Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Eur Radiol ; 33(1): 523-534, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35895119

ABSTRACT

OBJECTIVES: To investigate the effect of saline-diluted gadoxetic acid, done for arterial-phase (AP) artifact reduction, on signal intensity (SI), and hence focal lesion conspicuity on MR imaging. METHODS: We retrospectively examined 112 patients who each had at least two serial gadoxetic acid-enhanced liver MRIs performed at 1 ml/s, first with non-diluted (ND), then with 1:1 saline-diluted (D) contrast. Two blinded readers independently analyzed the artifacts and graded dynamic images using a 5-point scale. The absolute SI of liver parenchyma, focal liver lesions (if present), aorta, and portal vein at the level of the celiac trunk and the SI of the paraspinal muscle were measured in all phases. The signal-to-norm (SINorm) of the vascular structures, hepatic parenchyma and focal lesions, and the contrast-to-norm (CNorm) of focal liver lesions were calculated. RESULTS: AP artifacts were significantly reduced with dilution. Mean absolute contrast-enhanced liver SI was significantly higher on the D exams compared to the ND exams. Likewise, SINorm of liver parenchyma was significantly higher in all contrast-enhanced phases except transitional phase on the D exams. SINorm values in the AP for the aorta and in the PVP for portal vein were significantly higher on the diluted exams. The CNorm was not significantly different between ND and D exams for lesions in any imaging phase. The interclass correlation coefficient was excellent (0.89). CONCLUSION: Gadoxetic acid dilution injected at 1ml/s produces images with significantly fewer AP artifacts but no significant loss in SINorm or CNorm compared to standard non-diluted images. KEY POINTS: • Diluted gadoxetic acid at slow injection (1 ml/s) yielded images with higher SINorm of the liver parenchyma and preserved CNorm for focal liver lesions. • Gadoxetic acid-enhanced MRI injected at 1 ml/s is associated with arterial-phase (AP) artifacts in 31% of exams, which may degrade image quality and limits focal liver lesion detection. • Saline dilution of gadoxetic acid 1:1 combined with a slow injection rate of 1 ml/s significantly reduced AP artifacts from 31 to 9% and non-diagnostic AP artifacts from 16 to 1%.


Subject(s)
Artifacts , Liver Neoplasms , Humans , Retrospective Studies , Contrast Media/pharmacology , Gadolinium DTPA/pharmacology , Magnetic Resonance Imaging/methods , Liver Neoplasms/pathology , Hepatic Artery/pathology , Liver/diagnostic imaging , Liver/pathology , Saline Solution
2.
Eur J Radiol ; 147: 110145, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35007983

ABSTRACT

PURPOSE: To investigate the effects of a rectal preparation regimen, that consisted of a rectal cleansing enema and an endorectal gel filling protocol, on prostate imaging quality (PI-QUAL). METHODS: Multiparametric MRI (mpMRI) was performed in 150 consecutive patients divided into two groups of 75 patients. One group received a rectal preparation with a cleansing enema and endorectal gel filling (median age 65.3 years, median PSA level 6 ng/ml). The other patient group did not receive such a preparation (median age 64 years, median PSA level 6 ng/ml). Two uroradiologists independently rated general image quality and lesion visibility on diffusion-weighted imaging (DWI), T2-weighted (T2w), and dynamic contrast-enhanced (DCE) images using a five-point ordinal scale. In addition, two uroradiologists assigned PI-QUAL scores, using the dedicated scoring sheet. Data sets were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/ area under the curve (AUC) analysis. RESULTS: VGC revealed significantly better general image quality for DWI (AUC R1 0.708 (0.628-0.779 CI, p < 0.001; AUC R2 0.687 (0.606-0.760 CI, p < 0.001) and lesion visibility for both readers (AUC R1 0.729 (0.607-0.831 CI, p < 0.001); AUC R2 0.714 (0.590-0.818CI, p < 0.001) in the preparation group. For T2w imaging, rectal preparation resulted in significantly better lesion visibility for both readers (R1 0.663 (0.537-0.774 CI, p = 0.014; R2 0.663 (0.537-0.774 CI, p = 0.014)). Averaged PI-QUAL scores were significantly improved with rectal preparation (AUC R3/R4 0.667, CI 0.581-0.754, p < 0.001). CONCLUSION: Rectal preparation significantly improved prostate imaging quality (PI-QUAL) and lesion visibility. Hence, a rectal preparation regimen consisting of a rectal cleansing enema and an endorectal gel filling could be considered.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms , Aged , Diffusion Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Prostate , Retrospective Studies
3.
PLoS One ; 14(12): e0225673, 2019.
Article in English | MEDLINE | ID: mdl-31856177

ABSTRACT

PURPOSE: Advanced forms of prostate cancer (PCa) radiotherapy with either external beam therapy or brachytherapy delivery techniques aim for a focal boost and thus require accurate lesion localization and lesion segmentation for subsequent treatment planning. This study prospectively evaluated dynamic contrast-enhanced computed tomography (DCE-CT) for the detection of prostate cancer lesions in the peripheral zone (PZ) using qualitative and quantitative image analysis compared to multiparametric magnet resonance imaging (mpMRI) of the prostate. METHODS: With local ethics committee approval, 14 patients (mean age, 67 years; range, 57-78 years; PSA, mean 8.1 ng/ml; range, 3.5-26.0) underwent DCE-CT, as well as mpMRI of the prostate, including standard T2, diffusion-weighted imaging (DWI), and DCE-MRI sequences followed by transrectal in-bore MRI-guided prostate biopsy. Maximum intensity projections (MIP) and DCE-CT perfusion parameters (CTP) were compared between healthy and malignant tissue. Two radiologists independently rated image quality and the tumor lesion delineation quality of PCa using a five-point ordinal scale. MIP and CTP were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: The PCa detection rate ranged between 57 to 79% for the two readers for DCE-CT and was 92% for DCE-MRI. DCE-CT perfusion parameters in PCa tissue in the PZ were significantly different compared to regular prostate tissue and benign lesions. Image quality and lesion visibility were comparable between DCE-CT and DCE-MRI (VGC: AUC 0.612 and 0.651, p>0.05). CONCLUSION: Our preliminary results suggest that it is feasible to use DCE-CT for identification and visualization, and subsequent segmentation for focal radiotherapy approaches to PCa.


Subject(s)
Four-Dimensional Computed Tomography/methods , Perfusion Imaging/methods , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Aged , Biopsy, Large-Core Needle , Contrast Media/administration & dosage , Diffusion Magnetic Resonance Imaging , Feasibility Studies , Humans , Image-Guided Biopsy , Male , Middle Aged , Neoplasm Grading , Proof of Concept Study , Prospective Studies , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiation Dosage
4.
PLoS One ; 14(9): e0222783, 2019.
Article in English | MEDLINE | ID: mdl-31545834

ABSTRACT

INTRODUCTION: The shoulder, a very complex joint, offers a wide range of pathologies. Intraarticular abnormalities and rotator cuff injuries are mainly assessed and diagnosed by magnetic resonance arthrography (MRA). In contrast to this well-established gold standard, high-resolution ultrasound (US) offers an additional easy and excellent modality to assess the shoulder joint. Therefore, the purpose of this study was to evaluate in which anatomic structures and pathologies comparable results of US and MRA could be achieved. MATERIALS AND METHODS: In this IRB-approved prospective study 67 patients with clinically suspected labral lesions, rotator cuff rupture, or injury of the long head of the biceps (LHB) tendon were enrolled. Each participant was examined with high resolution US, and directly followed by MRA at 3 Tesla with a standard sequence protocol. To evaluate the agreement of the diagnostic performance between US and MRA a weighted kappa statistic was used. RESULTS: Both of the investigated modalities yielded a moderate to almost perfect agreement in assessing a wide range of shoulder joint pathologies. For the rotator cuff, consistency was found in 71.64% for the supraspinatus tendon, in 95.52% for the infraspinatus tendon, in 83.58% for the subscapularis tendon, and in 98.51% for the teres minor tendon. The diagnostic accuracy between both modalities was 80.60% for the LHB tendon, 77.61% for the posterior labroligamentous complex, 83.58% for the acromioclavicular joint, and 91.04% for the assessment of osseous irregularities and impaction fractures. CONCLUSIONS: High resolution US is a reliable imaging modality for the rotator cuff, the LHB tendon, and the acromioclavicular joint, so for these structures we recommend a preference for US over MRA based on its diagnostic accuracy, comfortability, cost effectiveness, and availability. If the diagnosis remains elusive, for all other intraarticular structures we recommend MRA for further diagnostic assessment.


Subject(s)
Arthrography/methods , Athletic Injuries/diagnostic imaging , Magnetic Resonance Imaging/methods , Rotator Cuff Injuries/diagnostic imaging , Shoulder Injuries/diagnostic imaging , Ultrasonography/methods , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Rotator Cuff/diagnostic imaging , Shoulder Joint/diagnostic imaging , Young Adult
5.
Eur J Radiol ; 116: 27-33, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31153570

ABSTRACT

BACKGROUND: Dynamic contrast enhanced (DCE) MRI parameters are potential biomarkers to characterise tumour vasculature and distinguish it from the non-cancerous blood vessel system within the prostate. However, the inevitable presence of intra- and inter-observer variabilities is challenging in this context. Additionally, pre-contrast T1-time correction is a prerequisite to gain quantitative DCE parameters in the first place. The current study investigated the effect of individualized T1-time correction on intra- and inter-reader variability for quantitative DCE-parameters in prostatic lesions. METHODS: In this IRB-approved retrospective study, two experienced radiologists assessed DCE parameters using individually measured (A) and fixed (B) T1-times twice with a time difference of three weeks. The dataset consisted of 35 MRI-guided biopsy-proven prostate cancer lesions. Limits of agreement (LoA) and coefficients of variability (CoV) were calculated to assess intra- and inter-reader variabilities of the parameters. RESULTS: With exception of kep, for all DCE parameters both intra- and inter-reader CoV were smaller in B compared to A. Absolute kep values were largely insensitive to T1-time correction induced bias. The mean intra-reader CoVs [5%, 95% percentile] (over all four DCE parameters and both readers) were 6.7% [0.5%, 15.1%] in A and 3.9% [0.2%, 11.0%] in B. The inter-reader CoVs were 9.0% [0.6%, 25.8%] (A) and 7.0% [0.3%, 25.4%] (B). CONCLUSIONS: T1-time correction has a significant influence on the intra- and inter-reader variability. By applying individually measured T1-time correction, both intra- and inter-observer variability were found to increase. Out of all investigated DCE parameters, kep is the most robust to this investigated bias.


Subject(s)
Contrast Media , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Aged , Humans , Image-Guided Biopsy , Male , Observer Variation , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/pathology , Reproducibility of Results , Retrospective Studies
6.
J Magn Reson Imaging ; 50(6): 1754-1761, 2019 12.
Article in English | MEDLINE | ID: mdl-31136044

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) is an MRI technique with the potential to serve as an unenhanced breast cancer detection tool. Synthetic b-values produce images with high diffusion weighting to suppress residual background signal, while avoiding additional measurement times and reducing artifacts. PURPOSE: To compare acquired DWI images (at b = 850 s/mm2 ) and different synthetic b-values (at b = 1000-2000 s/mm2 ) in terms of lesion visibility, image quality, and tumor-to-tissue contrast in patients with malignant breast tumors. STUDY TYPE: Retrospective. POPULATION: Fifty-three females with malignant breast lesions. FIELD STRENGTH/SEQUENCE: T2 w, DWI EPI with STIR fat-suppression, and dynamic contrast-enhanced T1 w at 3T. ASSESSMENT: From acquired images using b-values of 50 and 850 s/mm2 , synthetic images were calculated at b = 1000, 1200, 1400, 1600, 1800, and 2000 s/mm2 . Four readers independently rated image quality, lesion visibility, preferred b-value, as well as the lowest and highest b-value, over the range of b-values tested, to provide a diagnostic image. STATISTICAL TESTS: Medians and mean ranks were calculated and compared using the Friedman test and Wilcoxon signed-rank test. Reproducibility was analyzed by intraclass correlation (ICC), Fleiss, and Cohen's κ. RESULTS: Relative signal-to-noise and contrast-to-noise ratios decreased with increasing b-values, while the signal-intensity ratio between tumor and tissue increased significantly (P < 0.001). Intermediate b-values (1200-1800 s/mm2 ) were rated best concerning image quality and lesion visibility; the preferred b-value mostly lay at 1200-1600 s/mm2 . Lowest and highest acceptable b-values were 850 s/mm2 and 2000 s/mm2 . Interreader agreement was moderate to high concerning image quality (ICC: 0.50-0.67) and lesion visibility (0.70-0.93), but poor concerning preferred and acceptable b-values (κ = 0.032-0.446). DATA CONCLUSION: Synthetically increased b-values may be a way to improve tumor-to-tissue contrast, lesion visibility, and image quality of breast DWI, while avoiding the disadvantages of performing DWI at very high b-values. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1754-1761.


Subject(s)
Breast Neoplasms/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Artifacts , Breast/diagnostic imaging , Female , Humans , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Signal-To-Noise Ratio
7.
Invest Radiol ; 53(12): 736-741, 2018 12.
Article in English | MEDLINE | ID: mdl-29985792

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the potential of diffusion-weighted imaging-derived apparent diffusion coefficient (ADC) measurements to obviate unnecessary biopsies in multiparametric MRI-detected PI-RADS 4 and 5 lesions. MATERIALS AND METHODS: This retrospective, institutional review board-approved study investigated 101 PI-RADS 4 and 5 prostate lesions (52 malignant, 49 benign) verified by in-bore MRI-guided biopsy in 101 men (mean age, 62.8 years). Two readers, who were not aware of the biopsy results independently and repeatedly measured minimum, mean, and maximum ADC from diffusion-weighted imaging measurements (in line with PI-RADS v2 recommendations) using a 2-dimensional region of interest drawn around the biopsied lesions. Diagnostic performance was evaluated using receiver operating characteristic statistics and reproducibility statistics were calculated. RESULTS: The best diagnostic performance (overall area under the receiver operating characteristic curve [AUC] R1: 0.801; R2: 0.796 peripheral zone AUC R1:0.814, R2: 0.805; transitional zone AUC R1:0.786, R2:0.779) and the tightest limits of interreader agreement (-8.6% to 9.9%) were found in minimum ADC values. Rule-in and rule-out thresholds for diagnosis of prostate cancer were identified, demonstrating a potential to avoid unnecessary biopsies in 32.7% (16/49). CONCLUSIONS: Quantitative ADC measurement in multiparametric MRI-detected PI-RADS 4 and 5 lesions has the potential to avoid unnecessary MRI-guided biopsies in up to 33%.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiology Information Systems , Unnecessary Procedures , Aged , Aged, 80 and over , Contrast Media , Humans , Image Enhancement/methods , Image-Guided Biopsy , Magnetic Resonance Imaging , Male , Middle Aged , Prostate/diagnostic imaging , Prostate/pathology , ROC Curve , Radiology, Interventional , Reproducibility of Results , Retrospective Studies
8.
Eur Radiol ; 28(5): 1919-1928, 2018 May.
Article in English | MEDLINE | ID: mdl-29168006

ABSTRACT

PURPOSE: To investigate prevalence, malignancy rates, imaging features, and follow-up intervals for probably benign (BI-RADS 3) lesions on breast magnetic resonance imaging (MRI). METHODS: A systematic database-review of articles published through 22/06/2016 was performed. Eligible studies reported BI-RADS 3 lesions on breast MRI. Two independent reviewers performed a literature review and data extraction. Data collection included study characteristics, number/type of BI-RADS 3 lesions, final diagnosis (histopathology and/or follow-up). Sources of bias (QUADAS-2) were assessed. Meta-analysis included data-pooling, heterogeneity testing, and meta-regression. RESULTS: Fifteen studies were included. Prevalence was reported in 11 studies (range: 1.2-24.3%). Malignancy rates ranged between 0.5-10.1% (pooled 61/2814, 1.6%, 95%-CI:0.9-2.3% (random-effects-model), I2=53%, P=0.007). In a subgroup of 11 studies (2183 lesions), highest malignancy rates were observed in non-mass lesions (pooled 25/714, 2.3%, 95%-CI:0.8-3.9%, I2=52%, P=0.021) followed by mass lesions (pooled 15/771, 1.5%, 95%-CI:0.7-2.4%, I2=0%, P=0.929), and foci (pooled 10/698, 1%, 95%-CI:0.3-1.7%, I2=0%, P=0.800). There was non-significant negative association between prevalence and malignancy rates (P=0.077). Malignant lesions were diagnosed at all follow-up time points. CONCLUSION: While prevalence of MRI BI-RADS 3 lesions was strongly heterogeneous, pooled malignancy rates met BI-RADS benchmarks (<2%). Malignancy rates varied, exceeding 2% in non-mass lesions. Twenty-four-month surveillance is required to detect all malignant lesions. KEY POINTS: • Probably benign (BI-RADS 3) lesions showed a pooled malignancy-rate of 1.6% (95%-CI:0.9-2.3%). • Malignancy rates differ and are highest in non-mass lesions (2.3%, 95%-CI:0.8-3.9%). • The prevalence of BI-RADS 3 lesions on breast MRI ranged from 1.2-24.3%. • Malignant lesions were diagnosed at follow-up time points up to 24 months.


Subject(s)
Breast Neoplasms/diagnosis , Magnetic Resonance Imaging/methods , Breast Neoplasms/epidemiology , Diagnosis, Differential , Female , Global Health , Humans , Prevalence
9.
Eur Radiol ; 28(4): 1634-1641, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29134351

ABSTRACT

OBJECTIVES: To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. METHODS: This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). CONCLUSIONS: Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. KEY POINTS: • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.


Subject(s)
Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Prostate/pathology , Prostatic Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Area Under Curve , Humans , Male , Middle Aged , Prospective Studies , ROC Curve
10.
Phys Med Biol ; 62(19): 7833-7854, 2017 Sep 21.
Article in English | MEDLINE | ID: mdl-28837046

ABSTRACT

The role of multi-parametric (mp)MRI in the diagnosis and treatment of prostate cancer has increased considerably. An alternative to visual inspection of mpMRI is the evaluation using histogram-based (first order statistics) parameters and textural features (second order statistics). The aims of the present work were to investigate the relationship between benign and malignant sub-volumes of the prostate and textures obtained from mpMR images. The performance of tumor prediction was investigated based on the combination of histogram-based and textural parameters. Subsequently, the relative importance of mpMR images was assessed and the benefit of additional imaging analyzed. Finally, sub-structures based on the PI-RADS classification were investigated as potential regions to automatically detect maligned lesions. Twenty-five patients who received mpMRI prior to radical prostatectomy were included in the study. The imaging protocol included T2, DWI, and DCE. Delineation of tumor regions was performed based on pathological information. First and second order statistics were derived from each structure and for all image modalities. The resulting data were processed with multivariate analysis, using PCA (principal component analysis) and OPLS-DA (orthogonal partial least squares discriminant analysis) for separation of malignant and healthy tissue. PCA showed a clear difference between tumor and healthy regions in the peripheral zone for all investigated images. The predictive ability of the OPLS-DA models increased for all image modalities when first and second order statistics were combined. The predictive value reached a plateau after adding ADC and T2, and did not increase further with the addition of other image information. The present study indicates a distinct difference in the signatures between malign and benign prostate tissue. This is an absolute prerequisite for automatic tumor segmentation, but only the first step in that direction. For the specific identified signature, DCE did not add complementary information to T2 and ADC maps.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/pathology , Aged , Humans , Male , Middle Aged , Principal Component Analysis , Prostatectomy , Prostatic Neoplasms/surgery
11.
PLoS One ; 12(7): e0180790, 2017.
Article in English | MEDLINE | ID: mdl-28719629

ABSTRACT

BACKGROUND: The aim of this study was to evaluate whether MP [11C]Acetate PET-MRI enables an accurate differentiation of benign and malignant prostate tumors as well as local and distant staging. MATERIALS AND METHODS: Fifty-six consecutive patients fulfilling the following criteria were included in this IRB-approved prospective study: elevated PSA levels or suspicious findings at digital rectal examination or TRUS; and histopathological verification. All patients underwent MP [11C]Acetate PET-MRI of the prostate performed on separate scanners with PET/CT using [11C]Acetate and 3T MP MR imaging. Appropriate statistical tests were used to determine diagnostic accuracy, local and distant staging. RESULTS: MP imaging with two MRI parameters (T2w and DWI) achieved the highest sensitivity, specificity, and diagnostic accuracy of 95%, 68.8%, and 88%, with an AUC of 0.82 for primary PCa detection. Neither assessments with a single parameter (AUC, 0.54-0.79), nor different combinations with up to five parameters (AUC, 0.67-0.79) achieved equally good results. MP [11C]Acetate PET-MRI improved local staging with a sensitivity, specificity, and diagnostic accuracy of 100%, 96%, and 97% compared to MRI alone with 72.2%, 100%, and 95.5%. MP [11C]Acetate PET-MRI correctly detected osseous and liver metastases in five patients. CONCLUSIONS: MP [11C]Acetate PET-MRI merges morphologic with functional information, and allows insights into tumor biology. MP [11C]Acetate PET-MRI with two MRI-derived parameters (T2 and DWI) yields the highest diagnostic accuracy. The addition of more parameters does not improve diagnostic accuracy of primary PCa detection. MP [11C]Acetate PET-MRI facilitates improved local and distant staging, providing "one-stop" staging in patients with primary PCa, and therefore has the potential to improve therapy. PATIENT SUMMARY: In this report we investigated MP [11C]Acetate PET-MRI for detection, local and distant staging of prostate cancer. We demonstrate that MP [11C]Acetate PET-MRI with two MRI-derived parameters (T2 and DWI) achieves the best diagnostic accuracy for primary prostate cancer detection and that MP [11C]Acetate PET-MRI enables an improved local and distant staging.


Subject(s)
Acetates , Carbon Radioisotopes , Magnetic Resonance Imaging , Multimodal Imaging , Positron Emission Tomography Computed Tomography , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Aged, 80 and over , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Neoplasm Staging
12.
NMR Biomed ; 30(6)2017 Jun.
Article in English | MEDLINE | ID: mdl-28295818

ABSTRACT

To demonstrate the accuracy of fully automated, quantitative, volumetric measurement of the amount of fibroglandular breast tissue (FGT), using MRI, and to investigate the impact of different MRI sequences using anthropomorphic breast phantoms as the ground truth. In this study, 10 anthropomorphic breast phantoms that consisted of different known fractions of adipose and protein tissue, which closely resembled normal breast parenchyma, were developed. Anthropomorphic breast phantoms were imaged with a 1.5 T unit (Siemens, Avantofit) using an 18-channel breast coil. The sequence protocol consisted of an isotropic Dixon sequence (Di), an anisotropic Dixon sequence (Da), and T1 3D FLASH sequences with and without fat saturation (T1). Fully automated, quantitative, volumetric measurement of FGT for all anthropomorphic phantoms and sequences was performed and correlated with the amounts of fatty and protein components in the phantoms as the ground truth. Fully automated, quantitative, volumetric measurements of FGT with MRI for all sequences ranged from 5.86 to 61.05% (mean 33.36%). The isotropic Dixon sequence yielded the highest accuracy (median 0.51%-0.78%) and precision (median range 0.19%) compared with anisotropic Dixon (median 1.92%-2.09%; median range 0.55%) and T1 -weighted sequences (median 2.54%-2.46%; median range 0.82%). All sequences yielded good correlation with the FGT content of the anthropomorphic phantoms. The best correlation of FGT measurements was identified for Dixon sequences (Di, R2  = 0.999; Da, R2  = 0.998) compared with conventional T1 -weighted sequences (R2  = 0.971). MRI yields accurate, fully automated, quantitative, volumetric measurements of FGT, an increasingly important and sensitive imaging biomarker for breast cancer risk. Compared with conventional T1 sequences, Dixon-type sequences show the highest correlation and reproducibility for automated, quantitative, volumetric FGT measurements using anthropomorphic breast phantoms as the ground truth.


Subject(s)
Breast/anatomy & histology , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Automation , Female , Humans
13.
J Magn Reson Imaging ; 46(4): 1107-1114, 2017 10.
Article in English | MEDLINE | ID: mdl-28181333

ABSTRACT

PURPOSE: To determine which of three gadoxetic acid injection techniques best reduced the contrast-related arterial-phase motion artifacts. MATERIALS AND METHODS: This Institutional Review Board (IRB)-approved, retrospective study included a cohort of 78 consecutive patients who each had serial gadoxetic acid-enhanced 3.0T magnetic resonance imaging (MRI) of the liver (0.025 mmol/kg body weight) performed with at least two of three injection techniques: M1 test bolus, undiluted, power-injected 1 mL/s; M2 test bolus, diluted 50% with saline, power-injected 1 mL/s; M3 fixed delay, undiluted, manually injected. Blinded to the injection method, three readers independently rated the randomized images for arterial-phase motion artifacts, arterial-phase timing, and arterial-phase lesion visibility using a four-point Likert scale. RESULTS: Regarding respiratory artifacts, gadoxetic acid arterial-phase images were judged better with M3 (2.7 ± 0.7) and were significantly less than those with M1 (2.1 ± 1.1) (P = 0.0001). Arterial-phase M2 (2.50 ± 0.89) images were rated significantly better than arterial-phase M1 images (P = 0.012), but the difference between arterial-phase images with M3 and M2 scores was not statistically significant (P = 0.49). Arterial-phase timing was significantly better for M1 compared to M3, and for M2 compared to M3 (P < 0.0001 for both). The area under the curve was 0.59-0.68. However, there was no significant difference between M1 and M2 (P = 0.35). With regard to arterial-phase lesion visibility, there was no significant difference in the ratings between any of the three injection techniques (P = 0.29-0.72). Interreader agreement was moderate to substantial (κ = 0.41-0.62). CONCLUSION: A diluted, power-injected protocol (M2) seems to provide good timing and minimize artifacts compared with two other injection methods. No significant difference was found in lesion visibility between these three methods. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1107-1114.


Subject(s)
Artifacts , Contrast Media/administration & dosage , Digestive System/diagnostic imaging , Gadolinium DTPA/administration & dosage , Magnetic Resonance Imaging/methods , Respiration , Female , Humans , Male , Middle Aged , Motion , Retrospective Studies
14.
NMR Biomed ; 29(10): 1445-53, 2016 10.
Article in English | MEDLINE | ID: mdl-27553252

ABSTRACT

Diffusion-weighted MRI (DWI) provides insights into tissue microstructure by visualization and quantification of water diffusivity. Quantitative evaluation of the apparent diffusion coefficient (ADC) obtained from DWI has been proven helpful for differentiating between malignant and benign breast lesions, for cancer subtyping in breast cancer patients, and for prediction of response to neoadjuvant chemotherapy. However, to further establish DWI of breast lesions it is important to evaluate the quantitative imaging biomarker (QIB) characteristics of reproducibility, repeatability, and diagnostic accuracy. In this intra-individual prospective clinical study 40 consecutive patients with suspicious findings, scheduled for biopsy, underwent an identical 3T breast MRI protocol of the breast on two consecutive days (>24 h). Mean ADC of target lesions was assessed (two independent readers) in four separate sessions. Reproducibility, repeatability, and diagnostic accuracy between examinations (E1, E2), readers (R1, R2), and measurements (M1, M2) were assessed with intraclass correlation coefficients (ICCs), coefficients of variation (CVs), Bland-Altman plots, and receiver operating characteristic (ROC) analysis with calculation of the area under the ROC curve (AUC). The standard of reference was either histopathology (n = 38) or imaging follow-up of up to 24 months (n = 2). Eighty breast MRI examinations (median E1-E2, 2 ± 1.7 days, 95% confidence interval (CI) 1-2 days, range 1-11 days) in 40 patients (mean age 56, standard deviation (SD) ±14) were evaluated. In 55 target lesions (mean size 25.2 ± 20.8 (SD) mm, range 6-106 mm), mean ADC values were significantly (P < 0.0001) higher in benign (1.38, 95% CI 1.27-1.49 × 10(-3)  mm(2) /s) compared with malignant (0.86, 95% CI 0.81-0.91 × 10(-) (3)  mm(2) /s) lesions. Reproducibility and repeatability showed high agreement for repeated examinations, readers, and measurements (all ICCs >0.9, CVs 3.2-8%), indicating little variation. Bland-Altman plots demonstrated no systematic differences, and diagnostic accuracy was not significantly different in the two repeated examinations (all ROC curves >0.91, P > 0.05). High reproducibility, repeatability, and diagnostic accuracy of DWI provide reliable characteristics for its use as a potential QIB, to further improve breast lesion detection, characterization, and treatment monitoring of breast lesions.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Adolescent , Adult , Aged , Aged, 80 and over , Biomarkers , Female , Humans , Image Enhancement/methods , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Young Adult
15.
PLoS One ; 11(5): e0155333, 2016.
Article in English | MEDLINE | ID: mdl-27167829

ABSTRACT

OBJECTIVES: To investigate fused multiparametric positron emission tomography/magnetic resonance imaging (MP PET/MRI) at 3T in patients with locally advanced cervical cancer, using high-resolution T2-weighted, contrast-enhanced MRI (CE-MRI), diffusion-weighted imaging (DWI), and the radiotracers [18F]fluorodeoxyglucose ([18F]FDG) and [18F]fluoromisonidazol ([18F]FMISO) for the non-invasive detection of tumor heterogeneity for an improved planning of chemo-radiation therapy (CRT). MATERIALS AND METHODS: Sixteen patients with locally advanced cervix were enrolled in this IRB approved and were examined with fused MP [18F]FDG/ [18F]FMISO PET/MRI and in eleven patients complete data sets were acquired. MP PET/MRI was assessed for tumor volume, enhancement (EH)-kinetics, diffusivity, and [18F]FDG/ [18F]FMISO-avidity. Descriptive statistics and voxel-by-voxel analysis of MRI and PET parameters were performed. Correlations were assessed using multiple correlation analysis. RESULTS: All tumors displayed imaging parameters concordant with cervix cancer, i.e. type II/III EH-kinetics, restricted diffusivity (median ADC 0.80x10-3mm2/sec), [18F]FDG- (median SUVmax16.2) and [18F]FMISO-avidity (median SUVmax3.1). In all patients, [18F]FMISO PET identified the hypoxic tumor subvolume, which was independent of tumor volume. A voxel-by-voxel analysis revealed only weak correlations between the MRI and PET parameters (0.05-0.22), indicating that each individual parameter yields independent information and the presence of tumor heterogeneity. CONCLUSION: MP [18F]FDG/ [18F]FMISO PET/MRI in patients with cervical cancer facilitates the acquisition of independent predictive and prognostic imaging parameters. MP [18F]FDG/ [18F]FMISO PET/MRI enables insights into tumor biology on multiple levels and provides information on tumor heterogeneity, which has the potential to improve the planning of CRT.


Subject(s)
Carcinoma, Squamous Cell/diagnostic imaging , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Positron-Emission Tomography/methods , Uterine Cervical Neoplasms/diagnostic imaging , Adult , Aged , Carcinoma, Squamous Cell/pathology , Disease Progression , Female , Fluorodeoxyglucose F18/pharmacokinetics , Humans , Image Interpretation, Computer-Assisted , Middle Aged , Misonidazole/analogs & derivatives , Misonidazole/pharmacokinetics , Neoplasm Staging , Retrospective Studies , Tumor Burden , Uterine Cervical Neoplasms/pathology
16.
Eur Radiol ; 26(11): 3908-3916, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26984430

ABSTRACT

PURPOSE: The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. METHODS: This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients underwent 487 MR-guided VABB using three different 8-10-gauge-VABB devices (Atec-9-gauge,A; Mammotome-8-gauge,M; Vacora-10-gauge,V). VABB data (lesion-type, size, biopsy device, histopathology) were compared to final diagnosis (surgery, n = 210 and follow-up, n = 277). Chi-square, and Kruskal-Wallis tests were applied. P values < 0.05 were considered significant. RESULTS: Final diagnosis was malignant in 104 (21.4 %), high risk in 64 (13.1 %) and benign in 319 (65.5 %) cases. Eleven of 328 (3.4 %) benign-rated lesions were false-negative (1/95, 1.1 %, A; 2/73, 2.7 %, M; 8/160 5.0 % V; P = 0.095). Eleven high-risk (11/77, 14.3 %) lesions proved to be malignant (3/26, 11.5 % A; 4/12, 33.3 % M; 4/39, 10.3 % V; P = 0.228). Five of 34 (14.7 %) DCIS were upgraded to invasive cancer (2/15, 13.3 %, A; 1/6, 16.6 % M; 2/13, 15.3 %, V; P = 0.977). Lesion size (P = 0.05) and type (mass vs. non-mass, P = 0.107) did not differ significantly. CONCLUSION: MR-guided VABB is an accurate method for diagnosis of MRI-only lesions. No significant differences on false-negative and underestimation rates were observed between three different biopsy devices. KEY POINTS: • MR-guided VABB is an accurate procedure for the diagnosis of MRI-only lesions. • Similar false-negative and underestimation rates allow all three different MR-guided VABB devices for clinical application. • High-risk lesions should undergo surgery due to a substantial underestimation rate. • Agreement between MR-guided VABB and final diagnosis (benign/malignant) was 95.5% (465/487).


Subject(s)
Breast Neoplasms/pathology , Breast/pathology , Carcinoma, Ductal, Breast/pathology , Adult , Aged , Biopsy, Needle/methods , Female , Humans , Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Middle Aged , Retrospective Studies , Vacuum
17.
World J Urol ; 34(5): 649-56, 2016 May.
Article in English | MEDLINE | ID: mdl-26407583

ABSTRACT

PURPOSE: The aim of our study was to assess whether multiparametric magnetic resonance imaging (MP-MRI) of the prostate with three parameters (PS3: T2-weighted, DWI, and DCE) benefits from an additional fourth parameter (PS4: including (1)H-MRSI) in the detection and grading of prostate cancer (PCa) at 3 T. METHODS: MP-MRI was performed in 64 patients (mean 66.7 years, mean PSA 13 ng/ml). Reference standard was obtained by histopathology. Two readers independently evaluated the images. A summation score of each individual parameter for three parameters (PS3) and for four parameters (PS4) was calculated. RESULTS: In 52 (81.3 %) of 64 patients, histopathology confirmed a PCa. The diagnostic performance for PCa detection of PS4 (O1: 91.7 %, O2: 91.3 %) equaled that of PS3 (O1: 92.8 %, O2: 92.2 %, P > 0.05). Prediction of high-grade PCa by PS4 (O1: 75.1 %, O2: 74.7 %) was as good as with PS3 (O1: 75.1 %, O2: 72.8 %, P > 0.05). Kappa agreement between the two readers was substantial (0.734 PS4) to moderate (0.558 PS3). CONCLUSIONS: MP-MRI with four parameters including (1)H-MRSI does not increase the detection and grading of prostate cancer at 3 T compared to MP-MRI with three parameters. A sum score accurately detects PCa at 3 T without an endorectal coil and shows potential for the prediction of tumor grade.


Subject(s)
Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Prostatic Neoplasms/diagnostic imaging , Adult , Aged , Aged, 80 and over , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Male , Middle Aged , Prospective Studies
18.
Anticancer Res ; 35(12): 6787-91, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26637897

ABSTRACT

AIM: To evaluate the diagnostic accuracy of (11)C-acetate positron-emission tomography (PET) in the detection of bone metastasis in patients with prostate cancer with biochemical recurrence. PATIENTS AND METHODS: Ninety patients (100%) with rising prostate-specific antigen (PSA) levels (>0.2 ng/ml) after radical prostatectomy, who had both (11)C-acetate PET and bone scan performed and who had clinical follow-up/imaging follow-up for bone metastasis, considered a gold standard, were included. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for (11)C-acetate PET were calculated on a per-patient basis. RESULTS: (11)C-Acetate PET and (99m)Tc-dicarboxypropane-diphosphonate findings were concordant in 84 (93.3%) patients [35 (38.9%) true-positive, 49 (54.4%) true-negative]. Discordant findings were observed in six patients (6.7%). (11)C-Acetate PET presented two (2.2%) false-positive and four (4.4%) false-negative findings. The sensitivity, specificity, PPV, and NPV for (11)C-acetate PET were 89.7%, 96.1%, 94.6%, and 92.2%, respectively. The median PSA of patients with multiple skeletal metastases (median=23.64 ng/ml, range=3.16-551.1 ng/ml) differed significantly (p=0.018) from that of patients with focal metastases (median=6.7 ng/ml, range=0.31-12.8 ng/ml). CONCLUSION: (11)C-Acetate PET is a useful tool for patients with prostate cancer with biochemical recurrence, as it can depict multiple sites of recurrence and in particularly shows a high diagnostic value equivalent to that of bone scan for the detection of bone metastases.


Subject(s)
Acetates/chemistry , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/secondary , Carbon/chemistry , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiopharmaceuticals/chemistry , Female , Humans , Male , Middle Aged , Neoplasm Metastasis , Neoplasm Recurrence, Local/diagnostic imaging , Positron-Emission Tomography/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...