Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Chem Res Toxicol ; 23(3): 578-90, 2010 Mar 15.
Article in English | MEDLINE | ID: mdl-20143881

ABSTRACT

Exposure to environmental chemicals adds to the burden of disease in humans and wildlife to a degree that is difficult to estimate and, thus, mitigate. The ability to assess the impact of existing chemicals for which little to no toxicity data are available or to foresee such effects during early stages of chemical development and use, and before potential exposure occurs, is a pressing need. However, the capacity of the current toxicity evaluation approaches to meet this demand is limited by low throughput and high costs. In the context of EPA's ToxCast project, we have evaluated a novel cellular biosensor system (Factorial (1) ) that enables rapid, high-content assessment of a compound's impact on gene regulatory networks. The Factorial biosensors combined libraries of cis- and trans-regulated transcription factor reporter constructs with a highly homogeneous method of detection enabling simultaneous evaluation of multiplexed transcription factor activities. Here, we demonstrate the application of the technology toward determining bioactivity profiles by quantitatively evaluating the effects of 309 environmental chemicals on 25 nuclear receptors and 48 transcription factor response elements. We demonstrate coherent transcription factor activity across nuclear receptors and their response elements and that Nrf2 activity, a marker of oxidative stress, is highly correlated to the overall promiscuity of a chemical. Additionally, as part of the ToxCast program, we identify molecular targets that associate with in vivo end points and represent modes of action that can serve as potential toxicity pathway biomarkers and inputs for predictive modeling of in vivo toxicity.


Subject(s)
Biosensing Techniques/methods , Environmental Pollutants/adverse effects , Receptors, Cytoplasmic and Nuclear/genetics , Transcription Factors/genetics , Transcription, Genetic/drug effects , Animals , Biosensing Techniques/economics , Biosensing Techniques/instrumentation , Hep G2 Cells , Rabbits , Rats , Response Elements/drug effects
2.
Nat Methods ; 5(3): 253-60, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18297081

ABSTRACT

We developed a high-content reporter system that allows quantitative assessment of activities of multiple transcription factors (TFs) in a eukaryotic cell. The system comprises a library of reporter constructs that are evaluated according to their transcription rates. All reporters produce essentially identical messages that are subjected to 'processing', which generates a spectrum of distinguishable fragments that are analyzed quantitatively. The homogeneity of the reporter library afforded inherently uniform detection conditions for all reporters and provided repeatability, accuracy and robustness of assessment. We showed that this technology can be used to identify pathways transmitting cell responses to inducers, and that the profile of TF activities generated using this system represents a stable and sustained cell signature that clearly distinguishes different cell types and pathological conditions. This technology provides a framework for functional characterization of signal transduction networks through profiling activities of multiple TFs.


Subject(s)
Gene Expression Profiling/methods , Gene Library , Genes, Reporter/physiology , Transcription Factors/genetics , Animals , Carbazoles/pharmacology , Cell Line, Tumor , Colforsin/pharmacology , Humans , Indoles/pharmacology , Oligonucleotide Array Sequence Analysis/methods , Polymerase Chain Reaction , Rats , Receptors, Aryl Hydrocarbon/drug effects , Reproducibility of Results , Transfection/methods , Transforming Growth Factor beta/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...