Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 14(11)2024 May 31.
Article in English | MEDLINE | ID: mdl-38893697

ABSTRACT

CBCT (cone beam computed tomography) is an imaging investigation that provides three-dimensional (3D) images of craniofacial structures. The purpose of this study is to determine the mechanical behavior of an orthodontic system where the lingual treatment technique was used in a 25-year-old female patient from whom a set of CBCT scans was used. CBCT images were processed through software programs such as Invesalius, Geomagic, and Solid Works, to create models containing virtual solids. These models were then imported into Ansys Workbench 2019 R3 (a finite element method software program) for successive simulations to generate displacement maps, deformations, stress distributions, and diagrams. We observed that in the lingual technique, the lowest force occurring on the maxillary teeth is at 1.1, while the highest force appears at 2.3. In the mandible, the lowest force occurs at 4.6, and the highest force at 3.1. The values of the forces and the results of the finite element method can represent a basis for the innovation of new orthodontic springs and also of bracket elements. Thus, by using new technologies, orthodontic practice can be significantly improved for the benefit of patients. Other virtual methods and techniques can be used in future studies, including the application of virtual reality for orthodontic diagnosis.

2.
J Funct Biomater ; 15(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38667543

ABSTRACT

The possibility of dental pulp damage during dental procedures is well known. According to studies, during finishing and polishing without cooling, temperatures of up to 140 °C or more can be generated. There are many studies that have analysed the influence of the finishing and polishing of fillings on the mechanical parameters, but the analysis of thermal parameters has led to uncertain results due to the difficulty of performing this in vivo. Background: We set out to conduct a study, using the finite element method, to determine the extent to which the type of class II cavity and the volume of the composite filling influence the duration of heat transfer to the pulp during finishing and polishing without cooling. Materials and Methods: A virtual model of an upper primary molar was used, with a caries process located on the distal aspect, in which four types of cavities were digitally prepared: direct access, horizontal slot, vertical slot and occlusal-proximal. All four cavity types were filled using a Filtek Supreme XT nanocomposite. Results: The study showed that the filling volume almost inversely proportionally influences the time at which the dental pulp reaches the critical temperature of irreversible damage. The lowest duration occurred in occlusal-distal restorations and the highest in direct access restorations. Conclusions: based on the results of the study, a working protocol can be issued so that finishing and polishing restorations without cooling are safe for pulpal health.

3.
J Funct Biomater ; 14(7)2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37504849

ABSTRACT

The restoration of class II cavities is predominantly carried out with composite materials. Due to the high failure rate in restoring this type of cavity, composite materials with much-improved properties and new application techniques have been promoted. The study aimed to analyze the mechanical behavior of several topical composite materials (nanocomposites, nanohybrids and ormocer) using different application techniques. In a lower second molar, a class II occlusal cavity was prepared. As filling materials, we used the following combinations: Admira Fusion and Admira Fusion Flow, Grandio and Grandio Flow, Filtek Supreme XT and Filtek Supreme Flow. These were applied using a snow plow, injection molded and Bichacho techniques. Three-dimensional scanning of the molar with the prepared cavity was performed, and then scanning of each layer of added composite material was performed, obtaining three-dimensional models. The virtual molar models were analyzed with software specific to the finite element analysis method, where their physical-mechanical properties were entered and assigned to the components of the virtual molar. Simulations at high forces specific to bruxism were then carried out and analyzed, and compared. The values of displacements and strain, for all six analyzed situations, are relatively small (range from 5.25 × 10-6-3.21 × 10-5 for displacement, 6.22 × 10-3-4.34 × 10-3 for strain), which validates all three methods and the materials used. As far as the stress values are concerned, they are similar for all methods (250-300 MPa), except for the snow plow and injection-molded techniques using Grandio and Grandio Flow composites, where the maximum von Mises stress value was more than double (approximately 700 MPa). When using the combination of Grandio and Grandio Flow materials, the 1 mm thickness of the fluid composite layer was found to have a major influence on occlusal forces damping as opposed to 0.5 mm. Therefore, the Bichacho technique is indicated at the expense of the snow plow and injection-molded techniques. The composite materials used by us in this study are state-of-the-art, with clear indications for restoring cavities resulting from the treatment of carious lesions. However, their association and application technique in the case of Class II cavities is of clinical importance for resistance to masticatory forces.

4.
Diagnostics (Basel) ; 13(9)2023 Apr 27.
Article in English | MEDLINE | ID: mdl-37174958

ABSTRACT

The finite element method (FEM) is a computational method that can solve all biomechanical problems, including the field of orthodontics. The purpose of this virtual experimental study is to determine the behavior of a real orthodontic system subjected to different systems of loads. To analyze the real orthodontic system, we studied the case of a 21-year-old female patient. We used the InVesalius program, which can transform a set of DICOM-type images taken from cone beam computed tomography (CBCT) into three-dimensional structures. These structures were edited, modified, completed, and analyzed from a geometric point of view with the help of the Geomagic software. The final result of these operations must be a three-dimensional model made up of perfectly closed surfaces so that they can be transformed into virtual solids. The model consisting of perfectly closed surfaces is loaded into computer-aided design (CAD) programs. Bracket and tube components, as well as orthodontic wires, can be added to these models, similar to the analyzed patient's tissues. When the model is complete and geometrically correct, it is exported to a program that uses FEM, such as Ansys Workbench. The simulation was performed for the forces of 0.5, 0.6, 0.7, 0.8, 0.9, and 1 N. The intention was to determine the behavior of the entire orthodontic system for these force values. After running the simulations, result maps were obtained that were composed of displacement, strain, and stress diagrams. It was also found that, in addition to the known rigidity, the orthodontic system has some elasticity due to the orthodontic wires, as well as the periodontal ligaments. Thus, a virtual analysis study can be carried out starting from a real patient with pre-treatment CBCT images and the virtual models of the bracket and tube elements and of the orthodontic wires.

5.
Article in English | MEDLINE | ID: mdl-35897304

ABSTRACT

The purpose of this study was to show the improved outcomes of restoring endodontically treated teeth with fiberglass posts compared to restorations using metal posts. In our study, we used the Finite Element Method (FEM), which is based on the principle that a physical model that supports a given load distributes the stress throughout its volume. We sought to assess what stress results in a tooth when it is restored using a fiberglass post compared to restoration using a metal post. The finite element analysis showed that a system consisting of a tooth with a fiberglass post is more stable in terms of the maximum stress than a system consisting of a tooth with a metal post. The maximum displacements and deformations were obtained in the case of a canine restored with a fiberglass post, which showed that this system had a high elasticity, therefore, higher strength than a canine restored with a metal post, which had high rigidity.


Subject(s)
Post and Core Technique , Tooth, Nonvital , Composite Resins , Finite Element Analysis , Glass , Humans , Tooth, Nonvital/therapy
6.
Diagnostics (Basel) ; 12(5)2022 May 23.
Article in English | MEDLINE | ID: mdl-35626452

ABSTRACT

Cone beam computed tomography (CBCT) is a modern imaging technique that uses X-rays to investigate the structures of the dento-maxillary apparatus and obtain detailed images of those structures. The aim of this study was to determine a functional mathematical model able to evaluate the elastic force intensity on each bracket and tube type element and the ways in which those components act on the orthodontic system being used. To analyze a real orthodontic system, we studied the case of a 13-year-old female patient. To transfer geometric information from tomographic images, we used the InVesalius software. This software can generate three-dimensional reconstructions based on sequences and files in the DICOM format and was purchased from CBCT equipment. We analyzed and processed the geometries of the converted tissues in InVesalius using the Geomagic software. After using the Geomagic software, we exported the resulting model to the SolidWorks software used in computer-aided design. In this software, the model is transformed into a virtual solid. After making the geometric model, we analyzed the model using the Ansys Workbench software, which incorporates finite element analysis techniques. Following the simulations, we obtained result maps, which showed the complete mechanical behavior of the analyzed structures.

7.
Curr Health Sci J ; 46(1): 31-38, 2020.
Article in English | MEDLINE | ID: mdl-32637163

ABSTRACT

The objective of this study was to obtain a virtual biomechanical three dimensional model of the human eye though a multidisciplinary collaboration between researchers in various medical and informational fields in order to reach a better understanding of the optical performance of the healthy and diseased eye. MATERIAL AND METHOD: In order to obtain the virtual model, we analyzed the CT and MRI images of six patients, aged between 21 and 80 years old, dating from February 2013 until January 2019. These scans totalized 4226 images. We selected to use for the construction of the model the CT images of a male patient of 54 years old. In Vesalius and Geomagic for SolidWorks programs were used. RESULTS: Based on the CT images analysis and using the above mentioned programs, we created a virtual model of the human skull in which the orbit is located, including the eye globe and the extraocular muscles. The SolidWorks virtual model allows the attachment of materials with real properties of the eye tissues. This model can be used in various simulations for the healthy and diseased eye. CONCLUSIONS: The biomechanical eye model of the eye was created based on a "in vivo" eye model. As the SolidWorks format enables using materials with identical properties to those of the human eyeball, this virtual model can provide very realistic eye simulations.

SELECTION OF CITATIONS
SEARCH DETAIL
...