Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ann Pharm Fr ; 82(1): 96-109, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37625529

ABSTRACT

OBJECTIVE: A simple, highly specific, accurate and fast method by smartphone-based digital imaging was developed for estimating lidocaine hydrochloride in pharmaceutical formulations. MATERIAL AND METHODS: To obtain the images, a Galaxy A03 Core smartphone and an image acquisition device developed in the laboratory were used to control the incident factors in reproducibility of the measurements. The processing of the images was carried out with the Color Grab application. Finally, the absorbance values were calculated using the RGB intensity values of blank, standard, and sample solutions. The proposed method was compared with spectroscopic and chromatographic methods. RESULTS: The reaction between copper and lidocaine hydrochloride was characterized, showing better results in an equimolar ratio and maintaining the pH of the solution above 11.5. The use of the device for the capture of digital images allowed to control those sensitive parameters for reproducibility so that the analytical measurements showed adequate precision and accuracy. Validation of the main parameters of the method showed compliance with acceptance criteria. The application of the method for the analysis of injectable samples achieved reliable results, which were statistically similar to other reference instrumental methods. CONCLUSION: The proposed method presented figures of merit in relation to linearity, precision, selectivity, accuracy, and robustness; it was carried out by designing and manufacturing a device for capturing digital images on a smartphone, which were analyzed to obtain RGB intensity values. These data are finally used to calculate absorbance values of solutions. All these elements provide this work with innovative characteristics in the field of analysis for control of pharmaceutical formulations.


Subject(s)
Lidocaine , Smartphone , Cost-Benefit Analysis , Drug Compounding , Lidocaine/analysis , Lidocaine/chemistry , Reproducibility of Results
2.
Antioxidants (Basel) ; 11(12)2022 Dec 05.
Article in English | MEDLINE | ID: mdl-36552616

ABSTRACT

With the explosive growth of the dietary supplements industry, new demands have emerged that cannot be faced with the sophisticated instrumentation available in well-equipped laboratories. In particular, there is a demand for simplified and easy-to-use instruments, capable of providing results in short times of analysis. In this study, a hand-portable miniaturized liquid chromatograph (portable LC) has been tested for the determination of chlorogenic acids (CGAs) in products intended to supplement the diet and elaborated with green coffee extracts. CGAs offer several health benefits due to their antioxidant properties, and an increasing number of dietary supplements are marketed with claimed high contents of these compounds. The results obtained with the proposed portable LC approach have been compared with those obtained with two other miniaturized benchtop liquid chromatography instruments, namely, a capillary liquid chromatograph (capLC) and a nano liquid chromatograph (nanoLC). Although compared with the methods that used the benchtop instruments, the sensitivity attainable was lower, the portable LC instrument provided a comparable analytical performance for the quantification of the main GCAs at low mg g-1 levels, and it was clearly superior in terms of speed. The proposed portable LC-based method can be applied to assess the content and distribution profile of the predominant CGAs in this kind of dietary supplement. It can be also used to estimate the antioxidant power due to CGAs, as well as their preservation state.

3.
Eur J Pediatr ; 181(12): 4175-4182, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36169712

ABSTRACT

The purpose of this paper is to verify whether the concentrations of caffeine in saliva are comparable to serum concentrations in preterm infants who are treated with caffeine for apnea of prematurity. This is a prospective observational study. Eligible participants were newborn infants < 37 weeks of gestational age treated with oral or intravenous caffeine for apnea of prematurity. Two paired samples of saliva and blood were collected per patient. Tube solid-phase microextraction coupled online to capillary liquid chromatography with diode array detection was used for analysis. A total of 47 infants with a median gestational age of 28 [26-30] weeks and a mean of 1.11 ± 0.4 kg of birth weight. Median postmenstrual age, when samples were collected, was 31 [29-33] weeks. Serum caffeine median levels of 19.30 µg/mL [1.9-53.90] and salivary caffeine median levels of 16.36 µg/mL [2.20-56.90] were obtained. There was a strong positive Pearson's correlation between the two variables r = 0.83 (p < 0.001). CONCLUSION: The measurement of salivary caffeine concentrations after intravenous or oral administration offers an alternative to serum caffeine monitoring in apnea of prematurity. Measurement of salivary concentration minimizes blood draws, improves blood conservation, and subsequently minimizes painful procedures in premature infants. WHAT IS KNOWN: • Salivary sampling may be useful when is applied to extremely low birth weight infant, in whom blood sampling must be severely restricted. WHAT IS NEW: • The measurement of caffeine salivary concentrations after intravenous or oral administration offers an alternative to serum caffeine monitoring in apnoea of prematurity. • Salivary sampling may be a valid non-invasive alternative that could be used to individualize and optimize caffeine dose.


Subject(s)
Infant, Newborn, Diseases , Infant, Premature, Diseases , Infant , Infant, Newborn , Humans , Apnea/drug therapy , Caffeine/analysis , Caffeine/therapeutic use , Infant, Premature , Infant, Premature, Diseases/diagnosis , Infant, Premature, Diseases/drug therapy
4.
Pharmaceuticals (Basel) ; 14(6)2021 Jun 17.
Article in English | MEDLINE | ID: mdl-34204518

ABSTRACT

Dietary supplements of botanical origin are increasingly consumed due to their content of plant constituents with potential benefits on health and wellness. Among those constituents, terpenes are gaining attention because of their diverse biological activities (anti-inflammatory, antibacterial, geroprotective, and others). While most of the existing analytical methods have focused on establishing the terpenic fingerprint of some plants, typically by gas chromatography, methods capable of quantifying representative terpenes in herbal preparations and dietary supplements with combined high sensitivity and precision, simplicity, and high throughput are still necessary. In this study, we have explored the utility of capillary liquid chromatography (CapLC) with diode array detection (DAD) for the determination of different terpenes, namely limonene, linalool, farnesene, α-pinene, and myrcene. An innovative method is proposed that can be applied to quantify the targets at concentration levels as low as 0.006 mg per gram of sample with satisfactory precision, and a total analysis time <30 min per sample. The reliability of the proposed method has been tested by analyzing different dietary supplements of botanical origin, namely three green coffee extract-based products, two fat burnings containing Citrus aurantium (bitter orange), and an herbal preparation containing lime and leaves of orange trees.

5.
Molecules ; 25(10)2020 May 25.
Article in English | MEDLINE | ID: mdl-32466305

ABSTRACT

Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phases. Capillary GC columns may also be unsuitable when highly selective extractions are needed. In this work, we provide an overview of the extractive capillaries that have been specifically developed for capillary LC (capLC) and nano LC (nanoLC) to enhance the overall performance of the IT-SPME, the chromatographic separation, and the detection. Different monolithic polymers, such as silica C18 and C8 polymers, molecularly imprinted polymers (MIPs), polymers functionalized with antibodies, and polymers reinforced with different types of carbon nanotubes, metal, and metal oxide nanoparticles (including magnetic nanoparticles), and restricted access materials (RAMs) will be presented and critically discussed.


Subject(s)
Chromatography, Liquid/methods , Complex Mixtures/chemistry , Environmental Pollutants/isolation & purification , Organophosphorus Compounds/isolation & purification , Polycyclic Aromatic Hydrocarbons/isolation & purification , Solid Phase Microextraction/methods , Animals , Bacteria/chemistry , Chromatography, Liquid/instrumentation , Fresh Water/chemistry , Humans , Immunosorbents/chemistry , Metal Nanoparticles/chemistry , Molecularly Imprinted Polymers/chemistry , Nanotubes, Carbon/chemistry , Silicon Dioxide/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...