homogeneous work function and preventing tip changes is essential for KPFM on non-flat samples. From the three investigated probe coatings, PtIr, Au and TiN, the latter appears to be the most suitable, because of its better resistance against coating damage.

2.
Rev Sci Instrum ; 85(4): 046111, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24784689

ABSTRACT

In Kelvin Probe Force Microscopy (KPFM) electronic crosstalk can occur between the excitation signal and probe deflection signal. Here, we demonstrate how a small modification to our commercial instrument enables us to literally switch the crosstalk on and off. We study in detail the effect of crosstalk on open-loop KPFM and compare with closed-loop KPFM. We measure the pure crosstalk signal and verify that we can correct for it in the data-processing required for open-loop KPFM. We also demonstrate that open-loop KPFM results are independent of the frequency and amplitude of the excitation signal, provided that the influence of crosstalk has been eliminated.

3.
Nano Lett ; 11(4): 1623-9, 2011 Apr 13.
Article in English | MEDLINE | ID: mdl-21348493

ABSTRACT

Multiple exciton generation (MEG) in PbSe quantum dots (QDs), PbSe(x)S(1-x) alloy QDs, PbSe/PbS core/shell QDs, and PbSe/PbSe(y)S(1-y) core/alloy-shell QDs was studied with time-resolved optical pump and probe spectroscopy. The optical absorption exhibits a red-shift upon the introduction of a shell around a PbSe core, which increases with the thickness of the shell. According to electronic structure calculations this can be attributed to charge delocalization into the shell. Remarkably, the measured quantum yield of MEG, the hot exciton cooling rate, and the Auger recombination rate of biexcitons are similar for pure PbSe QDs and core/shell QDs with the same core size and varying shell thickness. The higher density of states in the alloy and core/shell QDs provide a faster exciton cooling channel that likely competes with the fast MEG process due to a higher biexciton density of states. Calculations reveal only a minor asymmetric delocalization of holes and electrons over the entire core/shell volume, which may partially explain why the Auger recombination rate does not depend on the presence of a shell.


Subject(s)
Lead/chemistry , Quantum Dots , Selenium Compounds/chemistry , Equipment Design , Equipment Failure Analysis , Light , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...