Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Am J Obstet Gynecol ; 2023 Nov 25.
Article in English | MEDLINE | ID: mdl-38008149

ABSTRACT

OBJECTIVE: This study aimed to analyze and summarize the evidence on the accuracy of different ultrasound methods in the diagnosis of retained products of conception. DATA SOURCES: We searched Ovid SP, the Cumulative Register to Nursing & Allied Health Literature, EBSCO, and grey literature including Core, Trip, Networked Digital Library of Theses and Dissertations Global ETD search, BMJ Best Practice, PubMed, GreyLit report website (http://www.greylit.org/), Cochrane Central Register of Controlled Trials, and Google scholar (https://scholar.google.com/). STUDY ELIGIBILITY CRITERIA: We included prospective and retrospective cross-sectional or Cohort studies that evaluated both ultrasound findings (before management of retained products of conception) and histopathologic results of retained products of conception at all gestational ages. METHODS: We used Covidence for data extraction from the studies and quality assessment. The meta-analysis was performed using RevMan 5.4 (forest plot), MetaDTA version 2.01, and Meta-DiSc 2.0 online software. RESULTS: In total, 11 studies were eligible for data extraction and meta-analysis. The total number of study participants from these 11 studies were 1567. Of these, 9 studies were included to test the accuracy of an echogenic mass, 4 studies analyzed the accuracy of endometrial thickness, and 5 studies analyzed the accuracy of color Doppler flow to predict retained products of conception. We found that echogenic mass had the highest sensitivity, specificity, and diagnostic odds ratio for predicting retained products of conception. The sensitivity, specificity, and diagnostic odds ratio were 0.915 (95% confidence interval, 0.844-0.955), 0.843 (95% confidence interval, 0.615-0.947), and 57.787 (95% confidence interval, 15.171-220.112), respectively. The diagnostic threshold for endometrial thickness was set at 10 mm with a sensitivity, specificity, and diagnostic odds ratio of 0.667 (95% confidence interval, 0.072-0.981), 0.866 (95% confidence interval, 0.375-0.986), and 12.927 (95% confidence interval, 0.23-726.582). The sensitivity, specificity, and diagnostic odds ratio of color Doppler flow were 0.850 (95% confidence interval, 0.756-0.913), 0.406 (95% confidence interval, 0.198-0.655), and 3.893 (95% confidence interval, 1.005-15.081). CONCLUSION: Our review concluded that an echogenic mass is the most sensitive and specific predictor of retained products of conception after any pregnancy event. The most important limitation of our review is that the design of the studies included led to significant statistical heterogeneity.

2.
Eur J Obstet Gynecol Reprod Biol ; 203: 320-5, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27423530

ABSTRACT

OBJECTIVE: The aim of this study was to correlate manual and spherical endometrial spatio-temporal image correlation (STIC) vascularity indices with assisted reproductive treatment (ART) outcomes. STUDY DESIGN: STIC ultrasound assessments of the endometrium were carried out at three time-points in 127 women in a prospective observational study. RESULTS: Biochemical pregnancy rate was 69% (88/127), with a biochemical and clinical pregnancy loss of 17%. Endometrial STIC vascularity indices in the assessed time-points did not differ between subjects who achieved a clinical pregnancy and those who did not (P>0.05). For first trimester miscarriage, minimal manual vascularization index (VI) at oocyte collection (cut-off value ≥0.7; sensitivity 80.0% and specificity 68.1%) demonstrated the highest area under the curve (AUC) of 0.8. CONCLUSION: In summary, STIC modality is not a useful tool to predict ART outcome, however manual STIC analysis of endometrial vascularity seems to be more accurate in predicting first trimester pregnancy loss.


Subject(s)
Endometrium/diagnostic imaging , Reproductive Techniques, Assisted , Ultrasonography/methods , Female , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Pregnancy , Pregnancy Rate , Prospective Studies , Sensitivity and Specificity
3.
Ultrasound Med Biol ; 41(11): 2798-805, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26278634

ABSTRACT

Our aim in the study described here was to assess the feasibility of spatiotemporal image correlation power Doppler quantification of the endometrium with two techniques: spherical samples and whole tissue. We scanned 51 women in the midluteal phase of the menstrual cycle: STIC assessment of the whole endometrium was not possible in 10% of cases, whereas spherical analysis was possible in all. The time taken for data set analysis was much longer for the whole endometrium compared with spherical analysis (1478.9 ± 291 s vs. 266.8 ± 39.3 s, p < 0.05). Intra-class correlation coefficients for the vascularization flow index (VFI) were similar for both methods. Volumetric vascularity indices were higher when spherical sampling was conducted. Significant cycle-to-cycle variability in the vascularity indices was present, with coefficients of variation exceeding 20% for both techniques. We found that STIC power Doppler quantification of the whole endometrium is possible in the majority of cases, however, it is time consuming and limited by significant cycle-to-cycle variability.


Subject(s)
Endometrium/blood supply , Endometrium/diagnostic imaging , Imaging, Three-Dimensional/methods , Ultrasonography, Doppler/methods , Adult , Cohort Studies , Feasibility Studies , Female , Humans , Prospective Studies , Reproducibility of Results , Young Adult
5.
Reprod Biomed Online ; 28(4): 409-23, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24581986

ABSTRACT

Recurrent implantation failure (RIF) is an iatrogenic condition, being the result of repetitive unsuccessful cycles of IVF or intracytoplasmic sperm injection (ICSI) treatment. The aim of this review was to assess the definitions of RIF used in literature as well as suggest a uniform definition of this condition. A systematic search of MEDLINE, Embase and Cochrane Library was conducted. The most commonly stated definitions described RIF as 'three or more failed treatment cycles' or 'two or more failed cycles'. Other identified definitions were based solely on the number of embryos transferred in previous cycles or combined the number of previously failed cycles with the number of transferred embryos. Several other definitions were also identified. This review highlights the lack of uniformity of the definition of RIF. Based on the available literature and the expert opinion of the authors, RIF should be defined as the absence of implantation after two consecutive cycles of IVF, ICSI or frozen embryo replacement cycles where the cumulative number of transferred embryos was no less than four for cleavage-stage embryos and no less than two for blastocysts, with all embryos being of good quality and of appropriate developmental stage.


Subject(s)
Embryo Implantation , Embryo Transfer/adverse effects , Female , Fertilization in Vitro/adverse effects , Humans , Pregnancy , Pregnancy Rate , Sperm Injections, Intracytoplasmic/adverse effects , Terminology as Topic
6.
J Ultrasound Med ; 32(10): 1831-6, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24065264

ABSTRACT

Spatiotemporal image correlation can be used to acquire 3-dimensional power Doppler information across a single cardiac cycle. Assessment and comparison of the systolic and diastolic components of the data sets allow measurement of the recently introduced "volumetric pulsatility index" (vPI) through algorithms comparable with those used in 2-dimensional Doppler waveform analysis. The vPI could potentially overcome the dependency on certain machine settings, such as power, color gain, pulse repetition frequency, and attenuation, since these factors would affect the power Doppler signal equally throughout the cardiac cycle. The objective of this study was to compare the effect of color gain on the vascularization index (VI), vascularization-flow index (VFI), and vPI using an in vitro flow phantom model. We separated gains into 3 bands: -8 to -1 (no noise), -1 to +5 (low noise), and +5 to +8 (obvious noise). The vPI was determined from the 3-dimensional VI or VFI using the formula vPI = (maximum - minimum)/mean. Using no-noise gains, we observed that although the VI and VFI increased linearly with gain, the vPI was substantially less dependent on this adjustment. The VI and VFI continued to increase linearly with gain, whereas the vPI decreased slightly using low-noise gains. When gain was increased above the lower limit of obvious noise (+5), the VI and VFI increased noticeably, and there were marked reductions in both vPI values. We conclude that the vPI is less affected by changes in color gain than the VI and VFI at no-noise gains.


Subject(s)
Algorithms , Blood Vessels/diagnostic imaging , Blood Vessels/physiology , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Pulsatile Flow/physiology , Ultrasonography, Doppler/methods , Blood Flow Velocity/physiology , Computer Simulation , Humans , Image Enhancement/methods , Models, Cardiovascular , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Spatio-Temporal Analysis , Ultrasonography, Doppler/instrumentation
7.
BMJ Case Rep ; 20102010 May 19.
Article in English | MEDLINE | ID: mdl-22750921

ABSTRACT

This case report describes a rare but fatal presentation of amyloidosis. Multiple organs and systems can be affected by the condition. Cholestatic jaundice is a infrequent manifestation of amyloidosis. An 80-year-old patient died within a month after onset of jaundice as a result of irreversible damage caused by deposition of amyloid. The relatively short period of time did not allow a tissue sample to be obtained from the patient and the final diagnosis was made postmortem.


Subject(s)
Amyloidosis/complications , Jaundice, Obstructive/etiology , Aged, 80 and over , Amyloidosis/diagnosis , Contrast Media , Diagnosis, Differential , Fatal Outcome , Female , Hemorrhage/diagnosis , Hemorrhage/etiology , Humans , Immunoglobulin Light-chain Amyloidosis , Jaundice, Obstructive/diagnosis , Liver Failure/diagnosis , Liver Failure/etiology , Pancreatitis/diagnosis , Pancreatitis/etiology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...