Anaesth Crit Care Pain Med ; 42(6): 101300, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37709201

ABSTRACT

BACKGROUND: Accuracy and timing of antibiotic therapy remain a challenge for lower respiratory tract infections. New molecular techniques using Multiplex Polymerase Chain Reaction, including the FilmArray® Pneumonia Plus Panel [FAPP], have been developed to address this. The aim of this study is to evaluate the FAPP diagnostic performance for the detection of the 15 typical bacteria of the panel from respiratory samples in a meta-analysis from a systematic review. METHODS: We searched PubMed and EMBASE from January 1, 2010, to December 31, 2022, and selected any study on the FAPP diagnostic performance on respiratory samples compared to the reference standard, bacterial culture. The main outcome was the overall diagnostic accuracy with sensitivity and specificity. We calculated the log Diagnostic Odds Ratio and analyzed performance for separate bacteria, antimicrobial resistance genes, and according to the sample type. We also reported the FAPP turnaround time and the out-of-panel bacteria number and species. This study is registered with PROSPERO (CRD42021226280). RESULTS: From 10 317 records, we identified 30 studies including 8 968 samples. Twenty-one were related to intensive care. The overall sensitivity and specificity were 94% [95% Confidence Interval (CI) 91-95] and 98% [95%CI 97-98], respectively. The log Diagnostic Odds Ratio was 6.35 [95%CI 6.05-6.65]. 9.3% [95%CI 9.2-9.5] of bacteria detected in culture were not included in the FAPP panel. CONCLUSION: This systematic review reporting the FAPP evaluation revealed a high accuracy. This test may represent an adjunct tool for pulmonary bacterial infection diagnostic and antimicrobial stewardship. Further evidence is needed to assess the impact on clinical outcome.


Subject(s)
Bacterial Infections , Pneumonia , Respiratory Tract Infections , Humans , Bacteria/genetics , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/microbiology , Multiplex Polymerase Chain Reaction/methods
2.
Microbiol Spectr ; 11(1): e0254722, 2023 02 14.
Article in English | MEDLINE | ID: mdl-36519852

ABSTRACT

The FilmArray Blood Culture Identification 2 panel (BCID2; bioMérieux) is a fully automated PCR-based assay for identifying bacteria, fungi, and bacterial resistance markers in positive blood cultures (BC) in about 1 h. In this multicenter study, we evaluated the performance of the BCID2 panel for pathogen detection in positive BC. Conventional culture and BCID2 were performed in parallel at four tertiary-care hospitals. We included 152 positive BC-130 monomicrobial and 22 polymicrobial cultures-in this analysis. The BCID2 assay correctly identified 90% (88/98) of Gram-negative and 89% (70/79) of Gram-positive bacteria. Five bacterial isolates targeted by the BCID2 panel and recovered from five positive BC, including three polymicrobial cultures, were missed by the BCID2 assay. Fifteen isolates were off-panel organisms, accounting for 8% (15/182) of the isolates obtained from BC. The mean positive percent agreement between the BCID2 assay and standard culture was 97% (95% confidence interval, 95 to 99%), with agreement ranging from 67% for Candida albicans to 100% for 17 targets included in the BCID2 panel. BCID2 also identified the blaCTX-M gene in seven BC, including one for which no extended-spectrum ß-lactamase (ESBL)-producing isolate was obtained in culture. However, it failed to detect ESBL-encoding genes in three BC. Two of the 18 mecA/C genes detected by the BCID2 were not confirmed. No carbapenemase, mecA/C, or MREJ targets were detected. The median turnaround time was significantly shorter for BCID2 than for culture. The BCID2 panel may facilitate faster pathogen identification in bloodstream infections. IMPORTANCE Rapid molecular diagnosis combining the identification of pathogens and the detection of antibiotic resistance genes from positive blood cultures (BC) can improve the outcome for patients with bloodstream infections. The FilmArray BCID2 panel, an updated version of the original BCID, can detect 11 Gram-positive bacteria, 15 Gram-negative bacteria, 7 fungal pathogens, and 10 antimicrobial resistance genes directly from a positive BC. Here, we evaluated the real-life microbiological performance of the BCID2 assay in comparison to the results of standard methods used in routine practice at four tertiary care hospitals.


Subject(s)
Bacteremia , Sepsis , Humans , Blood Culture , Sepsis/diagnosis , Bacteria/genetics , Gram-Negative Bacteria/genetics , Gram-Positive Bacteria , Bacteremia/diagnosis , Bacteremia/microbiology
4.
Int J Infect Dis ; 108: 568-573, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34087488

ABSTRACT

OBJECTIVES: This study aimed to evaluate the performance of FilmArray Pneumonia Panel Plus (FA-PP) for the detection of typical bacterial pathogens in respiratory samples from patients hospitalized in intensive care units (ICUs). METHODS: FA-PP was implemented for clinical use in the microbiology laboratory in March 2020. A retrospective analysis on a consecutive cohort of adult patients hospitalized in ICUs between March 2020 and May 2020 was undertaken. The respiratory samples included sputum, blind bronchoalveolar lavage (BBAL) and protected specimen brush (PSB). Conventional culture and FA-PP were performed in parallel. RESULTS: In total, 147 samples from 92 patients were analysed; 88% had coronavirus disease 2019 (COVID-19). At least one pathogen was detected in 46% (68/147) of samples by FA-PP and 39% (57/147) of samples by culture. The overall percentage agreement between FA-PP and culture results was 98% (93-100%). Bacteria with semi-quantitative FA-PP results ≥105 copies/mL for PSB samples, ≥106 copies/mL for BBAL samples and ≥107 copies/mL for sputum samples reached clinically significant thresholds for growth in 90%, 100% and 91% of cultures, respectively. FA-PP detected resistance markers, including mecA/C, blaCTX-M and blaVIM. The median turnaround time was significantly shorter for FA-PP than for culture. CONCLUSIONS: FA-PP may constitute a faster approach to the diagnosis of bacterial pneumonia in patients hospitalized in ICUs.


Subject(s)
COVID-19 , Pneumonia, Bacterial , Pneumonia , Adult , Bacteria , Humans , Intensive Care Units , Pneumonia, Bacterial/diagnosis , Retrospective Studies , SARS-CoV-2
5.
Diagn Microbiol Infect Dis ; 99(1): 115183, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33069002

ABSTRACT

The FilmArray® Pneumonia Plus (FA-PP) panel can provide rapid identifications and semiquantitative results for many pathogens. We performed a prospective single-center study in 43 critically ill patients with coronavirus disease 2019 (COVID-19) in which we performed 96 FA-PP tests and cultures of blind bronchoalveolar lavage (BBAL). FA-PP detected 1 or more pathogens in 32% (31/96 of samples), whereas culture methods detected at least 1 pathogen in 35% (34/96 of samples). The most prevalent bacteria detected were Pseudomonas aeruginosa (n = 14) and Staphylococcus aureus (n = 11) on both FA-PP and culture. The FA-PP results from BBAL in critically ill patients with COVID-19 were consistent with bacterial culture findings for bacteria present in the FA-PP panel, showing sensitivity, specificity, and positive and negative predictive value of 95%, 99%, 82%, and 100%, respectively. Median turnaround time for FA-PP was 5.5 h, which was significantly shorter than for standard culture (26 h) and antimicrobial susceptibility testing results (57 h).


Subject(s)
Bacteria/isolation & purification , Bacteriological Techniques/methods , COVID-19/complications , Multiplex Polymerase Chain Reaction/methods , Pneumonia, Bacterial/diagnosis , Aged , Bacteria/classification , Bacteria/genetics , Bronchoalveolar Lavage Fluid/microbiology , Critical Illness , Female , Humans , Male , Middle Aged , Pneumonia, Bacterial/microbiology , SARS-CoV-2 , Sensitivity and Specificity , Time Factors
6.
J Clin Microbiol ; 58(11)2020 10 21.
Article in English | MEDLINE | ID: mdl-32878954

ABSTRACT

The worldwide emergence and spread of antimicrobial resistance in Gram-negative bacteria are severely limiting therapeutic options and thus constitute a major public health threat. The timely accurate detection of carbapenemase producers and the determination of carbapenemase class according to the Ambler classification can guide antimicrobial therapy and facilitate infection control measures. A modified version of the carbapenemase inactivation method (CIM), mCIM, was described and approved by the CLSI in 2017. We evaluated the performance of a faster new mCIM-based assay, mCIMplus, which can detect carbapenemase activity within 8 h and characterize the carbapenemase according to the Ambler classification in 20 h. A panel of 137 isolates producing carbapenemases (GES, IMP, KPC, NDM, OXA-48, OXA-48-like, and VIM enzymes) and 22 non-carbapenemase-producing isolates was used to evaluate the performance of mCIMplus. We evaluated the detection of carbapenemase activity at 8 and 20 h. Carbapenemase class was determined, with specific inhibitors, at 20 h. The sensitivities of mCIMplus were 99.3% at 8 h and 98.5% at 20 h. Its specificity was 100% regardless of culture time. Based on a decision algorithm, this test successfully identified the carbapenemase class for 98.4% of the tested isolates (127/129). Characterization was correct for 100, 95, and 100% of Ambler class A, B, and D isolates, respectively. This test can, therefore, be used to detect carbapenemase activity within 8 h and to determine carbapenemase class within 20 h. It constitutes a very affordable (<€1 per isolate) and reliable technique requiring only basic laboratory equipment.


Subject(s)
Bacterial Proteins , beta-Lactamases , Anti-Bacterial Agents/pharmacology , Carbapenems/pharmacology , Humans , beta-Lactamases/genetics
7.
Euro Surveill ; 24(36)2019 Sep.
Article in English | MEDLINE | ID: mdl-31507264

ABSTRACT

We report two cases of multidrug-resistant Neisseria gonorrhoeae urogenital infection with ceftriaxone resistance in a heterosexual couple in south-western France who were successfully treated with a single, high dose of intramuscular ceftriaxone (1 g). Whole genome sequencing of isolate F91 identified MLST13871, NG-MAST1086, NG-STAR233. Patient history revealed the isolate F91 was most likely acquired during a trip to Cambodia and belongs to the successful multidrug-resistant FC428 Asian clone.


Subject(s)
Gonorrhea/diagnosis , Neisseria gonorrhoeae/genetics , Neisseria gonorrhoeae/isolation & purification , Anti-Bacterial Agents/therapeutic use , Azithromycin/therapeutic use , Back Pain/etiology , Cambodia , Ceftriaxone/therapeutic use , Drug Resistance, Multiple, Bacterial , Dysuria/etiology , France , Gonorrhea/drug therapy , Heterosexuality , Humans , Male , Microbial Sensitivity Tests , Multilocus Sequence Typing , Neisseria gonorrhoeae/drug effects , Nucleic Acid Amplification Techniques , Travel , Treatment Outcome , Urethritis/drug therapy , Urethritis/microbiology , Whole Genome Sequencing
SELECTION OF CITATIONS