Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bull Exp Biol Med ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38960959

ABSTRACT

We present the results of a pilot study demonstrating the feasibility of non-invasive non-thermal disintegration of human mucinous carcinoma of the breast ex vivo using sequences of high-intensity focused ultrasound pulses in boiling histotripsy regimen. The target volume was sonicated by focusing ultrasound pulses (n=20) of 1.5 MHz frequency, 10-msec duration and 1-sec pulse repetition period, 517 W acoustic power within the pulse, and 103 MPa shock front amplitude at the focus into each node of a volumetric grid 4×4×1 mm. Sonication was visualized and controlled using B-mode ultrasound imaging, total time of the treatment was 21 min. Histological hematoxylin and eosin and Masson's trichrome staining revealed the absence of tumor elements in the treated region confirming destruction of cancer cells and their nuclei after boiling histotripsy procedure.

2.
Ultrasonics ; 133: 107029, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37207594

ABSTRACT

Focused ultrasound technologies are of growing interest for noninvasive ablation of localized prostate cancer (PCa). Here we present the results of the first case study evaluating the feasibility of non-thermal mechanical ablation of human prostate adenocarcinoma tissue using the boiling histotripsy (BH) method on ex vivo tissue. High intensity focused ultrasound field was generated using a 1.5-MHz custom-made transducer with nominal F#=0.75. A sonication protocol of 734 W acoustic power, 10-ms long BH-pulses, 30 pulses per focal spot, 1 % duty cycle, and 1 mm distance between single foci was tested in an ex vivo human prostate tissue sample containing PCa. The protocol used here has been successfully applied in the previous BH studies for mechanical disintegration of ex vivo prostatic human tissue with benign hyperplasia. BH treatment was monitored using B-mode ultrasound. Post-treatment histologic analysis demonstrated BH produced liquefaction of the targeted tissue volume. BH treated benign prostate parenchyma and PCa had similar tissue fractionation into subcellular fragments. The results of the study demonstrated that PCa tumor tissue can be mechanically ablated using the BH method. Further studies will aim on optimizing protocol parameters to accelerate treatment while maintaining complete destruction of the targeted tissue volume into subcellular debris.


Subject(s)
Adenocarcinoma , High-Intensity Focused Ultrasound Ablation , Prostatic Neoplasms , Male , Humans , High-Intensity Focused Ultrasound Ablation/methods , Prostate/diagnostic imaging , Prostate/surgery , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Ultrasonography , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...