Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cell Mol Biol (Noisy-le-grand) ; 46(2): 221-35, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10774916

ABSTRACT

Four different hyphenated techniques: microbore reversed phase (RP) HPLC-ICP MS, CZE-ICP MS, RP HPLC-ES MS and CZE-ES MS were investigated for the characterization of metallothionein-metal complexes under neutral pH conditions. Particular attention was given to the differentiation between metallothionein and artifact signals, identification of mixed-metal complexes, and the validity of the molecular mass as the identification parameter of the different MT iso- and sub-isoforms. Despite the similar morphology of chromatograms and electrophoregrams mass spectrometry revealed different origin of the apparently corresponding peaks. The performance of the four above mentioned techniques was characterized using the example of rabbit liver MT-1 preparation. Reversed-phase HPLC with post-column acidification prior to ES MS was judged to be the most versatile technique for the characterization of metal complexes with metallothioneins but other techniques offer valuable auxiliary information.


Subject(s)
Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary/methods , Mass Spectrometry/methods , Metallothionein/chemistry , Metals/chemistry , Animals , Cadmium/chemistry , Copper/chemistry , Hydrogen-Ion Concentration , Liver/chemistry , Protein Isoforms , Rabbits , Time Factors , Zinc/chemistry
2.
Talanta ; 51(4): 817-24, 2000 Apr 03.
Article in English | MEDLINE | ID: mdl-18967914

ABSTRACT

Optimum conditions for the reversed-phase liquid chromatographic separation of uranium as U(VI)-F(-)-(5-Br-PADAP) [5-Br-PADAP is 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol] ternary complex on the end-capped C18 column were evaluated. The developed sensitive, selective and versatile method allows to determine uranium in the wide concentration range 0.2-120.0 mug ml(-1) (detection limit, DL, is 0.15 mug ml(-1) for 20 mul loop). Solvent mixture, acetonitrile+water (65+35, v/v) containing fluoride in concentration 3x10(-3) mol l(-1) (pH 5.5) was used as eluent. Double action of fluoride present in eluent - as stabilising agent of the ternary system and modifier of the stationary phase was evaluated. In order to prove appearance of the modifying effect of fluoride on the stationary phase the new chromatographic probe - system Zr(IV)-(5-Br-PADAP)/Zr(IV)-F(-)-(5-Br-PADAP) was introduced as a tool for the detection of F(-) presence on the surface.

SELECTION OF CITATIONS
SEARCH DETAIL
...