Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
2.
Clin Imaging ; 110: 110170, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38696998

ABSTRACT

INTRODUCTION: In patients with atrial fibrillation (AF), up to one third have recurrence after a first catheter ablation (CA). Epicardial adipose tissue (EAT) has been considered to be closely related to AF, with a potential role in its recurrence. We aimed to evaluate the association between the volume of EAT measured by cardiac computed tomography (CT) and AF recurrence after CA. METHODS: Consecutive AF patients underwent a standardized cardiac CT protocol for quantification of EAT, thoracic adipose volume (TAV) and left atrium (LA) volume before CA. An appropriate cut-off of EAT was determined and risk recurrence was estimated. RESULTS: 305 patients (63.6 % male, mean age 57.5 years, 28.2 % persistent AF) were followed for 24 months; 23 % had AF recurrence at 2-year mark, which was associated with higher EAT (p = 0.037) and LAV (p < 0.001). Persistent AF was associated with higher EAT volumes (p = 0.010), TAV (p = 0.003) and LA volumes (p < 0.001). EAT was predictive of AF recurrence (p = 0.044). After determining a cut-off of 92 cm3, survival analysis revealed that EAT volumes > 92 cm3 showed higher recurrence rates at earlier time points after the index ablation procedure (p = 0.006), with a HR of 1.95 (p = 0.008) of AF recurrence at 2-year. After multivariate adjustment, EAT > 92 cm3 remained predictive of AF recurrence (p = 0.028). CONCLUSION: The volume of EAT measured by cardiac CT can predict recurrence of AF after ablation, with a volume above 92 cm3 yielding almost twice the risk of arrhythmia recurrence in the first two years following CA. Higher EAT and TAV are also associated with persistent AF.


Subject(s)
Adipose Tissue , Atrial Fibrillation , Catheter Ablation , Pericardium , Recurrence , Tomography, X-Ray Computed , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Male , Female , Adipose Tissue/diagnostic imaging , Middle Aged , Catheter Ablation/methods , Pericardium/diagnostic imaging , Pericardium/pathology , Tomography, X-Ray Computed/methods , Predictive Value of Tests , Aged , Treatment Outcome , Epicardial Adipose Tissue
3.
Int J Cardiol Heart Vasc ; 51: 101369, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38420510

ABSTRACT

Introduction: Atrial fibrillation (AF) ablation represents a safe and effective procedure to restore sinus rhythm. The idea that post-procedural AF episodes - during the blanking period - are not considered treatment failure has been increasingly challenged. The E-Patch, a single-use adhesive electrode, facilitates extended continuous ECG monitoring for 120 h. This pilot study aims to assess the effectiveness of this ambulatory monitoring device and investigate whether very-early AF recurrence correlates with delayed blanking period ablation outcomes. Methods: We conducted a single-center, prospective, longitudinal study, including consecutive post-ablation patients monitored with the E-patch. The ability of the device to continuously record was analyzed, as well as the occurrence of AF episodes during external 7-day loop-recorder in the 2nd-month post-ablation. Results: We included 40 patients, median age 62 years (IQR 56-70). E-Patch monitoring was obtained for a median of 118 h (IQR 112-120), with no discomfort nor interpretation artefacts. Very-early AF recurrence was detected in 11 (27.5 %) patients, with a median AF burden of 7 % (IQR 6 %-33 %). Late-blanking period AF was detected in 13 (33 %) of the external 7-day loop recordings. Of the 11 patients that had very-early AF recurrence, 10 (91 %) had late-blanking AF. Very-early AF detection showed 77 % (95 % CI 64 %-90 %) sensitivity and 96 % (95 % CI 90-100 %) specificity in predicting late-blanking AF, with a non-parametric ROC curve AUC of 0.903 (95 % 0.797--1.0). Conclusion: The E-Patch was able to detect very-early AF during an extended period. Very-early AF detection emerges as a predictor of AF recurrence during the late blanking period post-ablation.

4.
J Interv Card Electrophysiol ; 67(3): 479-492, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37414922

ABSTRACT

BACKGROUND: Impaired left atrial (LA) strain predicts atrial fibrillation (AF) recurrence after catheter ablation (CA), but currently there is no cut-off to guide patient selection for CA. Integrated backscatter (IBS) is a promising tool for noninvasive quantification of myocardial fibrosis. The aim of this study was to compare LA strain and IBS between paroxysmal, persistent, and long-standing persistent AF and evaluate their association with AF recurrence after CA. METHODS: Analysis of consecutive patients with symptomatic paroxysmal and persistent AF who underwent CA. LA phasic strain, strain rate and IBS were assessed by two-dimensional speckle-tracking at baseline. RESULTS: We analyzed 78 patients, 31% with persistent AF (46% long-standing AF), 65% male, mean age 59 ± 14 years, who underwent CA and were followed-up for 12 months. AF recurrence occurred in 22 (28%) patients. LA phasic strain parameters were significantly impaired in patients with AF recurrence and were independent predictors of AF recurrence in a multivariable analysis. LA reservoir strain (LASr) < 18% predicted AF recurrence with 86% sensitivity and 71% specificity, with a higher predictive power compared to LA volume index (LAVI). LASr < 22% in paroxysmal AF and LASr < 12% in persistent AF correlated with AF recurrence. Increased IBS was a predictor of AF recurrence in patients with paroxysmal AF. CONCLUSION: LA phasic strain parameters were predictors of AF recurrence after CA, independently of LAVI and AF subtype. LASr < 18% showed a higher predictive power compared to LAVI. Further studies are needed to investigate the role of IBS as a predictor of AF recurrence.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Echocardiography/methods , Treatment Outcome , Predictive Value of Tests , Heart Atria/surgery , Catheter Ablation/methods , Recurrence
5.
Front Cardiovasc Med ; 10: 1309900, 2023.
Article in English | MEDLINE | ID: mdl-38075955

ABSTRACT

Background: An ablation catheter and a circular mapping catheter requiring a double transeptal puncture (TSP) for left atrial access have been conventionally used for atrial fibrillation (AF) ablation. Recently, different operators have combined a single transseptal puncture technique with 3D high-density mapping catheters for pulmonary vein isolation (PVI). Objective: This study aims to compare two strategies, single vs. double TSP, regarding the duration of the procedure, radiation time, complication rates, and outcomes. Methods: Retrospective analysis of a large cohort of consecutive patients that underwent first PVI with radiofrequency energy (RF), using a point-by-point strategy, with a 3D mapping system, either with single or double TSP, according to the operator's choice. Results: 285 patients with a mean age of 59.5 ± 11.6 years (36.5% female, 67.7% paroxysmal AF) underwent a point-by-point catheter ablation with RF between July 2015 and March 2020. The mean CHA2DS2-VASc score was 1.7 ± 1.3. Single TSP was performed in 115 (40.3%) patients and double TSP in 170 (59.6%). The operator's experience (≥5 years of AF ablation procedures) was equally distributed among the two groups. The average procedure time (133 ± 31.7 min vs. 123 ± 35.5 min, for single and double TSP, respectively) did reach a statistical difference between both groups (p = 0.008), but there was a substantial advantage regarding fluoroscopy time (13 ± 6.3 min vs. 19 ± 9.1 min, for single and double TSP, respectively; p < 0.001). Acute major complications present similar rates in both groups (2.6% vs. 2.3%, p = 0.799). At the 2-year follow-up, both groups had a similar sinus rhythm maintenance rate (76.5% vs. 78.8%, p = 0.646). Conclusion: A simplified single-TSP technique using high-density multi-electrode 3D mapping is a safe and highly successful option for AF ablation. This approach yields a substantial reduction in fluoroscopy time, with the potential to avoid acute complications, compared to a conventional double-TSP strategy.

6.
J Innov Card Rhythm Manag ; 14(9): 5576-5581, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37781719

ABSTRACT

The heart failure risk status (HFRS) is a validated dynamic tool for risk score prediction, based on the TriageHF™ algorithm (Medtronic, Minneapolis, MN, USA), for the occurrence of a heart failure (HF) event in the 30 days following a remote monitoring (RM) transmission. The aim of this study was to evaluate the accuracy of the HFRS in predicting an unplanned hospital admission due to HF decompensation in a real-world cohort of patients submitted to cardiac resynchronization therapy (CRT). We conducted a single-center review of a cohort of 40 consecutive HF patients, under RM, with CRT devices using the HFRS of the TriageHF™ algorithm. The correlation of the HFRS with hospital admissions was analyzed. During a mean follow-up of 36 months, a stepwise increase in the HFRS was significantly associated with a higher risk of HF admission (odds ratio, 12.7; 95% confidence interval, 3.2-51.5; P < .001), and the HFRS was demonstrated to have good discrimination for HF hospitalization, with an area under the receiver-operating characteristic curve of 0.812. The TriageHF™ algorithm effectively predicted HF-related hospitalization in a cohort of CRT patients during long-term RM follow-up, providing a novel clinical pathway to optimize the clinical management of this complex population.

7.
Rev Port Cardiol ; 42(9): 811-812, 2023 09.
Article in English, Portuguese | MEDLINE | ID: mdl-37023980
9.
Cardiol Rev ; 2023 Mar 08.
Article in English | MEDLINE | ID: mdl-36883833

ABSTRACT

This study reviews the published data comparing the efficacy and safety of apical and septal right ventricle defibrillator lead positioning at 1-year follow-up. Systemic research on Medline (PubMed), ClinicalTrials.gov, and Embase was performed using the keywords "septal defibrillation," "apical defibrillation," "site defibrillation," and "defibrillation lead placement," including implantable cardioverter-defibrillator and cardiac resynchronization therapy devices. Comparisons between apical and septal position were performed regarding R-wave amplitude, pacing threshold at a pulse width of 0.5 ms, pacing and shock lead impedance, suboptimal lead performance, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter, readmissions due to heart failure and mortality rates. A total of 5 studies comprising 1438 patients were included in the analysis. Mean age was 64.5 years, 76.9% were male, with a median LVEF of 27.8%, ischemic etiology in 51.1%, and a mean follow-up period of 26.5 months. The apical lead placement was performed in 743 patients and septal lead placement in 690 patients. Comparing the 2 placement sites, no significant differences were found regarding R-wave amplitude, lead impedance, suboptimal lead performance, LVEF, left ventricular end-diastolic diameter, and mortality rate at 1-year follow-up. Pacing threshold values favored septal defibrillator lead placement (P = 0.003), as well as shock impedance (P = 0.009) and readmissions due to heart failure (P = 0.02). Among patients receiving a defibrillator lead, only pacing threshold, shock lead impedance, and readmission due to heart failure showed results favoring septal lead placement. Therefore, generally, the right ventricle lead placement does not appear to be of major importance.

10.
Rev Port Cardiol ; 42(4): 363-370, 2023 04.
Article in English, Portuguese | MEDLINE | ID: mdl-36634763

ABSTRACT

BACKGROUND: Cryoballoon ablation (CBA) for pulmonary vein isolation (PVI) has been growing as an alternative technique, not only in patients with paroxysmal atrial fibrillation (PAF) but also in persistent atrial fibrillation (AF). Cryoballoon ablation has demonstrated encouraging acute and mid-term results. However, data on long-term follow-up of CB-based PVI are scarce. OBJECTIVE: We sought to examine efficacy, safety, and long-term outcomes of CBA in PAF and persistent AF in four Portuguese centers. METHODS: All patients that were treated with the cryoballoon catheter according to routine practices with a second-generation 28-mm CB in four centers were included. This was a retrospective, non-randomized analysis. Patients were followed-up for >12 months and freedom from atrial arrhythmias (AA) was evaluated at the end of follow-up. RESULTS: Four hundred and six patients (57.7±12.4 years, 66% men) participated. AF was paroxysmal in 326 patients (80.2%) and persistent in 80 (19.7%). The mean procedure time duration was 107.7±50.9 min, and the fluoroscopy time was 19.5±9.7 min. Procedural/periprocedural complications occurred in 30 cases (7.3%), being transient phrenic nerve palsy the most frequent incident (2 out of 3 complications). Anatomic variations of the PV were present in 16.1% of cases. At a mean follow-up of 22.0±15.0 months, 310 patients (76.3%) remained in stable sinus rhythm, with at least one AF episode recurrence documented in 98 cases (24.1%). The recurrence rate was 20.5% in the PAF group and 37.8% in the persistent AF group. CONCLUSION: In this multicenter experience, a single CBA procedure resulted in 75.9% freedom from AF at a 22-month follow-up. This technique was demonstrated to be a safe and effective option in experienced centers for the treatment of PAF and PersAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Male , Humans , Female , Atrial Fibrillation/complications , Portugal , Treatment Outcome , Retrospective Studies , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
11.
Eur Heart J Case Rep ; 7(1): ytad010, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36694873

ABSTRACT

Background: Risk stratification for sudden cardiac death (SCD) is a key factor in the management of patients with hypertrophic cardiomyopathy (HCM). Cardiac magnetic resonance (CMR) has a unique role in the evaluation of HCM and offers superior diagnostic and prognostic information to assess the indication for a prophylactic implantable cardioverter-defibrillator (ICD). Case summary: A 39-year-old patient with non-obstructive HCM with a low ESC HCM Risk-SCD score underwent a CMR revealing a left ventricular apical aneurysm and extensive late gadolinium enhancement; a prophylactic ICD was thus implanted. A month later, the patient was admitted in refractory electrical storm with over 50 appropriate ICD shocks due to sustained ventricular tachycardia. Despite anti-arrhythmic therapy and mechanical ventilation, the evolution was unfavourable with haemodynamic instability; veno-arterial extracorporeal membrane oxygenation was implanted. The patient was submitted to CMR-guided epicardial VT catheter ablation with complications of LV thrombus and severe pericardial effusion. Discussion: This case details the complex risk stratification for SCD in patients with HCM, highlighting the important role of CMR in the integrated approach to risk stratification.

13.
Int J Cardiol Heart Vasc ; 43: 101138, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36275421

ABSTRACT

Objective: This study aimed to assess whether atrial fibrillation (AF) occurrence or its corresponding daily mean burden (in minutes/day) during the mid to late blanking period after pulmonary vein isolation (PVI), predicts AF recurrence. Methods: Analysis of consecutive first PVI ablation patients undergoing prolonged electrocardiogram (ECG) monitoring during the second and third months after PVI. The clinical variables, total AF burden, and their relationship with time to recurrence were studied. Results: 477 patients with a mean age of 56.9 (SD = 12.3) years (63.7 % male; 71.7 % paroxysmal AF), from which 317 (66.5 %) had an external event recorder between 30 and 90 days after ablation. Median follow-up of 16.0 (P 25:12.0: P 75:33.0) months, 177 (37 %) patients had an AF recurrence, with 106 (22.2 %) having the first episode after 12 months of follow-up. In the group of patients with an event recorder, 80 (25.2 %) had AF documented during the blanking period. Multivariable analysis showed that AF during the blanking period was associated with a 4-fold higher risk of recurrence (HR: 3.98; 95 %CI: 2.95-5.37), and, compared to patients in sinus rhythm, those with an AF burden ≥ 23 min/day had an approximately 7-fold higher risk of recurrence (HR estimate: 6.79; 95 %CI: 4.56-10.10). Conclusions: The probability of experiencing AF recurrence can be predicted by atrial tachyarrhythmia episodes during the second and third months after PVI. Atrial arrhythmias burden > 23 min/day has a high predictive ability for recurrence.

14.
Rev Port Cardiol ; 41(8): 663-664, 2022 Aug.
Article in English, Portuguese | MEDLINE | ID: mdl-36073264
15.
Geriatrics (Basel) ; 7(1)2022 Feb 17.
Article in English | MEDLINE | ID: mdl-35200525

ABSTRACT

Atrial fibrillation (AF) is commonly associated with advanced age and the presence of multiple, concomitant acute and chronic health conditions, placing this population at high risk for serious therapeutic side effects. Nonvitamin K antagonist oral anticoagulants (NOACs) are increasingly used for stroke prevention in patients with atrial fibrillation. The purpose of this study was to investigate the effectiveness and safety of NOAC in a group at high risk of bleeding complications, in a real-world setting. We conducted a retrospective analysis of a high-risk cohort of 418 patients (pts) followed-up in our anticoagulation unit; data on patient characteristics, anticoagulation treatment, and bleeding and thrombotic complications were evaluated. The population had a median age of 77.8 ± 10.3 years and the mean CHA2DS2-VASc score was 3.85 (SD ± 1.4). Overall, 289 (69.1%) were ≥75 years old. During a mean follow-up time of 51.2 ± 35.7 months, we observed a rate of any bleeding of 7, a clinically relevant non-major bleeding rate of 4.8, a major bleeding rate of 2.2, a stroke rate of 1.6, and a rate of thrombotic events of 0.28 per 100 patient-years. There were 59 hospitalizations due to any cause (14.1%) and 36 (8.6%) deaths (one due to ischemic stroke). A structured follow-up, with judicious prescribing and drug compliance, may contribute to preventing potential complications.

16.
Heart Lung ; 51: 82-86, 2022.
Article in English | MEDLINE | ID: mdl-34775159

ABSTRACT

BACKGROUND: Endocardial left ventricular pacing is an alternative technique used in cardiac resynchronization therapy (CRT), when placement of a left ventricular lead is not possible via the coronary sinus or in non-responders to conventional CRT. OBJECTIVES: To review the evidence regarding the efficacy and safety of endocardial left ventricular pacing. METHODS: Systematic research on Medline (PubMed), ClinicalTrials.gov and Embase with the terms "endocardial left ventricular pacing", "biventricular pacing" or "endocardial left pacing" was performed with the identification of 1038 results. Eleven studies with endocardial left ventricular pacing patients were included, independent of the technique being applied to naïve CRT patients or con non-responders to conventional CRT. The end-point of this analysis was the impact of endocardial left ventricular pacing techniques regarding New York Heart Association (NYHA) functional classification, left ventricular ejection fraction (LVEF) and QRS width, and the occurrence of complications Mean differences (MD) and confidence interval (CI) was used as a measurement of treatment. RESULTS: A total of 560 patients were included, with different techniques used (trans-atrial septal technique, trans-ventricular septal technique and transapical technique). Significant improvement was registered in NYHA class (MD 0.73, CI 0.48-0.98, p<0.00001, I2 = 87%), LVEF (MD -7.63, CI -9.93 - -5.33, p<0.00001, I2 = 69%) and QRS width (MD 29.25, CI 9.99-48.50, p<0.00001, I2 = 91%). Several complications were reported after the procedure, 11 pocket infections, 22 transient ischemic attacks, 18 ischemic strokes, 41 thromboembolic events, among other complications. The mortality rate during the follow-up was 20.54%. CONCLUSION: Left ventricular endocardial pacing is a feasible alternative to conventional CRT, with clinical, electrocardiographic and echocardiogrphic improvement. However, first data regarding this procedure was associated with significant complications rates.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Stroke Volume , Treatment Outcome , Ventricular Function, Left
17.
Rev Port Cardiol (Engl Ed) ; 40(11): 865-873, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34857160

ABSTRACT

INTRODUCTION: Recurrent ventricular tachycardia (VT) episodes have a negative impact on the clinical outcome of implantable cardioverter-defibrillator (ICD) patients. Modification of the arrhythmogenic substrate has been used as a promising approach for treating recurrent VTs. However, there are limited data on long-term follow-up. AIM: To analyze long-term results of VT substrate-based ablation using high-density mapping in patients with severe left ventricular (LV) dysfunction and recurrent appropriate ICD therapy. METHODS: We analyzed 20 patients (15 men, 55% with non-ischemic cardiomyopathy, age 58±15 years, LV ejection fraction 32±5%) and repeated appropriate shocks or arrhythmic storm (>2 shocks/24 h) despite antiarrhythmic drug therapy and optimal heart failure medication. All patients underwent ventricular programmed stimulation (600 ms/S3) to document VT. A sinus rhythm (SR) voltage map was created with a three-dimensional electroanatomic mapping system (CARTO, Biosense Webster, CA) using a PentaRay® high-density mapping catheter (Biosense Webster, CA) to delineate areas of scarred myocardium (ventricular bipolar voltage ≤0.5 mV - dense scar; 0.5-1.5 mV - border zone; ≥1.5 mV - healthy tissue) and to provide high-resolution electrophysiological mapping. Substrate modification included elimination of local abnormal ventricular activities (LAVAs) during SR (fractionated, split, low-amplitude/long-lasting, late potentials, pre-systolic), and linear ablation to obtain scar homogenization and dechanneling. Pace-mapping techniques were used when capture was possible. The LV approach was retrograde in nine cases, transseptal in five and epi-endocardial in four. In two patients ablation was performed inside the right ventricle. RESULTS: LAVAs and scar areas were modified in all patients. Mean procedure duration was 149 min (105-220 min), with radiofrequency ranging from 18 to 70 min (mean 33 min) and mean fluoroscopy time of 15 min. Non-inducibility was achieved in 75% of cases (in four patients with hemodynamic deterioration and an LV assist device, VT inducibility was not performed). There were two cases of pericardial tamponade, drained successfully. During a follow-up of 50±24 months, 65% had no VT recurrences. Among the seven patients with recurrences, three underwent redo ablation and four, with fewer VT episodes, received appropriate ICD therapy. There were five hospital readmissions due to heart failure decompensation, one patient died in the first week after unsuccessful ablation of a VT storm and three died (stroke and pneumonia) >1 year after ablation. CONCLUSION: Catheter ablation based on substrate modification is feasible and safe in patients with frequent VTs and severe LV dysfunction. This approach may be of clinical relevance, with potential long-term benefits in reducing VT burden.


Subject(s)
Cardiomyopathy, Dilated , Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Adult , Aged , Cardiomyopathy, Dilated/therapy , Humans , Male , Middle Aged , Tachycardia, Ventricular/therapy , Treatment Outcome
18.
Int J Cardiol Heart Vasc ; 37: 100906, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34725644

ABSTRACT

AIMS: The present study analysed the patterns of physical activity pre-, during and post-lockdown measures for COVID-19 pandemic in patients with chronic heart failure (CHF) and cardiac implantable electronic devices (CIED) under remote monitoring (RM), and assessed the physical activity patterns during these periods. METHODS: The raw data from 95 patients with CHF (age 67,7 ± 15,1 years, 71,5% male) corresponding to 2238 RM transmissions of the Medtronic Carelink™ network platform was obtained. The physical exercise profiles and the impact of the lockdown measures on the physical behaviour during and after the measures were analysed. According to the level of activity duration in the pre-lockdown, lockdown and post-lockdown periods, the patterns of behaviour were identified (non-recoverees, incomplete recoverees, recoverees and full-recoverees). CONCLUSION: RM of CHF patients with CIED using the Carelink™ network is useful for close follow-up and identification of heart failure risk status variations. After relieving the confinement measures there were two groups of patients that did not recover the previous physical activity levels. Physical inactivity in patients with CHF can have a significant impact on outcomes.

19.
Langmuir ; 37(15): 4493-4503, 2021 Apr 20.
Article in English | MEDLINE | ID: mdl-33826351

ABSTRACT

Perovskite oxide heterostructures have been extensively investigated for their excellent photocatalytic properties. Here, through hybrid density functional theory calculations, we systematically investigate the formation of NaNbO3-NaTaO3 (NBO-NTO) heterostructures. The sequential cations replacement in the superlattices reveals the Nb-Ta ratio range that allows the effective formation of heterostructures, which occurs through a spontaneous polarization mechanism induced by the electrostatic potential discontinuity in the interface. The resulting cation ordering is responsible for the sawtooth-like potential distribution that spatially separates valence and conduction charges and reduces the heterostructure bandgap. The symmetric NBO5/NTO5 junction has the smallest bandgap (2.50 eV) whose transitions are associated with Nb 5dxy orbitals on the interfacial plane. Such a relaxation mechanism provides the heterostructure with anisotropic optical properties and interface absorption peaks closer to the visible light spectrum. The phenomena strongly suggest the use of these heterostructures in photocatalytic reactions, supported by their coherent band-edge alignment with both water splitting and CO2 reforming potentials.

20.
Port J Card Thorac Vasc Surg ; 28(3): 21-24, 2021 Nov 07.
Article in English | MEDLINE | ID: mdl-35333473

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) contributes to increased morbidity and mortality. Pharmacological and percutaneous catheter therapies are unsatisfactory, with potential serious adverse effects. Cox-Maze III/IV surgery, with higher rates of success, has not been widely adopted because of the associated complexity of the procedure. METHODS: We performed a retrospective analysis of the first patients submitted to surgical ablation of AF with occlusion of the left atrial appendage with a totally videothoracoscopic (VATS) approach in our institution. We describe the surgical technique and our results, including duration of surgery, hospital stay, complications and maintenance of sinus rhythm after surgery, at 6, 12 and 18 months of follow-up. RESULTS: We studied 15 patients (ages ranging from 39 to 75 years old; 54,5% female gender). Mean time since the diagnosis of AF was 5,75 years. All had been submitted to prior catheter ablation (mean of 2 attempts). Mean diameter and volume of the left atrium was 42 mm (M-mode) and 70 ml (43 ml/m2), respectively. Mean duration of surgery was 2 hours and 22 minutes. In one patient we had to convert the surgery to median sternotomy. Mean hospital stay was 4,8 days. Mean time of follow-up was 12 months. During follow-up, 91%, 90% and 80% of the patients were in sinus rhythm at 6, 12 and 18 months, respectively. CONCLUSION: This surgical approach represents a real benefit for those patients with multiple attempts of catheter ablation without success. However, a larger sample of patients with a longer period of follow-up is necessary for further conclusions.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Adult , Aged , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...