Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Electrophoresis ; 29(5): 1180-8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18275036

ABSTRACT

The effect of the phase ratio on the electrophoretic and chromatographic properties of unilamellar vesicles comprised of cetyltrimethylammonium bromide (CTAB) and sodium octyl sulfate (SOS) was investigated in EKC. The surfactant concentration of the vesicles was 0.9, 1.2, 1.5, and 1.8% w/v, with a mole ratio of 1:3.66 (CTAB/SOS). Results were compared to those obtained using SDS micelles at concentrations of 1.0% (w/v, 35 mM) and 1.5% (52 mM). The CTAB/SOS vesicles (0.9-1.8% w/v) provided a significantly larger elution range (5.7 < or = t(ves)/t(0) < or = 8.7) and greater hydrophobic (methylene) selectivity (2.8 < or = alpha(CH2) < or = 3.1) than SDS micelles (3.1 < or = t(mc)/t(0) < or = 3.3; alpha(CH2) = 2.2). Whereas the larger elution range can be attributed to the 25% reduction in EOF due to the interaction of unaggregated CTAB cations and the negatively charged capillary wall, the higher methylene selectivity is likely due to the lower concentration of water expected in the CTAB/SOS vesicle bilayer compared to the Palisades layer of SDS micelles. For a given phase ratio, CTAB/SOS vesicles are somewhat less retentive than SDS micelles, although retention factors comparable to those observed in 1.0-1.5% SDS can be obtained with 1.5-1.8% CTAB/SOS. A linear relationship was observed between phase ratio and retention factor, confirming the validity of the phase ratio model for these vesicles. Unique polar group selectivities and positional isomer shape selectivities were obtained with CTAB/SOS vesicles, with both types of selectivities being nearly independent of the phase ratio. For four sets of positional isomers, the elution order was always para < ortho < meta. Finally, the thermodynamics of solute retention was qualitatively similar to that reported for other surfactant aggregates (micelles and microemulsions); the enthalpic contribution to retention was consistently favorable for all compounds, whereas the entropic contribution was favorable only to hydrophobic solutes.


Subject(s)
Alkanesulfonic Acids/chemistry , Cetrimonium Compounds/chemistry , Chromatography, Micellar Electrokinetic Capillary/methods , Electrophoresis, Capillary/methods , Surface-Active Agents/chemistry , Unilamellar Liposomes/chemistry , Benzene Derivatives/isolation & purification , Cetrimonium , Hydrophobic and Hydrophilic Interactions , Thermodynamics , Viscosity
2.
J Pharm Biomed Anal ; 35(3): 523-34, 2004 May 28.
Article in English | MEDLINE | ID: mdl-15137977

ABSTRACT

I, 5-[3-[3-(4-phenoxy-2-propylphenoxy)-propoxy]-phenyl]-2,4-thiazolidinedione sodium salt, is a dual alpha/gamma peroxisome proliferator-activated receptor (PPAR) agonist for potential use in diabetic patients. The compound has a para-hydroxylated metabolite, II, which has also been shown to exhibit PPAR activity. An LC-MS/MS method for the simultaneous determination of I and its active metabolite (II) in human plasma has been successfully developed. The method consists of treating 0.5 ml plasma with ammonium acetate (pH 9.6; 50mM) and extracting I, II and internal standard (III, Fig. 2) with 5 ml ethyl acetate. The ethyl acetate is evaporated and the samples are reconstituted in 0.1 ml acetonitrile:0.1% formic acid (65:35, v/v). The entire extraction procedure, as well as sample collection, was performed in glass tubes and vials to overcome the analytes adherence to polypropylene. A linear HPLC gradient was used to separate the analyte, metabolite, internal standard, and other interfering, non-quantitated metabolites. Detection was by negative ionization MS/MS on a turbo ionspray probe. Precursor-->product ion combinations were monitored in multiple reaction monitoring (MRM) mode. The linear range is 0.05-20 ng/ml for I and 0.1-20 ng/ml for II. Recoveries were 59.4, 90.1 and 56.8% for I, II and III, respectively. Intraday variation using this method was <==7.0% for I and <==9.2% for II. The method exhibits good linearity and reproducibility for each analyte and good sensitivity, selectivity and robustness when used for the analysis of clinical samples.


Subject(s)
Insulin , Technology, Pharmaceutical/methods , Thiazolidinediones/blood , Gas Chromatography-Mass Spectrometry/methods , Humans , Hydroxylation , Insulin/metabolism , Thiazolidinediones/metabolism
3.
J Pharm Biomed Anal ; 33(1): 73-84, 2003 Sep 15.
Article in English | MEDLINE | ID: mdl-12946533

ABSTRACT

Losartan is an orally active angiotensin II receptor antagonist indicated for the treatment of hypertension. EXP3174 is an active metabolite, which contributes to the overall activity of losartan. Analytical methods for the simultaneous determination of losartan and its active metabolite EXP3174 in human plasma and urine with limited plasma sample size have been developed and validated to support a pediatric clinical program. In both methods, analytes are extracted from the matrixes by liquid-liquid extraction and separated using reverse phase high-performance liquid chromatography (HPLC). A tandem mass spectrometer (MS/MS) with a Turbo ionspray (TIS) interface in multiple-reaction-monitoring (MRM) mode is used for detection of the analytes in both methods. The plasma method has a lower limit of quantitation (LOQ) of 1 ng/ml with a linearity range of 1-500 ng/ml for losartan and EXP3174 using 100 microl of plasma. For the urine method, the LOQ for both losartan and EXP3174 is 2 ng/ml using 0.5 ml of urine, and the linearity range for both analytes is 2-1000 ng/ml. Validation procedures have proven that both methods are robust, accurate, and reproducible. Both methods have been used to assay clinical samples and provided satisfactory results.


Subject(s)
Antihypertensive Agents/analysis , Imidazoles/analysis , Losartan/analysis , Tetrazoles/analysis , Antihypertensive Agents/blood , Antihypertensive Agents/urine , Child, Preschool , Chromatography, High Pressure Liquid , Humans , Imidazoles/blood , Imidazoles/urine , Indicators and Reagents , Losartan/blood , Losartan/urine , Mass Spectrometry , Quality Control , Reference Standards , Reproducibility of Results , Tetrazoles/blood , Tetrazoles/urine